GB/T 27602-2011 English PDFUS$229.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 27602-2011: Measurement of radiofrequency sensitivity for industrial electric detonator Status: Valid
Basic dataStandard ID: GB/T 27602-2011 (GB/T27602-2011)Description (Translated English): Measurement of radiofrequency sensitivity for industrial electric detonator Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: G89 Classification of International Standard: 71.100.30 Word Count Estimation: 10,179 Date of Issue: 2011-12-05 Date of Implementation: 2012-05-01 Quoted Standard: GB 8031; GB/T 13808; GB/T 21652; GJB/Z 377A-1994 Regulation (derived from): Announcement of Newly Approved National Standards No. 19 of 2011 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the industrial electric detonators RF sensitivity measurement principle, apparatus, equipment and installations, test conditions, sample preparation and testing procedures. This standard applies to the determination of industrial electric detonators on the 0. 3GHz ~ 18GHz frequency (continuous wave) of sensitivity. Other uses of the public electricity detonator may refer to the use. GB/T 27602-2011: Measurement of radiofrequency sensitivity for industrial electric detonator---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Measurement of radiofrequency sensitivity for industrial electric detonator ICS 71.100.30 G89 National Standards of People's Republic of China Industrial electric detonator RF sensitivity measured Issued on. 2011-12-05 2012-05-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThis standard is based on GB/T 1.1-2009 of rules for the preparation. The standard proposed by the Ministry of Industry and Information Technology of the People's Republic of China. This standard is under the jurisdiction of the Ministry of Industry and Information Technology Standardization Technical Committee Explosive Materials. This standard was drafted. China North Industries Group, the second thirteen Institute. The main drafters of this standard. Wang Kui-wide, closed Ome, Ni Jingling, India Yu Lei, Wang Liping, Ding Min, Zhangchun Ting, Wang Jianhua, Hu Yaping, Liu Tianxin, Zhao group, Yao Hongzhi, Jixiang Fei. Industrial electric detonator RF sensitivity measured1 ScopeThis standard specifies the principles of industrial electric detonator RF sensitivity measurement, instruments, equipment and devices, test conditions, sample preparation and testing procedures. This standard applies to the determination of industrial electric detonators sensitivity of 0.3GHz ~ 18GHz frequency (continuous wave). Man Ray electricity for other purposes Referring tube can be used.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member, undated references, the latest edition (including any amendments) applies to this document. GB 8031 \u200b\u200bindustrial electric detonator GB/T 13808 copper and copper alloy extruded rod GB/T 21652 Copper and copper alloy wire GJB/Z377A-1994 Sensitivity Test with Mathematical Statistics Principle 3 In shielded room, with the test frequency and output power adjustable RF sources, the matching means, for industrial electric detonators RF power is applied. use Basic RF sensitivity tests to determine the industrial electric detonators each ignition mode ignition sensitivity to different frequencies of the basic RF power; RF statistical sense Test to determine the industrial electric detonators at sensitive frequencies and mode or angry at the frequency of interest and 50% of each combustion mode angry shot Frequency power and its standard deviation, extrapolated from a given confidence level and probability of ignition and do not respond to angry RF power. Block diagram of the test system see picture 1. figure 1 4 apparatus, equipment and apparatus Apparatus, equipment and apparatus used shall meet the following requirements. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 27602-2011_English be delivered?Answer: Upon your order, we will start to translate GB/T 27602-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 27602-2011_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 27602-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |