GB/T 27598-2011: Photographic chemicals -- Measurement methods of the trace elements in the inorganic compounds -- Inductively coupled plasma atomic emission spectrometry (ICP-AES)
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 27598-2011259 Add to Cart 3 days Photographic chemicals -- Measurement methods of the trace elements in the inorganic compounds -- Inductively coupled plasma atomic emission spectrometry (ICP-AES) Valid

Similar standards

GB/T 40260   GB 38508   HG/T 3009   GB/T 41965   GB/T 41964   GB/T 32696   

Basic data

Standard ID: GB/T 27598-2011 (GB/T27598-2011)
Description (Translated English): Photographic chemicals -- Measurement methods of the trace elements in the inorganic compounds -- Inductively coupled plasma atomic emission spectrometry (ICP-AES)
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: G84
Classification of International Standard: 37.040.30
Word Count Estimation: 11,118
Date of Issue: 2011-12-05
Date of Implementation: 2012-03-01
Quoted Standard: GB/T 602; GB/T 4470-1998; GB/T 6682; GB/T 12806; GB/T 12808; GB/T 14666; HG/T 3921; JJG 768-2005
Regulation (derived from): Announcement of Newly Approved National Standards No. 19 of 2011
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the photographic inorganic iron (Fe), copper (Cu), lead (Pb), bismuth (Bi), manganese (Mn), zinc (Zn), tin (Sn), Nickel (Ni), chromium (Cr), cadmium (Cd), cobalt (Co) and other 11 kinds of trace elements in inductively coupled plasma atomic emission spectrometry (hereinafter referred to as ICP-AES). This standard applies to photographic inorganic iron (Fe), copper (Cu), lead (Pb), bismuth (Bi), manganese (Mn), zinc (Zn), tin (Sn), Nickel (Ni), chromium (Cr), cadmium (Cd), cobalt (Co) and other 11 kinds of trace elements analysis. Other inorganic trace elements in the above analysis, it may refer to this standard. These elements can be measured simultaneously, if the sample is diluted to an appropriate concentration, measuring range from ng/g to ��g/g.

GB/T 27598-2011: Photographic chemicals -- Measurement methods of the trace elements in the inorganic compounds -- Inductively coupled plasma atomic emission spectrometry (ICP-AES)


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Photographic chemicals. Measurement methods of the trace elements in the inorganic compounds. Inductively coupled plasma atomic emission spectrometry (ICP-AES) ICS 37.040.30 G84 National Standards of People's Republic of China Photographic analysis of trace elements in inorganic chemicals Inductively coupled plasma atomic emission spectrometry (ICP-AES) method Inductivelycoupledplasmaatomicemissionspectrometry (ICP-AES) Issued on. 2011-12-05 2012-03-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. The standard proposed by China Petroleum and Chemical Industry Association. The photosensitive material standard by the National Standardization Technical Committee (SAC/TC102) centralized. This standard was drafted. China Lucky Film Group Corporation. The main drafters of this standard. Wang Jun. Photographic analysis of trace elements in inorganic chemicals Inductively coupled plasma atomic emission spectrometry (ICP-AES) method caveat Some chemical reagents used in this test method is toxic and corrosive, a number of testing procedures may lead to dangerous situations, the operator shall Appropriate safety and health practices.

1 Scope

This standard specifies the photographic inorganic iron (Fe), copper (Cu), lead (Pb), bismuth (Bi), manganese (Mn), zinc (Zn), tin (Sn), Nickel (Ni), Chromium (Cr), cadmium (Cd), cobalt (Co) and other 11 kinds of trace elements by inductively coupled plasma atomic emission spectroscopy method (hereinafter referred to as ICP-AES). This standard applies to the photographic inorganic iron (Fe), copper (Cu), lead (Pb), bismuth (Bi), manganese (Mn), zinc (Zn), tin (Sn), Nickel (Ni), ,, Analysis of trace elements chromium (Cr) cadmium (Cd), cobalt (Co) and other 11 kinds. Other inorganic trace elements in the above analysis, it can refer to this standard Associate Executive. These elements can be measured simultaneously, if the sample is diluted to the appropriate concentration, measuring range from ng/g to μg/g.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. Preparation of standard solution of GB/T 602 Determination of impurities in chemical reagents GB/T 4470-1998 flame emission, atomic absorption and atomic fluorescence spectrometry term Laboratory use specifications and test methods GB/T 6682 Analysis GB/T 12806 Laboratory glassware single marking flask GB/T 12808 Laboratory glassware single marking pipette GB/T 14666 analytical chemistry terms HG/T 3921 Chemicals sampling and acceptance rules JJG768-2005 emission spectrometer test procedures

3 Terms and Definitions

GB/T 4470-1998 and GB/T 14666 and as defined in the following terms and definitions apply to this document. 3.1 The detection limit limitofdetection In the analysis wavelength element blank solution continuously measured 11 times the standard deviation of three times. NOTE. rewrite GB/T 4470-1998, defined 3.6.2.3. 3.2 Limit of quantification limitofquantitation In the analysis wavelength element blank solution continuously measured 10 times 11 times the standard deviation.
......