GB/T 3682.2-2018 English PDFUS$359.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 3682.2-2018: Plastics -- Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics -- Part 2: Method for materials sensitive to time-temperature history and/or moisture Status: Valid
Basic dataStandard ID: GB/T 3682.2-2018 (GB/T3682.2-2018)Description (Translated English): Plastics -- Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics -- Part 2: Method for materials sensitive to time-temperature history and/or moisture Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: G31 Classification of International Standard: 83.080.20 Word Count Estimation: 18,156 Date of Issue: 2018-03-15 Date of Implementation: 2018-10-01 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB/T 3682.2-2018: Plastics -- Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics -- Part 2: Method for materials sensitive to time-temperature history and/or moisture---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Plastics--Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics--Part 2. Method for materials sensitive to time-temperature history and/or moisture ICS 83.080.20 G31 National Standards of People's Republic of China Plastic Thermoplastic Melt Mass Flow Rate (MFR) And melt volume flow rate (MVR) determination Part 2. Time-Temperature History and/or Humidity Sensitive materials test methods Part 2. Methodformaterialssensitivetotime-temperaturehistoryand/ormoisture (ISO 1133-2.2011, MOD) 2018-03-15 Release.2018-10-01 Implementation General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China China National Standardization Administration released ForewordGB/T 3682 "Determination of Melt Mass Flow Rate (MFR) and Melt Volume Flow Rate (MVR) of Plastic Thermoplastics" by The following two parts are composed. --- Part 1. Standard methods; --- Part 2. Test methods for time-temperature history and/or humidity sensitive materials. This part is part 2 of GB/T 3682. This section was drafted in accordance with the rules given in GB/T 1.1-2009. This section uses the redrafted method to modify the use of international standards ISO 1133-2.2011 "plastic thermoplastic melt flow rate Determination of (MFR) and melt volume flow rate (MVR) - Part 2. Tests on time-temperature history and/or humidity-sensitive materials Inspection method." The technical differences between this part and ISO 1133-2.2011 and its causes are as follows. --- On the normative reference documents, this section made adjustments with technical differences to adapt to China's technical conditions, adjust the situation The focus is reflected in Chapter 2, “Normative References,” and the specific adjustments are as follows. ● Replace ISO 1628-1.1998 with GB/T 1632.1-2008 modified to adopt international standards; ● Replace ISO 1133-1.2011 with GB/T 3682.1-2018 modified to adopt international standards; ● Replace GB/T 12006.1-2009 with international standards instead of ISO 307.2007; ● Replace ISO 15512.1999 with GB/T 12006.2-2009 modified to adopt international standards. This part is proposed by China Petroleum and Chemical Industry Federation. This part is under the jurisdiction of the General Methods and Products Section of the National Plastics Standardization Technical Committee (SAC/TC15/SC4). The main drafting units of this section. China Blue Chenguang Chengdu Testing Technology Co., Ltd., China Bluestar (Group) Co., Ltd., Chengde City, Gold Construction Inspection Instrument Co., Ltd., Shandong Daun Polymer Materials Co., Ltd., China National Petroleum Corporation Daqing Chemical Research Center, Beijing Huasu Chenguang Technology Co., Ltd. The main drafters of this section. Xie Peng, Zhao Lei, Zhang Huaizhi, Peng Bin, Zheng Ning, Ren Yufeng, Chen Minjian, Chen Hongyuan.IntroductionThe methods provided in this section apply to materials whose rheological behavior is time-temperature history and/or humidity sensitive during testing. GB/T 3682.1-2018 does not specify the test conditions for such materials. The precision of the test data obtained cannot meet the requirements (ie at least Equivalent to the precision level of the data obtained using the GB/T 3682.1-2018 test stability material). This section and humidity sensitive materials For relevance. The main difference between this part and GB/T 3682.1-2018 is the temperature tolerance, time line, sample size and pretreatment specified in this part. Strict, with better repeatability and reproducibility, test results have better precision. Rheological behavior MVR measurement of thermoplastic materials affected by hydrolysis and condensation phenomena, the precision of which is often severely affected by the following factors. --- Moisture content and sample conditioning; --- Sample processing; --- Weak temperature difference, that is, the temperature within the barrel changes with position and time; --- The total time of the material at the test temperature; --- sample volume; --- Sample pattern (shape and size - particles, powder, small pieces, etc.); --- Instrument cleaning. In order to obtain accurate, repeatable and reproducible results, not only the instrument needs to meet the requirements of this part, sample preparation and test steps The steps also need to meet the instructions