Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GBZ35031.8-2021 English PDF

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/Z 35031.8-2021RFQ ASK 3 days Customer energy management system - Part 8: Use cases Valid

Similar standards

NB/T 10613   GB/T 35967   GB/T 35727   GB/T 35031.4   GB/T 35031.7   GB/T 35031.6   

Basic data

Standard ID: GB/Z 35031.8-2021 (GB/Z35031.8-2021)
Description (Translated English): Customer energy management system - Part 8: Use cases
Sector / Industry: National Standard
Classification of Chinese Standard: K00
Word Count Estimation: 202,223
Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration

GBZ35031.8-2021: Customer energy management system - Part 8: Use cases

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
GB /Z 35031.8-2021 Customer energy management system - Part 8.Use cases ICS 29.020 K00 National Standardization Guiding Technical Documents of the People's Republic of China User-side Energy Management System Part 8.Use Cases Released on 2021-03-09 2021-10-01 implementation State Administration of Market Supervision and Administration Issued by the National Standardization Management Committee

Table of contents

Foreword Ⅲ 1 Scope 1 2 Normative references 1 3 Terms, definitions and abbreviations 1 3.1 Terms and definitions 1 3.2 Abbreviations 2 4 Major CEMS Participants 2 4.1 Diagram of CEMS Participants 2 4.2 CEMS participant description 2 5 Client Energy Service Project (CEMS-SP) 4 6 Use case code and scenario code 5 6.1 Use Case Code (Use Case ID) 5 6.2 Scene code (scene ID) 6 7 CEMS use case layout 6 7.1 CEMS use case classification 6 7.2 CEMS use case layout 6 8 CEMS use case template 7 9 CEMS use case collection 7 Appendix A (normative appendix) CEMS use case template 8 A.1 CEMS use case template 8 A.2 CEMS use case template meaning description 10 Appendix B (informative appendix) CEMS use case collection 12 B.1 List of CEMS Use Cases and Scenarios 12 B.2 Use Case Set 14 Figure 1 Schematic diagram of CEMS participants 2 Figure 2 CEMS use case layout and the relationship between use cases Figure 7 Table 1 List of main CEMS participants (sorted in alphabetical order of participant names) 3 Table 2 Customer-side energy service project (CEMS-SP) description 4 Table 3 Scope and objectives of various use cases 6 Table A.1 Use case identification template 8 Table A.2 Scope and target template 8 Table A.3 Use case description template 8 Table A.4 Use Case Condition Template 8 Table A.5 Scenario summary template 9 Table A.6 Scenario Step Template 9 Table A.7 Participant Template 9 Table A.8 Interactive Information Template 9 Table A.9 Version Modification Record Template 10 Table B.1 CEMS use cases and scenarios list 12

Foreword

GB/T 35031 "User-side Energy Management System" has released the following parts. ---Part 1.Guidelines; ---Part 2.Functional specifications of the master station; ---Part 3-1.General requirements for subsystem interface gateways; ---Part 6.Management indicator system; ---Part 7.Function classification and system classification; ---Part 8.Use cases. This part is Part 8 of GB/T 35031. This section was drafted in accordance with the rules given in GB/T 1.1-2009. Please note that some of the contents of this document may involve patents. The issuing agency of this document is not responsible for identifying these patents. This part was proposed by the China Electrical Equipment Industry Association. This part is under the jurisdiction of the National Electrical Equipment Network Communication Interface Standardization Technical Committee (SAC/TC411). The main drafting units of this section. Shanghai Electrical Apparatus Research Institute, Shanghai Ubiku Electric Co., Ltd., Tongji University, Yantai Oriental Weston Electric Co., Ltd., Beijing Huadian Zhongxin Technology Co., Ltd., Harbin Institute of Technology, Shanghai Tengtian Energy-saving Technology Co., Ltd., Changshu Kai Guan Manufacturing Co., Ltd. (formerly Changshu Switchgear Factory), China Electric Power Research Institute Co., Ltd., Shanghai Weilai Automobile Co., Ltd., Shanghai Electric Power University School, Northwestern Polytechnical University, Nanjing Daquan Electric Research Institute Co., Ltd., Xiamen ABB Low Voltage Electrical Equipment Co., Ltd., Shanghai Liangxin Electric Co., Ltd. Co., Ltd. The main drafters of this section. Cai Zhongyong, Xi Peifeng, Hu Daliang, Lu Jianfeng, Ju Changjiang, Tian Haitao, Tong Weiming, Lu Lin, Chen Ping, Zhang Hao, Liu Xiaochun, Tang Jun, Wang Yujing, Liu Jun, Li Xiaolu, Pan Mingming, Chen Dingjian, Cui Ming, Peng Daogang, Wang Jingyu, Zou Xiaoming, Xu Zeliang, Chen Li, Liu Liang, Wei Yong, Liu Tao, Xie Jianbo, Xie Ruobing, He Ke, Wang Luyue. User-side Energy Management System Part 8.Use Cases

1 Scope

This part of GB/T 35031 defines the main participants, energy service items, use case codes and use cases of the user-side energy management system The scenario code, use case layout and use case template include the use cases of the client energy management system (CEMS) compiled accordingly. This part is compiled for the understanding and design of the user-side energy management system, and is suitable for analyzing the actual application field of the user-side energy management system. Participants in the scene, the connection between participants and participants, information interaction, and the sequence of information interaction.

2 Normative references

The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article Pieces. For undated reference documents, the latest version (including all amendments) is applicable to this document. GB /Z 32500-2016 General requirements for data interface of smart grid user-end systems GB /Z 32501-2016 General requirements for smart grid user-side communication systems GB/T 35031.1-2018 User-side energy management system Part 1.Guidelines GB/T 35031.2-2018 User-side energy management system Part 2.Master station function specification GB/T 35031.301-2018 User-side Energy Management System Part 3-1.General Requirements for Subsystem Interface Gateway GB/T 35031.6-2019 User-side Energy Management System Part 6.Management Index System GB/T 39260.2-2020 Use Case Method Part 2.Definition of Use Case Template, Participant List and Requirements List 3 Terms, definitions and abbreviations 3.1 Terms and definitions The following terms and definitions defined in GB/T 39260.2-2020 and GB/T 35031.6-2019 apply to this document. in order to For ease of use, some terms and definitions in GB/T 39260.2-2020 and GB/T 35031.6-2019 are repeatedly listed below. 3.1.1 Usecase Description of a series of activities completed by the system, the significant results that these activities can produce are usually one or more participation in the system Parties or other stakeholders have value. [GB/T 39260.2-2020, definition 3.1] 3.1.2 Usecasetemplate A table for structured description of use cases in predefined fields. [GB/T 39260.2-2020, definition 3.4] 3.1.3 Actor The entity of communication and interaction. Note. Rewrite GB/T 39260.2-2020, definition 3.2.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GBZ35031.8-2021_English be delivered?

Answer: Upon your order, we will start to translate GBZ35031.8-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GBZ35031.8-2021_English with my colleagues?

Answer: Yes. The purchased PDF of GBZ35031.8-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.