GB/T 31540.3-2015 English PDFUS$319.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 31540.3-2015: Fire safety engineering guide -- Part 3: Structural response and fire spread beyond the enclosure of origin Status: Valid
Basic dataStandard ID: GB/T 31540.3-2015 (GB/T31540.3-2015)Description (Translated English): Fire safety engineering guide -- Part 3: Structural response and fire spread beyond the enclosure of origin Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: C84 Classification of International Standard: 13.220.01 Word Count Estimation: 15,133 Date of Issue: 2015-05-15 Date of Implementation: 2015-08-01 Quoted Standard: GB/T 5907.1; GB/T 5907.2; GB/T 5907.3; GB/T 5907.4; GB/T 5907.5; GB/T 9978.1; GB/T 31540.1; GB/T 31540.2 Adopted Standard: ISO/TR 13387-6-1999, MOD Regulation (derived from): National Standard Announcement 2015 No. 15 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This Standard provides a framework for engineering calculation. This section applies to predict structural building elements under fire conditions, fire caused by the response, as well as the spread of fire inside the building and between buildings. GB/T 31540.3-2015: Fire safety engineering guide -- Part 3: Structural response and fire spread beyond the enclosure of origin---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. . Fire safety engineering guide Part 3. Structural response and fire spread beyond the enclosure of origin ICS 13.220.01 C84 National Standards of People's Republic of China Fire Safety Engineering Guidelines Part 3. Indoor and structural response External fire spread Part 3. Structuralresponseandfirespreadbeyondtheenclosureoforigin (ISO /T R13387-6.1999, Firesafetyengineeringguide- Part 6. Structuralresponseandfirespreadbeyond theenclosureoforigin, MOD) Issued on. 2015-08-01 2015-05-15 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordGB/T 31540 "Fire Safety Engineering Guidelines" consists of the following components. --- Part 1. Performance-based design application; --- Part 2. fire, smoke generation and development; --- Part 3. Structural Response and indoor fires spread outside; --- Part 4. detection, and fire started; This section GB/T Part of 331,540. This standard was drafted in accordance with GB/T 1.1-2009 given rules. This section uses redrafted law revision using ISO /T R13387-6. Room 1999 "Fire Safety Engineering structural response and closed fire Foreign spread. " This part of ISO /T R13387-6.1999 compared to the structure have more adjustment, listed in Appendix A of this part of the ISO / TR13387-6.1999 Number of reg control list. This part of ISO /T R13387-6.1999 technical differences exist compared to the terms of these differences has been involved through its outer margin Vertical single line blank position (|) have been marked, in Appendix B gives the corresponding list of technical differences and their causes. This section also made the following editorial changes. --- Deleted international standards foreword, preface redrafted; --- Modify the introduction of international standards, as a part of this introduction; --- International standard "this International Standard" be replaced by "this section; --- The International Standard some punctuation modified to comply with the Chinese habit of punctuation. This section presents the People's Republic of China Ministry of Public Security. This part of the National Standardization Technical Committee on Fire Building Fire Safety Engineering at the Technical Committee (SAC/TC113/SC13) Centralized. This section is responsible for drafting unit. Ministry of Public Security of Sichuan Fire Research Institute. Participated in the drafting of this section. Fire Safety Performance Appraisal Co., Ltd., Sichuan Belfast. The main drafters of this section. Zhang Xiaoming, Lu Guojian, a Xie Yuan, Wang Liping, Liu Junjun, Wu Ping, Wang Jiong, Liu Zhijian.IntroductionWhether it is a "prescriptive" provisions or performance-based fire safety design methods, should ensure that building components can be prevented or delayed Fire spread and structural failure; to ensure that the spread of fire and structural failure does not threaten the safety of people in buildings and fire rescue personnel, It does not affect the achievement of other fire safety objectives. "Prescriptive" fire safety design commonly used building components resistance test methods GB/T 9978.1 prescribed to determine building elements Fire resistance standard criterion mainly refractory stability, fire insulation and fire integrity. Fire codes in our country in general, according to Jian Use buildings, the height of the fire district and the size of the building, on the fire resistance of building elements requested. This section is part of the overall assessment of the fire safety system. Using the calculation method given in this part of the project, in a representative Under the conditions set fire scenarios, calculate building components for thermal and mechanical response of the fire response. On this basis, the use of appropriate assessment criteria Fire spread trends and assess the possibility of structural failure. This section for professionals engaged in fire safety engineering design personnel including fire, fire and rescue personnel, and standardize standards Who, insurers, fire safety management and risk management, standard user should fully understand the calculation method given in this section related Meaning and application conditions parameters. Fire Safety Engineering Guidelines Part 3. Indoor and structural response External fire spread1 ScopeGB/T 31540 Part of the assessment is divided into the hazard of fire and the extent of structural fire spread direction, and the corresponding fire safety measures The effectiveness of the provisions of the framework applied engineering calculation methods. This section applies to predict structural response of building components under conditions of fire caused by the fire, and the fire inside the building and construction The spread of material between.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 5907 (all parts) Fire Vocabulary GB/T 9978.1 building components resistance test methods - Part 1. General requirements (GB/T 9978.1-2008, ISO 834-1. 1999, MOD) GB/T 31540.1 Fire Safety Engineering Guide Part 1. Performance of Application Design (GB/T 31540.1-2015, ISO /T R13387-1.1999, MOD) GB/T 31540.2 Fire Safety Engineering Guidelines - Part 2. fire, smoke generation and development (GB/T 31540.2- 2015, ISO /T R13387-4.1999, MOD)3 Terms and DefinitionsGB/T 5907 defined by the following terms and definitions apply to this document. 3.1 Building components buildingelement Part of the building structure, including floors, walls, beams, columns, doors, etc., but not within the storage building. 3.2 Closed from enclosure The building components from the enclosed space. 3.3 Mechanical Response mechanicalresponse Buildings member offsets the change in the fire, stiffness and stability of the change, fire or building material shrinkage (expansion), stripping Buildings member down, hierarchical and other reasons caused by the opening (crack) changes. 3.4 Thermal Response thermalresponse The melting process of cracking fire in the building component changes in temperature, as well as building components affected by the high temperature of the fire. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 31540.3-2015_English be delivered?Answer: Upon your order, we will start to translate GB/T 31540.3-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 31540.3-2015_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 31540.3-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |