GB/T 28198-2011 English PDFUS$399.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 28198-2011: Ventilator for windows Status: Valid
Basic dataStandard ID: GB/T 28198-2011 (GB/T28198-2011)Description (Translated English): Ventilator for windows Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: K65 Classification of International Standard: 29.020 Word Count Estimation: 17,142 Date of Issue: 2011-12-30 Date of Implementation: 2012-09-01 Quoted Standard: GB/T 191; GB 1002; GB 1003; GB 2099.1; GB/T 2423.3; GB/T 2423.17-2008; GB/T 2828.1-2003; GB/T 2829-2002; GB/T 2900.29-2008; GB/T 3667.1-2005; GB/T 3667.2-2008; GB/T 4214.1-2000; GB 4706.1-2005; GB 4706.27-2008; GB/T 5023.5; GB/T 5089-2008; GB 5296.2; GB/T 7106-2008; GB 9816-2008; GB 15092.1; GB 15092.2; GB 19606-2004; GB/T 19889.10-2006; JZ/T 20 Regulation (derived from): Announcement of Newly Approved National Standards No. 23 of 2011 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the window of household and similar purposes with power ventilation of terms and definitions, product classification, technical requirements, test methods, inspection rules and signs, packaging, transportation and storage. This standard applies to non- power-driven natural ventilation window with the relevant requirements. This standard does not apply to window exhaust fan, wall exhaust fan and exhaust fan duct connection. GB/T 28198-2011: Ventilator for windows---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Ventilator for windows ICS 29.020 K65 National Standards of People's Republic of China Power windows with ventilators Issued on. 2011-12-30 2012-09-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Table of ContentsIntroduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 2 4 Product Category 2 5 2 Technical Requirements Test Method 5 6 7 7 inspection rules 8 signs, packaging, transportation and storage 10 Appendix A (informative) Model naming 12ForewordThis standard was drafted in accordance with GB/T 1.1-2009 given rules. The standard proposed by China National Light Industry Council. This standard by the National Standardization Technical Committee appliances (SAC/TC46) centralized. This standard was drafted. Guangzhou CVC Technology Research Institute detection, Foshan Quality Supervision and Inspection Center, Shanghai Entry-Exit Inspection and Quarantine Bureau of Mechanical and Electrical Products Testing Center, Shanghai, Czech Republic open walls and windows Engineering Co., Ltd., Guangdong Midea Electric Manufacturing Co., environment, Guangdong is Wild Electric Co., Ltd., Guangzhou Zhubang Building Materials Development Co., 丝吉利娅奥 Peter windows Hardware (Beijing) Co., Ltd. The main drafters of this standard. Chen Hangui, Zhangzhao Zhi, Xu Sheng, Wang Pan, Xu Jiayou, Liu Yanping, Sun Ming Dong Wu suggestions, Wang Yusheng, Liu Hui. Power windows with ventilators1 ScopeThis standard specifies the window for household and similar use of terms and definitions power ventilation, product classification, technical requirements, test methods, inspection Inspection rules and signs, packaging, transportation and storage. This standard applies to non-powered natural ventilation window with the relevant requirements. This standard does not apply to the window exhaust fan, exhaust fan and wall duct connected to the exhaust fan. This window contains the standard safety requirements with power ventilation shall comply with the criteria in Table 4, the relevant provisions of Table 5.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 191 Packaging - Pictorial signs GB 1002 Household and similar single-phase plugs and socket type, basic parameters and dimensions GB 1003 Household and similar three-phase plug and socket type, basic parameters and dimensions GB 2099.1 plugs and sockets for household and similar purposes - Part 1. General requirements GB/T 2423.3 Environmental testing for electric and electronic products Part 2. Test methods - Test Cab. Damp heat test GB/T 2423.17-2008 Environmental testing for electric and electronic products Part 2. Test methods - Test Ka. Salt GB/T 2828.1-2003 Sampling procedures for inspection technology - Part 1. by acceptance quality limit (AQL) retrieval batch inspection sampling plan GB/T 2829-2002 periodic inspection Sampling procedures and tables (suitable for process stability test) GB/T 2900.29-2008 Electrotechnical terminology - Household and similar electrical appliances GB/T 3667.1-2005 AC motor capacitors - Part 1. General - Performance, testing and rating Safety requirements for installation And operating guidelines GB/T 3667.2-2008 AC motor capacitors - Part 2. Motor start capacitors Test Methods formula Part 1 GB/T 4214.1-2000 Acoustics Noise Household and similar electrical appliances. General requirements Safety - Part 1 General requirements GB 4706.1-2005 household and similar electrical appliances Part 2 GB 4706.27-2008 Safety of household and similar electrical appliances. Particular requirements for fans GB/T 5023.5 rated voltage of 450/750V and below PVC insulated cables Part 5. Flexible cables (cords) GB/T 5089-2008 AC fan motors General technical conditions GB 5296.2 consumer use - Part 2. Household and similar electrical appliances GB/T 7106-2008 building external doors and windows airtight, watertight, wind pressure performance classification and test methods Requirements and application guide GB 9816-2008 thermal fuse of the GB 15092.1 Switches for appliances - Part 1. General requirements GB 15092.2 Switches for appliances - Part 2. Particular requirements for cord switches GB 19606-2004 Household and similar electrical noise limits GB/T 19889.10-2006 buildings and building elements Acoustics Measurement of sound insulation - Part 10. Small airborne sound insulation of building elements Laboratory measurements ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 28198-2011_English be delivered?Answer: Upon your order, we will start to translate GB/T 28198-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 28198-2011_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 28198-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |