Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 31540.4-2015 English PDF

US$549.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 31540.4-2015: Fire safety engineering guide -- Part 4: Detection, activation and suppression
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 31540.4-2015549 Add to Cart 5 days Fire safety engineering guide -- Part 4: Detection, activation and suppression Valid

Similar standards

GB 23864   GB 32157   GB 25204   GB/T 31540.5   GB/T 31540.2   GB/T 31540.3   

Basic data

Standard ID: GB/T 31540.4-2015 (GB/T31540.4-2015)
Description (Translated English): Fire safety engineering guide -- Part 4: Detection, activation and suppression
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: C84
Classification of International Standard: 13.220.01
Word Count Estimation: 26,241
Date of Issue: 2015-05-15
Date of Implementation: 2015-08-01
Quoted Standard: GB/T 5907.1; GB/T 5907.2; GB/T 5907.3; GB/T 5907.4; GB/T 5907.5; GB/T 31540.1; GB 50084
Adopted Standard: ISO/TR 13387-7-1999, MOD
Regulation (derived from): National Standard Announcement 2015 No. 15
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This Standard specifies the method for building automatic fire engineering analysis facilities for automatic fire alarm detection time computing systems and automatic fire extinguishing system start-up time, as well as automatic fire extinguishing system performance assessment. This section does not consider the impact of human intervention on the detection, start-up and fire-fighting.

GB/T 31540.4-2015: Fire safety engineering guide -- Part 4: Detection, activation and suppression

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Fire safety engineering guide - Part 4. Detection, activation and suppression ICS 13.220.01 C84 National Standards of People's Republic of China Fire Safety Engineering Guidelines Part 4. detection, and fire started Part 4. Detection, activationandsuppression (ISO /T R13387-7.1999, Firesafetyengineering-Detection, activationandsuppression, MOD) Issued on. 2015-05-15 2015-08-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ Introduction Ⅳ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 Symbols and abbreviations 2 Use subsystem 5 4 Note 2 5.1 General 2 5.2 Information Flow 4 Assessment Subsystem 4 6 4 Content Detection time 6.1 4 6.2 Start Time 7 6.3 fire-extinguishing system performance 11 7 Project Evaluation 15 7.1 General provisions 15 7.2 Empirical Formula 15 7.3 computer model 15 7.4 Test 16 Appendix A (informative) of this section and the ISO /T R13387-7. Article 1999 of Chapter 17 case control number Annex B (informative) of this section and the ISO /T R13387-7. technical differences between 1999 and Its Causes 19 Annex C (informative) Water spray extinguishing mechanism 20 Annex D (informative) fixed temperature detector response time is calculated as 21

Foreword

GB/T 31540 "Fire Safety Engineering Guide" is divided into the following sections. --- Part 1. Performance-based design application; --- Part 2. fire, smoke generation and development; --- Part 3. Structural Response and indoor fires spread outside; --- Part 4. detection, and fire started; This section GB/T Part of 431,540. This section drafted in accordance with GB/T 1.1-2009 given rules. This section uses redrafted law revision using ISO /T R13387-7.1999 "Fire Safety Engineering Guidelines detection, start-up and fire." This part of ISO /T R13387-7. in 1999, compared with more structural adjustment, listed in Appendix A of this section and ISO /T R13387-7. reg number control list 1999. This part of ISO /T R13387-7.1999 technical differences exist compared to the terms of these differences has been involved through its outer margin Vertical single line blank position (|) have been marked, in Appendix B gives the corresponding list of technical differences and their causes. For ease of use and compliance with the requirements of the relevant standards prepared, this section also made the following editorial changes. --- Deleted international standards foreword, preface redrafted; --- Modify the introduction of international standards, as a part of this introduction; --- International standard "this International Standard" be replaced by "this section"; --- The International Standard some punctuation modified to comply with the Chinese habit of punctuation; --- Delete references; --- Added Appendix A (informative), gives this part of the international standard reg number control the situation; --- Added Appendix B (informative), gives a technical difference between this part and the international standards and reasons. This section presents the People's Republic of China Ministry of Public Security. This part of the National Standardization Technical Committee on Fire Building Fire Safety Engineering at the Technical Committee (SAC/TC113/SC13) Centralized. This section is responsible for drafting unit. Ministry of Public Security of Sichuan Fire Research Institute. Participated in the drafting of this section. Shenyang Fire Research Institute Ministry of Public Security, Beijing Lida Group Limited. The main drafters of this section. Wang Jiong Deng Ling Feng Xiaojun, Mei Zhibin, Zhang Xian, the bear Yun, Tu Yan Lin, Lu Guojian, Liu Junjun, Wu Ping, Wang Liping, Zhang Xiaoming.

Introduction

Use and management of buildings through various detection device discovery and control of fire, so that the buildings meet safety standards, and reducing Fire damage. This part of GB/T 31540.1 specified in a variety of active fire fighting facilities Subsystem 4 building set in the analysis and evaluation. Subsystem 4 can be used to calculate various fire detection detection time, the operating time of fixed fire extinguishing devices and other fire control It means the response time of fire smoke. Calculation process requires the use of a subsystem, subsystem 3 is set according to the fire scene and provided Given fire scenario calculated fire smoke temperature, concentration and flow rate. The reference to the relevant part of the Fire Code, ISO /TC21 fixed fire extinguishing system related standards, combined with setting a fire scene When using these standards do engineering judgment, to assess the effect of different fire fighting equipment fire heat release rate. This section also uses engineering methods important output (detection time, start time and extinguishing system performance) was evaluated subsystem 4 Assessment and details the physical and chemical processes need to be considered in the evaluation process, evaluation methods, and evaluate information needed to assess the conclusions. Fire Safety Engineering Guidelines Part 4. detection, and fire started

1 Scope

GB/T 31540 provisions of this part of the engineering analysis of building automatic fire facilities for automatic fire detection alarm system Computation time and automatic fire extinguishing system start-up time, and to assess the effectiveness of automatic fire extinguishing system. This section does not consider the impact of human intervention on the probe, and start the fire.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 5907 (all parts) Fire Vocabulary GB/T 31540.1 Fire Safety Engineering Guide Part 1. Performance of Application Design (GB/T 31540.1-2015, ISO /T R13387-1, MOD) GB 50084 sprinkler system design specifications

3 Terms and Definitions

GB/T 5907 defined by the following terms and definitions apply to this document. 3.1 Start time activationtime From the sensor to respond to the fire extinguishing system, smoke control system, alarm system or other time interval fire protection system prior to full operation. 3.2 The actual water density actualdistributiondensity; ADD Nozzle to spray water flow rate has a certain heat release rate of the combustible surface. 3.3 Spray mouth agentoutlet Media Outlet location sprinkler, fire control devices or other fixed fire extinguishing system. 3.4 Control sprinklers control-modesprinkler By making the fuel becomes wet way to limit the A spray head type (such as plain nozzle or spray nozzle) the spread of fire. 3.5 Normal head conventionalsprinkler So that 40% to 60% of the total amount of water sprayed down sprinklers. 3.6 Detection time detectiontime The time required to detect fire automatically or manually from a fire to occur.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 31540.4-2015_English be delivered?

Answer: Upon your order, we will start to translate GB/T 31540.4-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 31540.4-2015_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 31540.4-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.