Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 30704-2014 English PDF

US$534.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 30704-2014: Surface chemical analysis -- X-ray photoelectron spectroscopy -- Guidelines for analysis
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 30704-2014534 Add to Cart 3 days Surface chemical analysis -- X-ray photoelectron spectroscopy -- Guidelines for analysis Valid

Similar standards

GB/T 40244   GB/T 35930   GB/T 35924   GB/T 30702   GB/T 30703   GB/T 30701   

Basic data

Standard ID: GB/T 30704-2014 (GB/T30704-2014)
Description (Translated English): Surface chemical analysis -- X-ray photoelectron spectroscopy -- Guidelines for analysis
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: G04
Classification of International Standard: 71.040.40
Word Count Estimation: 27,264
Date of Issue: 6/9/2014
Date of Implementation: 12/1/2014
Quoted Standard: ISO/IEC 17025; ISO 18115-1
Adopted Standard: ISO 10810-2010, IDT
Regulation (derived from): National Standards Bulletin No. 11 of 2014
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard applies to X-ray photoelectron spectroscopy analysis of a representative sample of the operator. This standard helps the operator to complete the analysis process, including sample handling, spectrometer calibration and settings as well as a

GB/T 30704-2014: Surface chemical analysis -- X-ray photoelectron spectroscopy -- Guidelines for analysis


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Surface chemical analysis-X-ray photoelectron spectroscopy. Guidelines for analysis ICS 71.040.40 G04 National Standards of People's Republic of China Surface chemical analysis X-ray photoelectron spectroscopy Guide (ISO 10810.2010, IDT) Issued on. 2014-06-09 2014-12-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Preface Ⅰ Introduction Ⅱ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 Symbols and abbreviations 1 5 Sample Analysis Overview 2

6 Sample Characterization

6.1 Overview 3 6.2 Sample Form 4 6.3 Material Type 5 6.4 Sample handling and installation of 6 6.5 Sample Preparation 6 7 7 verification instrument 7.1 Overview 7 7.2 Check the instrument 7 8 7.3 Instrument Calibration 7.4 Instrument settings 12 8 wide spectrum of scanning 13 8.1 Data Collection 13 8.2 Data Analysis 14 9 narrow scanning 15 9.1 Overview 15 9.2 Data Collection 15 9.3 Data Analysis 15 10 18 Test Report References 20

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard uses the translation method identical with ISO 10810.2010 "Surface chemical analysis - X-ray photoelectron spectroscopy Guide." Correspondence between the consistency of the standards of international documents and normative references of the following documents. --- GB/T 27025-2008 testing and calibration laboratories General requirements (ISO /IEC 17025.2005, IDT) --- GB/T 22461-2008 Surface chemical analysis - Vocabulary (ISO 18115.2001, IDT) The standard micro-beam analysis by the National Standardization Technical Committee (SAC/TC38) and focal points. This standard was drafted. Institute of Chemistry. Drafters of this standard. Zhaozhi Juan, Liu Fen, Zhao Liang-Zhong, Zhang Xiao Yu.

Introduction

X-ray photoelectron spectroscopy (XPS) has been widely used for surface analysis of materials. The measured core level binding energy and binding energy of various elements Table control to identify the elements in the sample (except for H, He). Comparison with the data of pure elemental, chemical shifts are based on state may peak And changes in other parameters to determine. Quantitative information elements obtained from the intensity of the peak in the electronic metering. The use of formulas and equipment manufacturers to provide Or relative sensitivity factors and the appropriate software. The measuring instrument can calculate the measured content of the surface layer of each chemical component. This standard is intended to help the X-ray photoelectron spectroscopy operator for effective and meaningful analysis of typical samples. Surface chemical analysis X-ray photoelectron spectroscopy Guide

1 Scope

This standard applies to X-ray photoelectron spectroscopy analysis of a representative sample of the operator. This standard helps the operator to complete the entire analyzed Cheng, including sample handling, spectrometer calibration and settings as well as a wide collection scanning spectrum and narrow spectral scanning, and gives quantitative and prepare the final report Suggest.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. ISO /IEC 17025 General requirements for testing and calibration laboratories (Generalrequirementsforthecompetenceof testingandcalibrationlaboratories) ISO 18115-1 Surface chemical analysis - Vocabulary - Part 1. General terms and spectrum of academic language (Surfacechemical analysis-Vocabulary-Part 1. Generaltermsandtermsusedinspectroscopy)

3 Terms and Definitions

Terms and definitions defined in ISO 18115-1 apply to this document.

4 Symbols and Abbreviations

The following symbols and abbreviations apply to this document. AES Auger electron spectroscopy (Augerelectronspectroscopy) ARXPS variable-angle X-ray photoelectron spectroscopy (Angle-resolvedX-rayphotoelectronspectroscopy) The amount of the Advisory Committee CCQM substance (Consultativecommitteeforamountofsubstance) CRM certified standard (reference) substance (Certifiedreferencematerial) EAL effective attenuation length (Effectiveattenuationlength) FAT fixed energy analyzer (Fixedanalysertransmission) FRR fixed reduction ratio (Fixedretardratio) FWHM half height width (Fulwidthathalfmaximum) IERF intensity/energy response function (Intensity/energyresponsefunction) NIST National Institute of Standards and Technology (NationalInstituteofStandardsandTechnology) NPL National Physical Laboratory (NationalPhysicalLaboratory) RM standard (reference) substance (Referencematerial) RSD remaining (residual) standard deviation (Residualstandarddeviation) S/N noise ratio (Signaltonoiseratio) XPS X-ray photoelectron spectroscopy (X-rayphotoelectronspectroscopy)
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 30704-2014_English be delivered?

Answer: Upon your order, we will start to translate GB/T 30704-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 30704-2014_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 30704-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.