in this section, especially the above-mentioned sensitive details of the test results. Equipment, test procedures, and/or sample processing Small deviations can seriously affect the repeatability, reproducibility, and test precision of test data. In general, the MVR and MFR test conditions specified in the material standards should be proposed and used to guide the test before testing. test. Materials whose rheological behavior is affected by hydrolysis, condensation or cross-linking during testing are not specified in their material standards in many cases. Test conditions for MVR and MFR values. The standards for these materials may be revised or improved later. When there is no relevant material standard or When the test conditions are not specified in the material standards, the relevant parties shall communicate the confirmation of the drying and test conditions. Note. At the time of publication, there was no evidence that using this part of the test stability material was more accurate than using GB/T 3682.1-2018. Plastic Thermoplastic Melt Mass Flow Rate (MFR) And melt volume flow rate (MVR) determination Part 2. Time-Temperature History and/or Humidity Sensitive materials test methods Warnings - The personnel in this section should be familiar with the laboratory specifications used. This section does not cover all safety issues related to use Questions, if any, are only relevant to their use. The users of this section have the responsibility to establish appropriate measures to protect personal safety and determine these regulations. The applicability of the system. Important Note. The instrument must meet the provisions of this section, need to be tested under the specified temperature and load conditions, pay attention to sample pretreatment, Strictly implement the test procedures in this section and any applicable material standards.1 ScopeThis part of GB/T 3682 specifies a thermoplastic material that is sensitive to the rheological properties of time-temperature history and/or humidity. The material's melt mass flow rate (MFR) and melt volume flow rate (MVR) methods. Note 1. Some materials are affected by the hydrolysis reaction, such as polyethylene terephthalate (PET), polybutylene terephthalate (PBT), poly naphthalene dicarboxylic acid Ethylene glycol esters (PEN), as well as other polyester polymers, polyamides, etc.; other materials are affected by cross-linking reactions such as thermoplastic elastomers (TPE) and Thermoplastic vulcanizates (TPV). This method may also be applicable to other materials. This method may not be suitable for materials whose rheological behavior is greatly affected during testing. Note 2. For those materials whose MFR and MVR have a higher coefficient of variation than that in GB/T 3682.1-2018, use the viscosity in their dilute solution (GB/T 12006.1-2009, GB/T 1632.1-2008) may be more appropriate to characterize. Note 3. Small differences in equipment, operational procedures, and/or sample processing may significantly reduce the repeatability, reproducibility, and accuracy of measurement results. Appendix B gives Under ideal conditions, using this section to test the MVR results of different materials, this shows the repeatability of this section. If the density of the material under test temperature and pressure is known, or when the cutting device is fitted, the accuracy of the measurement is at least the same as when measuring MVR, MFR can be calculated by MVR. Note 4. The required melt density should be obtained at the test temperature and load. In fact, at low pressures, the data obtained at test temperature and ambient pressure can be used. The main difference between this part and GB/T 3682.1-2018 lies in this part of the barrel temperature and the time the material has experienced at this temperature. There is a stricter tolerance. Therefore, it is necessary to strictly control the time history of materials and apply materials that are susceptible to high temperatures. Compared with the results obtained in GB/T 3682.1-2018, the use of this part can reduce the variability of the results. This section also gives methods for preparing and processing moisture-sensitive materials, which are closely related to obtaining reproducible, reproducible and accurate data. Related. The material standards generally specify the test conditions for MVR and MFR. However, for those who do not specify test conditions in the standard Materials, the test conditions should be determined by the parties concerned.2 Normative referencesThe following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article Pieces. For undated references, the latest version (including all amendments) applies to this document. GB/T 1632.1-2008 Plastics - Determination of the viscosity of dilute polymer solutions using capillary viscometers - Part 1. General (ISO 1628-1.1998,MOD) GB/T 2035-2008 Plastics terms and definitions (ISO 472.1999, IDT) ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 3682.2-2018_English be delivered?Answer: Upon your order, we will start to translate GB/T 3682.2-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 3682.2-2018_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 3682.2-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |