Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 35031.301-2018 English PDF

US$479.00 ยท In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 35031.301-2018: Customer energy management system -- Part 3-1: General requirements for subsystem gateway
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 35031.301-2018479 Add to Cart 4 days Customer energy management system -- Part 3-1: General requirements for subsystem gateway Valid

Similar standards

NB/T 10613   GB/T 35967   GB/T 35727   GB/T 35031.4   GB/T 35031.302   GB/Z 35031.8   

Basic data

Standard ID: GB/T 35031.301-2018 (GB/T35031.301-2018)
Description (Translated English): Customer energy management system -- Part 3-1: General requirements for subsystem gateway
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: K00
Classification of International Standard: 29.20
Word Count Estimation: 24,229
Date of Issue: 2018-05-14
Date of Implementation: 2018-12-01
Regulation (derived from): National Standards Announcement No. 6 of 2018
Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration

GB/T 35031.301-2018: Customer energy management system -- Part 3-1: General requirements for subsystem gateway


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Client-side energy management systems Part 3-1. Subsystem interface gateways General requirements) ICS 29.20 K00 National Standards of People's Republic of China Client energy management system Part 3-1. General requirements for subsystem interface gateways Part 3-1. Generalrequirementsforsubsystemgateway Published on.2018-05-14 2018-12-01 implementation State market supervision and administration China National Standardization Administration issued

Content

Foreword III Introduction IV 1 Scope 1 2 Normative references 1 3 Terms and definitions, abbreviations 2 4 Gateway Category 4 5 Gateway function reference model and basic function configuration requirements 4 6 Gateway function requirements 6 7 Basic requirements for electrical and mechanical properties 13 8 Inspection rules 16 9 Identification, packaging, storage and transportation 17 Appendix A (informative) The location and role of the gateway in the user-side energy management system 19 Reference 20

Foreword

GB/T 35031 "Customer Energy Management System" has released the following parts. --- Part 1. Guidelines; --- Part 2. Master station function specification; --- Part 3-1. General requirements for subsystem interface gateways. This part is part 3-1 of GB/T 35031. This part is drafted in accordance with the rules given in GB/T 1.1-2009. Please note that some of the contents of this document may involve patents. The issuing organization of this document is not responsible for identifying these patents. This part was proposed by China Electrical Equipment Industry Association. This part is under the jurisdiction of the National Electrical Equipment Network Communication Interface Standardization Technical Committee (SAC/TC411). This section was drafted by. Shanghai Electric Apparatus Research Institute, Shenzhen Zhongdian Power Technology Co., Ltd., Harbin Institute of Technology, Nanrui Group company, Yantai Dongfang Weston Electric Co., Ltd., Beijing Huadian Zhongxin Technology Co., Ltd., Shanghai Shenrui Jibao Electric Co., Ltd. The main drafters of this section. Cai Zhongyong, Wu Xiaodong, Zeng Yousong, Jiang Chao, Qi Weiming, Tian Haitao, Hu Daliang, Yan Peifeng, Xie Ruobing, Yan Changjiang, Cui Ming, Wang Xuanyou, Shao Fei, Wang Wei, Wang Wei, Wei Yong, Shi Shanghui, Dong Chao, Yan Lan, Ye Qiongyu.

Introduction

The basic function of the subsystem interface gateway ("gateway") is to implement the conversion between communication protocols. With smart grid technology, energy The development of Internet technology and the continuous expansion of application requirements such as energy management and energy services, and the role of gateways in customer-side energy management systems More and more important, requiring more and more functions, so some gateway products with energy management functions have emerged, such as data collection. The gateway integrates the functions of acquisition, processing and storage; the energy management gateway has the function of monitoring, calculating and judging the energy data; The resource gateway uses the transmitted and monitored data information as a network resource to support the "Internet" energy in the form of data publish/subscribe. management. The gateway is the key equipment of the customer-side energy management system. It will be the internal distribution system, photovoltaic system, wind power system and energy storage system. Various subsystems such as system, charging pile system, smart home system, intelligent lighting system and air conditioning system are connected to the customer energy management system. The definitions and requirements for gateways in this section are based on the following gateway functional vision. 1) Data conversion. the gateway converts the subsystem local mode data into the global mode data of the client management system, so that different types, Energy data from subsystems of different manufacturers can be integrated with each other; 2) Plug and Play. Introduce the data publish/subscribe mechanism so that the gateway can connect the subsystem to the client network, and the master system can scan Discover the existence of the subsystem, and select whether the subsystem is included in the user-side energy management system management from the system operation interface. The monitoring points that need to be managed in the stator system, the parameters to be monitored at each monitoring point, and the frequency of data acquisition, etc., the system can Dynamically generate subsystem files, monitoring point files, and automatically run according to selected monitoring data and acquisition frequency, no need for professionals New configuration system application software; 3) Energy management. for different applications, the gateway is given optional local energy management functions such as classification, monitoring and warning. Ability to apply to various energy management needs in an economically sound manner; 4) Access authorization management. Through access rights management, the gateway can connect subsystems to the Internet, allowing subsystems and external third parties The energy management platform is interconnected. This part establishes the functional reference model of the gateway from the vision of the gateway function. Based on this model, various functional requirements are specified. This part starts from the role of maximizing the gateway and puts forward the requirements for the energy management function of the gateway. Actual application by the main station The same energy management functions are now easier and more practical. This part of the energy management function of the gateway gives meter reading billing, monitoring and early warning, classification, maximum demand and data statistics, etc. Independent energy management functions, there must be more functions and forms in practical applications. This part is about the general requirements of the subsystem interface gateway, the data configuration method of the subsystem interface gateway, and the connection of various subsystems. Specific technical specifications will be specified in subsequent research and development standards. Client energy management system Part 3-1. General requirements for subsystem interface gateways

1 Scope

This part of GB/T 35031 establishes the functional reference model of the subsystem interface gateway and specifies the basic functional configuration requirements. Functional requirements for CEMS subsystem communication, communication with CEMS master station, local management, data management, and energy management are proposed. On this basis, the general requirements of six aspects such as electrical, mechanical, inspection, marking, packaging, storage and transportation are given. Note. This section is limited to discussing the embedded interface gateway. It is not excluded that the user can load the CEMS subsystem by loading the data conversion software module in the CEMS subsystem. Enter the CEMS master station network to implement the subsystem interface gateway function. This section applies to the development, production, inspection and use of subsystem interface gateway products.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 191-2008 packaging storage and transportation icon GB/T 2423.10-2008 Environmental testing for electric and electronic products - Part 2. Test method test Fc. Vibration (sinusoidal) GB/T 4208-2017 enclosure protection grade (IP code) GB/T 5169.11-2006 Electrical and electronic products - Fire hazard testing - Part 11. Glowing wire/hot wire basic test method Glowing wire flammability test method GB/T 9254-2008 Radio disturbance limits and methods of measurement for information technology equipment GB/T 17626.2-2006 Electromagnetic compatibility test and measurement technology Electrostatic discharge immunity test GB/T 17626.3-2016 Electromagnetic compatibility test and measurement technology RF electromagnetic field radiation immunity test GB/T 17626.4-2008 Electromagnetic compatibility test and measurement technology Electrical fast transient burst immunity test GB/T 17626.5-2008 Electromagnetic compatibility test and measurement technology Surge (impact) immunity test GB/T 17626.6-2008 Electromagnetic compatibility test and measurement technology Conducted disturbance immunity of RF field induction GB/T 17626.8-2006 Electromagnetic compatibility test and measurement technology Power frequency magnetic field immunity test GB/T 20138-2006 Degree of protection of external mechanical collisions of electrical equipment enclosures (IK code) GB /Z 32500-2016 General requirements for data interface of smart grid client system GB /Z 32501-2016 General requirements for smart grid customer communication systems GB/T 35031.1-2018 User-end energy management systems - Part 1. Guide GB/T 35031.2-2018 User-end energy management systems - Part 2 IEEE 802.3-2015 Information technology telecommunications and information exchange between systems - Local area network and metropolitan area network specification requirements Part 3 Points. Carrier Detection Multiple Access with Collision Detection Access Method (CSMA/CD) and Physical Layer Specification [Informationtechnology- Telecommunicationsandinformationexchangebetweensystems-Localandmetropolitanareanet- works-Specificrequirements-Part 3. Carriersensemultipleaccesswithcolisiondetection(CSMA/ CD) accessmethodandphysicallayer]
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 35031.301-2018_English be delivered?

Answer: Upon your order, we will start to translate GB/T 35031.301-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 35031.301-2018_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 35031.301-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.