Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 29907-2013 English PDF

US$198.00 · In stock
Delivery: <= 1 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 29907-2013: Test method for water tightness of curtain walls under dynamic wind pressure
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 29907-2013198 Add to Cart 1 days Test method for water tightness of curtain walls under dynamic wind pressure Valid

Similar standards

GB/T 38264   GB/T 38388   GB/T 34555   GB/T 30661.10   GB/T 30595   GB/T 29908   

Basic data

Standard ID: GB/T 29907-2013 (GB/T29907-2013)
Description (Translated English): Test method for water tightness of curtain walls under dynamic wind pressure
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: P32
Classification of International Standard: 91.060.10
Word Count Estimation: 14,152
Quoted Standard: GB/T 15227; GB 50009
Adopted Standard: AAMA 501.1-2005, NEQ; ENV 13050-2000, NEQ
Regulation (derived from): National Standards Bulletin 2013 No. 23
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the role of building walls dynamic pressure water tight performance terms and definitions, the detection principle, detection devices, specimen and installation, testing, test results and determine the test report. This standard ap

GB/T 29907-2013: Test method for water tightness of curtain walls under dynamic wind pressure

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Test method for watertightness of curtain walls under dynamic wind pressure ICS 91.060.10 P32 National Standards of People's Republic of China Building walls dynamic wind pressure water tight performance Detection method Issued on. 2013-11-27 2014-08-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Preface Ⅰ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 detection principle 1 5 detection device 2 6 specimens and installation 4 7 4 Detection 8 test results determined 5 9 Test Report 5 Appendix A (normative) Calibration of the propeller fan speed of 6 Appendix B (normative) Calibration axial fan means wind 8 Annex C (informative) building walls of dynamic wind pressure water tight performance test report 10

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard reference AAMA501.1-2005 "building windows, walls and doors dynamic pressure water tight performance standard testing methods" ENV13050-2000 "walls - watertightness - laboratory under dynamic air pressure and water spray test conditions." The standard proposed by the Ministry of Housing and Urban-Rural Development of the People's Republic of China. This standard by the national building curtain wall windows and doors Standardization Technical Committee (SAC/TC448) centralized. This standard drafting unit. China Academy of Building Research, Guangdong Academy of Building Research, Shanghai Institute of Building Sciences (Group) have Limited, Jiangsu Academy of Building Research Co., Ltd., Shenzhen City, mountain walls Technical Advisory Co., Ltd., China Building Material Test Certification Center, Shenzhen Institute of Building Sciences, Beijing University of Technology, the State Building Materials Industry Building Hardware Plumbing Products Quality Supervision and Testing Center, Henan Academy of Building Research Co., Ltd., Shanghai doors and windows Testing Station, Guangzhou Academy of Building Research Co., Ltd., Hangzhou Zhijiang Silicone Chemicals Co., Ltd., Shenyang Yuanda Aluminum Industry Engineering Co., Ltd., Guangdong Kin Long Hardware Products Co., Ltd., Zhengzhou Zhongyuan application technology Art Research and Development Co., Ltd., Zhongshan Shengxing Co., Ltd., Guangzhou aluminum Decoration Engineering Co., Beijing Jangho Company Limited Division, Beijing Jiayu Fenestration Co., Ltd., Fujian Nanping Aluminum Co., Ltd., Shenzhen Fu Cheng Curtain Wall Decoration Engineering Co., Ltd., Shenzhen Shenzhen Fangda Decoration Engineering Co., Ltd., Shenzhen Tairan Aluminum Engineering Co., Ltd., Shenzhen Hui Hua Decoration Engineering Co., Ltd., Zhejiang Century Engineering Testing Co., Ltd., Ningbo and State Detection Research Ltd, Hainan Construction Engineering Corporation, Shenyang canon aluminum building system Limited. The main drafters of this standard. Wang Hongtao, Hao Zhihua, Zhang Shixiang, Xu Qin, Zhang Yunlong, DU Ji Yu, Liu Haibo, Luo Gang, SUN Shi Bing, Deng Guizhi, Yangyan Fang, Shi Bo, the Xingyu Fan, Liu, Wang Shuangjun, white Bao Kun, Choi, Jiang Qinghai, Chen Weiming, Guoxin Ya, Zhang Guofeng, Fan Yuling, Xie Guangyu, Zhou Hui, Zeng Wu, Su Shu, Wang Haijun, Gu Jianying, Qin Jian, Guo Zewen, Xiangdong. Building walls dynamic wind pressure water tight performance Detection method

1 Scope

This standard specifies the construction curtain wall dynamic pressure in the water tight performance of terms and definitions, the detection principle, the detection device, specimen and safety Installation, testing, test results and determination test report. This standard applies to building walls in the dynamic wind pressure watertight performance laboratory testing. Detection object confined walls of the specimen Body, does not involve the joints between walls and other structures. Building exterior doors watertight laboratory performance under dynamic wind pressure can be detected Referring to this standard.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 15227 building walls airtight, watertight, wind pressure resistance detection method GB 50009 building structural load specifications

3 Terms and Definitions

GB/T 15227 and defined by the following terms and definitions apply to this document. 3.1 Calibration Winds calibrationwindspeed The average wind speed calibration point. 3.2 Dynamic pressure dynamicwindpressure In the air disturbance under the action of the inner and outer walls on both sides of the specimen formed by wind pressure. 3.3 Dynamic wind pressure water tight performance watertightnessperformanceunderdynamicwindpressure Dynamic pressure watertight performance In the dynamic wind pressure, wall to prevent rainwater from entering the room capacity. 3.4 Propeller law testmethodusingaircraftpropeler The use of aircraft propeller wind dynamic pressure as the system detects a curtain dynamic pressure method for watertight performance. 3.5 Axial fans Act testmethodusingaxialfan Use as a dynamic pressure axial fan air curtain system detects the dynamic pressure method for watertight performance.

4 detection principle

The outer surface of the specimen in accordance with the uniform water continued watering, so that the specimen surface to form a continuous film of water, the outer surface of the specimen is applied to move
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 29907-2013_English be delivered?

Answer: Upon your order, we will start to translate GB/T 29907-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically in 24 hours. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 29907-2013_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 29907-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?