GB/T 32593-2016 English PDFUS$939.00 · In stock
Delivery: <= 7 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 32593-2016: Railway applications -- Fixed installations -- Electronic power converters for substations Status: Valid
Basic dataStandard ID: GB/T 32593-2016 (GB/T32593-2016)Description (Translated English): Railway applications -- Fixed installations -- Electronic power converters for substations Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: S81 Classification of International Standard: 29.280 Word Count Estimation: 47,445 Date of Issue: 2016-04-25 Date of Implementation: 2016-11-01 Quoted Standard: GB/T 1402; GB/T 2900.33; GB/T 2900.36; GB/T 3859.1; GB/T 3859.2-2013; GB/T 3859.3; GB/T 3859.4; GB 4208-2008; GB/T 17950; GB/T 18039.4; GB/T 24338.1; GB/T 24338.2; GB/T 24338.3; GB/T 24338.4; GB/T 24338.5; GB/T 24338.6; GB/T 25890.7; GB/T 32350.1-2015; IEC 61000-2-12; IEC 6 Adopted Standard: IEC 62590-2010, MOD Regulation (derived from): National Standard Announcement No Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the use of controllable or uncontrolled power valve, traction power to provide the technical requirements of the ground power supply device. This standard applies to devices subject to current, voltage, or light, and assumes that non-bistable devices operate in switch mode. This standard applies to terrestrial installations for railways and guided large-volume systems (eg, trams, light rail systems, elevated railways and subways, mountain railways, trolleybuses). This standard applies to diode rectifiers, controllable rectifiers, inverters and frequency converters. This standard does not apply to cranes, transshipment platforms in rail systems and similar transport equipment, suspended vehicles and cable railways. GB/T 32593-2016: Railway applications -- Fixed installations -- Electronic power converters for substations---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Railway applications - Fixed installations - Electronic power converters for substations ICS 29.280 S81 National Standards of People's Republic of China Rail transit ground equipment Power electronic converter for substation (IEC 62590..2010, MOD) 2016-04-25 released 2016-11-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China China National Standardization Management Committee released Directory Preface III 1 Scope 1 2 normative reference document 1 3 Terms and definitions 2 3.1 Semiconductor devices and components 2 3.2 arm and connection 2 3.3 Working quadrant and controllability of the converter arm 4 3.4 commutation, extinguishing and commutation circuit 5 3.5 commutation characteristics 5 3.6 Rating 8 3.7 Load capacity 9 3.8 Specific voltage, current and factor 9 3.9 Definitions of equivalent junction temperature 10 3.10 cooling 11 3.11 Electromagnetic compatibility and harmonic distortion 11 4 Application of semiconductor power equipment and valve devices 12 Classification of traction powered power converters and valve devices 4.2 Basic symbols 12 4.3 Basic calculation factors for grid commutation converter 5 working conditions 14 5.1 Symbols for cooling mode 14 5.2 Environmental conditions 16 5.3 Electrical working conditions 17 6 converter and system6.1 Electrical connection 19 6.2 Calculate factor 20 6.3 Loss and efficiency 20 6.4 Power factor 20 6.5 DC voltage harmonic components 21 6.6 Electromagnetic compatibility (EMC) 21 6.7 converter rating 21 6.8 Mechanical properties 23 6.9 logo 24 7 Test 24 7.1 General 24 7.2 Test methods 25 Appendix A (informative) Information required Appendix B (informative) Determine the withstand current capability by equivalent junction temperature calculation Reference 39 Index 40ForewordThis standard is drafted in accordance with the rules given in GB/T 1.1-2009. This standard uses the re-drafting method to amend the use of IEC 62590..2010 "rail transit equipment for substation power electronics Flow device ". There is a technical difference between this standard and IEC 62590..2010, and these differences involve the use of vertical single-line (︱) Line markings. The technical differences between this standard and IEC 62590..2010 are. --- on the normative reference documents, this standard has made a technical differences in the adjustment to meet China's technical conditions, adjust the situation The situation is reflected in Chapter 2, "Normative references", as follows. Replace GB 60850..2007 with GB/T 1402; Replace IEC 60050-551..1998 with GB/T 2900.33; Replace GB 60000-811..1991 with GB/T 2900.36; ● replace GB 60146-1-1 with GB/T 3859.1; Replace GB 608-1-1..2011 with GB/T 3859.2-2013; ● replace GB 60146-1-3 with GB/T 3859.3; ● replace GB 608..2000 with GB/T 3859.4; Replace GB 607-6..1992 with GB/T 17950; ● Replace the IEC 62236 (all parts) with GB/T 24338 rail traffic electromagnetic compatibility (all parts), two standards The degree of consistency between the parts is as follows. Railways - Electromagnetic compatibility - Part 1. General principles (IEC 62236-1..2003, IDT); GB/T 24338.2-2011 Electromagnetic compatibility for rail transit Part 2. Launch of the entire track system to the outside world (IEC 62236-2..2003, IDT); Railways - Electromagnetic compatibility - Part 3-1. Locomotives and rolling stock - Trains and vehicles - GB/T 24338.3-2009. (IEC 62236-3-1..2003, IDT); Railways - Electromagnetic compatibility - Part 3-2. Locomotives and rolling stock equipment GB/T 24338.4-2009 (IEC 62236-3-2..2003, MOD); Electromagnetic compatibility for rail transit - Part 4. Launch and resistance of signaling and communication equipment GB/T 24338.5-2009 Disturbance (IEC 62236-4..2003, IDT); Railways - Electromagnetic compatibility - Part 5. Launch of ground power installations and equipment GB/T 24338.6-2009 And Immunity (IEC 62236-5..2003, IDT). Replace GB 618-2-7..2006 with GB/T 25890.7; Replace IEC 62497-1..2010 with GB/T 32350.1-2015. - modified normative reference document IEC 60271, replaced by IEC 62498, since IEC 62498 is a ring dedicated