Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 35856-2018 English PDF

US$114.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 35856-2018: Methods of insulation resistance test and resistant high voltage test for aircraft electrical equipment
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 35856-2018114 Add to Cart 3 days Methods of insulation resistance test and resistant high voltage test for aircraft electrical equipment Valid

Similar standards

GB/T 35851   GB/T 35849   

Basic data

Standard ID: GB/T 35856-2018 (GB/T35856-2018)
Description (Translated English): Methods of insulation resistance test and resistant high voltage test for aircraft electrical equipment
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: V40
Classification of International Standard: 49.060
Word Count Estimation: 6,655
Date of Issue: 2018-02-06
Date of Implementation: 2018-02-06
Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration

GB/T 35856-2018: Methods of insulation resistance test and resistant high voltage test for aircraft electrical equipment


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods of insulation resistance test and resistant high voltage test for aircraft electrical equipment ICS 49.060 V40 National Standards of People's Republic of China Aircraft electrical equipment insulation resistance and withstand voltage test method (ISO 2678.1985, Environmental tests for aircraft equipment-Insulation Published on.2018-02-06 2018-02-06 Implementation General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China China National Standardization Administration released

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard uses the translation method equivalent to using ISO 2678. 1985 "aircraft equipment environmental test insulation resistance and high voltage test." The Chinese documents that have a consistent correspondence with the normatively cited international documents in this standard are as follows. ---HB6167 (All parts) Civil aircraft aircraft airborne equipment environmental conditions and test methods [ISO 7137 (all parts)]. This standard has made the following editorial changes. --- Modified standard name. This standard was proposed by China Aviation Industry Corporation. This standard is under the jurisdiction of the National Aircraft Standardization Technical Committee (SAC/TC435). This standard was drafted by Shaanxi Aviation Electric Co., Ltd., Northwestern Polytechnical University, Anhui Zhiyi Technology Consulting Co., Ltd., and China Airlines. Air Integrated Technology Institute, Guiyang Aviation Motor Co., Ltd. The main drafters of this standard. Zhang Xiaobin, Liu Peng, Jin Huijie, Wang Hongxia, Luo Guohua, Wang Jian, Ma Hengfei.

Introduction

0.1 This standard is part of the series of environmental tests for aircraft equipment. See other environmental tests in ISO 7137. 0.2 The safe operation of aircraft electrical equipment requires good insulation quality and withstand voltage capability. The quality and size of the insulator should be adaptable The voltage and the weather conditions affected, such as temperature, humidity, atmospheric pressure, and surface contamination. Only adopt the correct test method, Understanding and verifying the physical properties and status of the insulation enables smaller and more secure designs for electrical equipment. Insulation resistance measurement and withstand voltage test should be regarded as two different tests. Only the high insulation resistance cannot prove that the insulation has no defects. For example, When arc cracking occurs in the insulating medium, flashover voltage will be generated. 0.2.1 Voltage withstand test purpose The withstand voltage test is designed to test the insulation ability against the induction of the electric field. 0.2.2 Insulation resistance test purpose The insulation resistance measurement is to check whether the electrical equipment has enough insulation resistance value to prevent the leakage current exceeding the allowable value from passing through the insulation. In particular, under the influence of various climatic conditions such as temperature and humidity and surface contamination conditions, the electrical equipment is maintained by measuring the insulation resistance. Insulation performance. 0.2.3 Leakage Current Test Purpose Leakage current detection is suitable for devices with semiconductors. The test voltage depends on the rated voltage of the components. Aircraft electrical equipment insulation resistance and withstand voltage test method

1 Scope

This standard stipulates the insulation resistance test and withstand voltage test requirements for electrical equipment intended for installation and proposes four types of equipment. Insulation requirements. This standard applies to the insulation resistance test and withstand voltage test of electrical equipment intended for installation. This standard does not cover the installed fly Insulation test of equipment on board.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article Pieces. For undated references, the latest version (including all amendments) applies to this document. ISO 7137 Aircraft Airborne Equipment Environmental Conditions and Test Methods (Aircraft-Environmentalconditionsandtest Proceduresforairborneequipment)

3 Terms and Definitions

The following terms and definitions apply to this document. 3.1 Insulation medium meansofinsulation Gas, liquid, or solid material used for insulation. 3.2 Insulator insulation The general term for the final product form formed from insulating materials. 3.3 Insulation capacity insulationcapability The ability to withstand the appropriate level of test voltage. 3.4 Rated voltage ratedvoltage The voltage value associated with its operating characteristics specified in the marking of electrical equipment.

4 Requirements

4.1 withstand voltage 4.1.1 Test Requirements The withstand voltage test should be specified in the electrical equipment specification. When the insulation can withstand the test voltage specified in Table 1, the equipment is considered Has a sufficient insulation capacity. When it is necessary to repeat the withstand voltage test, only 80% of the test voltage specified in Table 1 shall be applied. This regulation Also applies to equipment that has been used or repaired.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 35856-2018_English be delivered?

Answer: Upon your order, we will start to translate GB/T 35856-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 35856-2018_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 35856-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.