Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 3389-2008 English PDF

US$929.00 · In stock
Delivery: <= 7 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 3389-2008: Test methods for the properties of piezoelectric ceramics -- Test for the performance parameter
Status: Valid

GB/T 3389: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 3389-2008929 Add to Cart 7 days Test methods for the properties of piezoelectric ceramics -- Test for the performance parameter Valid
GB/T 3389.1-1996909 Add to Cart 5 days Vocabulary for ferroelectric and piezoelectric ceramics  
GB 3389.1-1982919 Add to Cart 6 days Test methods for the properties of piezoelectric ceramics commonly used terms Obsolete

Similar standards

GB/T 4184   GB/T 5838.43   GB/T 5593   GB/T 4185   GB/T 4181   

Basic data

Standard ID: GB/T 3389-2008 (GB/T3389-2008)
Description (Translated English): Test methods for the properties of piezoelectric ceramics -- Test for the performance parameter
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: L90
Classification of International Standard: 31-030
Word Count Estimation: 42,419
Date of Issue: 2008-08-04
Date of Implementation: 2009-02-01
Older Standard (superseded by this standard): GB/T 3389.2-1999; GB/T 3389.3-2001; GB/T 3389.4-1982; GB/T 3389.5-1995; GB/T 3389.6-1997; GB/T 3389.7-1986; GB/T 3389.8-1986
Quoted Standard: GB/T 2413; GB/T 2414.1; GB/T 3389.1; CB/T 1218-1993
Regulation (derived from): Announcement of Newly Approved National Standards No. 12 of 2008 (No. 125 overall)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the piezoelectric ceramic material properties of the test conditions, test methods and test methods vibration mode. This standard applies to the Curie temperature piezoelectric ceramics, piezoelectric strain constant (static), high field dielectric properties, pyroelectric coefficient of parametric tests, the longitudinal length of piezoelectric ceramic materials telescopic cylinder, telescopic and wafer thickness rectangular slice thickness shear vibration mode parametric test.

GB/T 3389-2008: Test methods for the properties of piezoelectric ceramics -- Test for the performance parameter


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Test methods for the properties of piezoelectric ceramics. Test for the performance parameter ICS 31-030 L90 National Standards of People's Republic of China Replacing GB/T 3389.2-1999, GB/T 3389.3-2001, GB/T 3389.4-1982, GB/T 3389.5-1995, GB/T 3389.6-1997, GB/T 3389.7-1986, GB/T 3389.8-1986 Properties of piezoelectric ceramics test methods Test performance parameters Posted 2008-08-04 2009-02-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms, definitions and symbols 1 4 1 Test Conditions 4.1 Test atmospheric conditions 1 4.2 Test atmospheric conditions arbitration 1 5 Performance Test 1 5.1 Curie temperature 1 5.2 longitudinal piezoelectric strain constant (static) 2 5.3 High Field Dielectric Properties 4 5.4 pyroelectric coefficient 6 5.5 cylinder longitudinal length extension vibration mode 7 5.6 Thickness extension vibration mode 10 5.7 rectangular sheet thickness shear vibration mode 12 --- GB/T 3389.4-1982; --- GB/T 3389.5-1982, GB/T 3389.5-1995; --- GB/T 3389.6-1982, GB/T 3389.6-1997; --- GB/T 3389.7-1986; --- GB/T 3389.8-1986. Properties of piezoelectric ceramics test methods Test performance parameters

1 Scope

This standard specifies the test methods of piezoelectric ceramics test conditions, test methods and vibration mode. This standard applies to the Curie temperature of the piezoelectric ceramic material, the Senate piezoelectric strain constant (static), the strong field dielectric properties, pyroelectric coefficient The number of tests, the piezoelectric ceramic material cylinder longitudinal length of the stretch, stretch and rectangular wafer thickness thickness shear vibration mode parameter testing.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 2413 piezoelectric ceramic material bulk density measurement method GB/T 2414.1 Test methods for properties of piezoelectric ceramics discs radially stretching vibration mode GB/T 3389.1 ferroelectric ceramics vocabulary CB/T 1218-1993 hydroacoustic common piezoelectric ceramic element 3 Terms, definitions and symbols GB/T terms, definitions and symbols established 3389.1 apply to this standard.

4 Test Conditions

4.1 Test atmospheric conditions Test atmospheric conditions are as follows. a) Temperature. 15 ℃ ~ 35 ℃; b) Relative humidity. 25% to 75%; c) Atmospheric pressure. 86kPa ~ 106kPa. 4.2 Arbitration test atmospheric conditions Arbitration test atmospheric conditions are as follows. a) temperature. 25 ℃ ± 2 ℃; b) Relative humidity. 45% to 55%; c) Atmospheric pressure. 86kPa ~ 106kPa.

5 Performance Testing

5.1 Curie temperature 5.1.1 Test principle When the temperature is higher than the Curie temperature (TC), the piezoelectric ceramics in the paraelectric phase, spontaneous polarization and piezoelectric properties also vanish. The Curie temperature Degrees, many of the physical properties of piezoelectric ceramic material, such as permittivity, heat capacity, coefficient of linear expansion are mutated, so long as this measurement Point mutations can determine the temperature corresponding to the Curie temperature of the piezoelectric ceramic material. This standard uses a test sample to determine the permittivity of the piezoelectric point mutation Curie temperature of the ceramic material, and recommended impedance analyzer to measure the mutation point.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 3389-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 3389-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 7 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 3389-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 3389-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 3389-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 3389-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.