to rail transit Conditions of environmental conditions; --- added the term definition "3.3.11 inverter", a clear distinction between the converter and inverter; --- modified 5.2.2.2 storage temperature of "-40 ℃ ~ 55 ℃" and increase the ambient temperature "-25 ℃ ~ 40 ℃", and track Traffic and electrical equipment commonly used temperature requirements uniform; --- modified in Table 4 on the current capacity of the converter test mode, and GB/T 3859.1 converter current capability test Unite; - In 7.2.1.1, "Insulation resistance measurement is not required as a required test item" at the time of factory inspection, because the insulation resistance measurement The insulation resistance of each product can be checked for the inspection of the factory. This standard has made the following editorial changes. --- deleted the original introduction; --- "the equipment in this standard is specifically referred to as the converter" at the end of the original Chapter 1, and the other parts refer to the "device" of the converter As "converter" to avoid misunderstanding; --- removed in Chapter 2 in IEC 62236-5..2008, since all parts of GB/T 24338 have been referenced as a whole; - modify 4.3.1 in paragraph 1 of paragraph 1, "calculated by the following formula" as "the following formula (p = q × s)", supplementary description q and s with the formula p Relationship in order to understand; --- modified the full text of many paragraphs, the original sub-clause under the single sentence paragraph merger, to reduce the paragraph structure; --- modify the 7.2.1.1 paragraph, to increase the number of untitled, to solve too many paragraphs, to facilitate the reference; - Fixed footnote b in Table 6 "See 3.3.1" and should be "see 6.3.1"; --- Amend the converter type in Appendix A "see 4.3.1" and shall be "see 4.1.1"; --- modify the appendix C for the index to meet the Chinese habit. This standard is proposed by the National Railway Administration. This standard is nationalized by the National Technical Committee for Traction Electrical Equipment and Systems (SAC/TC278). The main drafting unit of this standard. Zhuzhou converter technology National Engineering Research Center Co., Ltd. This standard participates in the drafting unit. Yongji new speed motor electrical limited liability company, CSR Nanjing Puzhen Vehicle Co., Ltd., CSR Zhuzhou Electric Locomotive Co., Ltd., China Railway Fourth Survey and Design Institute Group Co., Ltd. The main drafters of this standard. Luo Renjun, Tan Shengwu. This standard participates in the drafters. Chen Xue, Chen Guanghu, Song Chunlong, Yan Gang, Qi Guangfeng. Rail transit ground equipment Power electronic converter for substation1 ScopeThis standard specifies the technical requirements for the use of controlled or non-controllable power valves to provide ground power supply for traction power. This standard applies to devices where the device is controlled by current, voltage, or light, and assumes that the non-bistable device is in switch mode. This standard applies to railways and guided large traffic systems (eg trams, light rail systems, elevated railways and subways, mountain areas Rail, trolleybus) ground equipment. This standard applies to diode rectifiers, controllable rectifiers, inverters and frequency converters. This standard does not apply to cranes, rail transit platforms and similar transport equipment, suspended vehicles and cable railways.2 normative reference documentsThe following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. GB/T 1402 Rail Transit Traction Power Supply System Voltage (IEC 60850..2007, MOD) GB/T 2900.33 Electrical terminology Power electronics technology (IEC 60050-551..1998, IDT) GB/T 2900.36 Electrical terminology Electric traction (IEC 60050 (811)..1991, MOD) GB/T 3859.1 General Requirements for Semiconductor Converters and Grid Replacement Converters - Part 1-1. Basic Requirements Specifications (IEC 60146-1-1..1991, MOD) GB/T 3859.2-2013 General Requirements for Semiconductor Converters and Grid Replacement Converters - Part 1-2. Application Guidelines (IEC 60146-1-2..2011, MOD) GB/T 3859.3 General requirements for semiconductor converters and grid commutators - Part 1-3. Transformers and reactors (IEC 60146-1-3..1991, MOD) GB/T 3859.4 Semiconductor converters include semiconductor direct commutators for direct DC converters (IEC 60146-2..1999, IDT) GB 4208-2008 enclosure protection class (IP code) (IEC 60529..2001, IDT) GB/T 17950 Semiconductor converters - Part 6. Guidelines for the use of fuses to protect semiconductor converters against overcurrent (IEC 60146-6..1992, IDT) GB/T 18039.4 Electromagnetic compatibility environment Factory low frequency transmission disturbance compatibility level (GB/T 18039.4-2003, IEC 61000-2-4..1994, IDT) GB/T 24338 (all parts) Rail traffic Electromagnetic compatibility [IEC 62236 (alpart)] GB/T 25890.7 Metro equipment - DC switchgear - Part 7-1. DC traction power supply system - Special measurement, Control and Protection Device Application Guide (IEC 61992-7-1..2006, IDT) GB/T 32350.1-2015 Rail traffic insulation fits Part 1. Basic requirements Electrical and electronic equipment, electrical clearance And creepage distance (IEC 62497-1..2010, MOD) Electromagnetic compatibility (EMC) - Part 2-12. Ambient in low - frequency conducted disturbances in a public medium - voltage power supply system IEC 61000-2-12 And the level of compatibility of the signal transmission (Electromagneticcompatibility (EMC) -Part 2-12. Environment-Compati- bilitylevelsforlow-frequencyconducteddisturbancesandsignalinginpublicmedium-voltagepower ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 32593-2016_English be delivered?Answer: Upon your order, we will start to translate GB/T 32593-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 7 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 32593-2016_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 32593-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |