GB/T 33682-2025 English PDFUS$199.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 33682-2025: General microoganism identification method with matrix-assisted laser desorption/ionization time of flight mass spectrometry Status: Valid GB/T 33682: Historical versions
Basic dataStandard ID: GB/T 33682-2025 (GB/T33682-2025)Description (Translated English): General microoganism identification method with matrix-assisted laser desorption/ionization time of flight mass spectrometry Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: A40 Classification of International Standard: 07.080 Word Count Estimation: 9,935 Date of Issue: 2025-05-30 Date of Implementation: 2025-09-01 Older Standard (superseded by this standard): GB/T 33682-2017 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB/T 33682-2025: General microoganism identification method with matrix-assisted laser desorption/ionization time of flight mass spectrometry---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. ICS 07.080 CCSA40 National Standard of the People's Republic of China Replaces GB/T 33682-2017 Matrix-assisted laser desorption ionization time-of-flight mass spectrometry General principles for methods of identification of microorganisms Released on 2025-05-30 2025-09-01 Implementation State Administration for Market Regulation The National Standardization Administration issued ForewordThis document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1.Structure and drafting rules for standardization documents" Drafting. This document replaces GB/T 33682-2017 "General rules for identification of microorganisms by matrix-assisted laser desorption ionization time-of-flight mass spectrometry" and Compared with GB/T 33682-2017, in addition to structural adjustments and editorial changes, the main technical changes are as follows. --- Added requirements for pre-treatment methods for different strains (see 8.2); --- Added instrument setting condition requirements (see 8.4.1); --- Added "quality control" requirements (see 8.6); --- Changed the interpretation criteria of “result interpretation” (see 8.8, 8.7 of the.2017 edition); --- Changed the reporting requirements for “Results Report” (Chapter 9, Chapter 9 of the.2017 edition). Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents. This document was proposed and coordinated by the National Technical Committee for Biochemical Testing Standardization (SAC/TC387). This document was drafted by. Hebei Provincial Food Inspection Institute, China Testing Technology Research Institute, Heilongjiang Provincial Intellectual Property Protection Center, Tsinghua University University, Guangzhou Huaxin Testing Technology Co., Ltd., Suzhou Shipu Testing Technology Co., Ltd., Henan University, Beijing Institute of Food Science, Nanjing University of Finance and Economics, Hebei Medical University, Beijing Technology and Business University, Zhejiang University of Technology, China Institute of Inspection and Quarantine, Lanzhou Baiyuan Gene Technology Ltd. The main drafters of this document are. Zhang Yan, Zhou Wei, Wang Yi, Zhou Lihua, Peng Liping, Li Yongbo, Kang Wenyi, Sun Yong, Lv Pin, Wendi, Fan Sufang, Tang Xiaozhi, Feng Xiao, Zhang Yalun, Wang Yanbo, Zhou Xuxia, Zhang Rui, Che Tuanjie, Chen Chen, Liao Huayong, Dai Dan, Wang Hui, Liu Shuai, Ren Xiaoyan, Niu Xiangtao, Zou Yan and Zheng Xiaoling. The previous versions of this document and the documents it replaces are as follows. ---First published in.2017 as GB/T 33682-2017; ---This is the first revision. Matrix-assisted laser desorption ionization time-of-flight mass spectrometry General principles for methods of identification of microorganisms1 ScopeThis document specifies the general method for identification of microorganisms by matrix-assisted laser desorption ionization time-of-flight mass spectrometry. This document applies to the matrix-assisted laser desorption ionization time-of-flight mass spectrometry identification of microbial species.2 Normative referencesThe contents of the following documents constitute essential clauses of this document through normative references in this document. For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to This document. GB/T 6682 Specifications and test methods for water used in analytical laboratories GB 19489 General requirements for laboratory biosafety3 Terms and definitionsThe following terms and definitions apply to this document. 3.1 The isolated and purified single colony is directly applied to the target plate, and after drying, the matrix is added and mixed. The microbial soluble protein and the matrix form After forming co-crystals, mass spectrometry fingerprints of protein molecules with different mass-to-charge ratios were obtained through a vacuum time-of-flight tube.4 AbbreviationsThe following abbreviations apply to this document. BTS. Bacteria Detection Standard Sample. MALDI-TOFMS. matrix-assisted laser desorption ionization time-of-flight mass spectrometry. MALDI-TOF-TOFMS. matrix-assisted laser desorption ionization time-of-flight tandem mass spectrometry. MSP. main spectrum plot.5 PrincipleCommon microorganisms are composed of special proteins that are different from other species, and therefore have unique protein fingerprints, which are determined by species. It is determined by the genetic characteristics and is less affected by external environmental conditions. Samples (from clinical samples such as sputum, blood, body fluids, swabs, and food, cosmetics, medicines, and the environment, etc.) are properly processed and cultured in solid After culturing and isolating a single colony on the matrix, the sample was directly spotted onto the target plate and placed into the matrix-assisted laser desorption ionization time-of-flight mass spectrometer. Ionization is separated according to the mass/charge (m/z) ratio, and the collected data is compared with the microbial fingerprint library for identification. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 33682-2025_English be delivered?Answer: Upon your order, we will start to translate GB/T 33682-2025_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 33682-2025_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 33682-2025_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 33682-2025?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 33682-2025 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |