Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 32696-2016 English PDF

US$454.00 ยท In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 32696-2016: Photography -- Determination of residual thiosulfate and other related chemicals in processed photographic materials -- Methods using iodine-amylose, methylene blue and silver sulfide
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 32696-2016454 Add to Cart 4 days Photography -- Determination of residual thiosulfate and other related chemicals in processed photographic materials -- Methods using iodine-amylose, methylene blue and silver sulfide Valid

Similar standards

GB/T 40260   GB 38508   HG/T 3009   GB/T 41965   GB/T 41964   

Basic data

Standard ID: GB/T 32696-2016 (GB/T32696-2016)
Description (Translated English): Photography -- Determination of residual thiosulfate and other related chemicals in processed photographic materials -- Methods using iodine-amylose, methylene blue and silver sulfide
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: G84
Classification of International Standard: 37.040.30
Word Count Estimation: 23,242
Date of Issue: 2016-06-14
Date of Implementation: 2017-01-01
Quoted Standard: GB/T 11501-2008; ISO 10349-1-1992
Adopted Standard: ISO 18917-1999, IDT
Regulation (derived from): National Standard Announcement No. 8 of 2016
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard applies to silver halides of gelatin which are finally fixed and washed with thiosulfate. This standard does not apply to stable black-and-white products, heat-processed films or snap-shot products. The procedures given in this standard are used to detect residual thiosulfate, and the silver densitometer method can also measure the remaining associated polysulfate material. The measurement procedures described in this standard are limited by the stability of the processed photographic material and their limitations are described in Annexes A and B. The residual thiosulfate content is determined by the iodine-amylose method or the methylene blue method, and in the case of a film having a photographic photosensitive layer on both sides or a photographic photosensitive layer on one side and a gelatin back layer on the opposite side.

GB/T 32696-2016: Photography -- Determination of residual thiosulfate and other related chemicals in processed photographic materials -- Methods using iodine-amylose, methylene blue and silver sulfide



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Photography - Determination of residual thiosulfate and other related chemicals in absorbed photographic materials - methods using iodine-amylose, methylene blue and silver sulfide ICS 37.040.30 G84 National Standards of People's Republic of China Photography has been processed on the photographic material left Thiosulfate and other related chemicals Determination of iodine - amylose, Methylene blue and silver sulfide method Photography-Determination ofresidualthiosulfateandotherrelated iodine-amylose, methyleneblueandsilversulfide (ISO 18917..1999, IDT) 2016-06-14 release.2017-01-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China China National Standardization Management Committee released Directory Preface I Introduction II 1 Scope 1 2 normative reference document 1 3 General requirements 1 4 - iodine - amylose method 5 methylene blue method 6 6 silver sulfide method 10 Appendix A (informative) Storage characteristics evaluation 14 Appendix B (informative) Test Method Selection Guide 15 Appendix C (informative) Preparation of 0.2 mol/L sodium hydroxide solution 16 Appendix D (informative) Preparation of 1.000 mol/L sodium thiosulfate standard solution 17 Reference 18

Foreword

This standard is drafted in accordance with the rules given in GB/T 1.1-2009. This standard uses the translation method equivalent to the use of ISO 18917..1999 "photographic processed photographic materials on the remaining thiosulfate and Other related chemicals - Determination of iodine - amylose, methylene blue and silver sulfide. This standard is proposed by the China Petroleum and Chemical Industry Association. This standard is nationalized by the National Standardization Technical Committee for Photographic Materials (SAC/TC102). The drafting unit of this standard. China Lokai Group Co., Ltd. The main drafters of this standard. Wang Jun.

Introduction

This standard is one of the series of specifications for photographic processing. Those who do not have knowledge of chemical applications sometimes use this international standard quasi. Therefore, the use of the letter code symbol system gives a hazard warning and indicates the nature of the hazard. More about harm, operation and these chemistry The details of the product can also be obtained from the manufacturer. Determination of residual thiosulfate and its decomposition products in assessing the adequacy of washing and photographic film, dry board, The long side is useful. Insufficient water washing can cause loss of image density and formation of stains in low density areas. The determination of residual thiosulfate and its related compounds is not sufficient to ensure the permanence of the photographic recording material. Long or Archive storage also consider the surrounding contact with the material, storage environment and other factors. These considerations are found in ISO 3897, ISO 5466, ISO 6051 and ISO 10602. Photography has been processed on the photographic material left Thiosulfate and other related chemicals Determination of iodine - amylose, Methylene blue and silver sulfide method

1 Scope

1.1 This standard provides a detailed description of how to determine the residual thiosulfate and other related chemicals for processed photographic materials. 1.2 This standard applies to the final use of thiosulfate fixation and washing of gelatin silver halide products, this standard does not apply to stable black and white Products, hot-working films or snapshots. The procedures given in this standard are used to detect residual thiosulfates, and the silver densitometer method The residual polysulfate material can be measured. The measurement procedures described in this standard are limited by the stability of the processed photographic material , The limitations of which are described in Appendix A and Appendix B. 1.3 Determination of residual thiosulfate content by iodine-amylose or methylene blue method, photographic layer for both sides, A film or a dry sheet having a gelatin back layer having a photographic light-sensitive layer on its surface, and the amount of thiosulfate contained after processing is only one The coating of the topcoat is about twice that of the sample. Note. The results of this report, see Figure 1, Example 2. 1.4 Iodine - amylose method can be used for barium paper, coated paper and film and dry board. This method is used for films containing the developer and photographic paper. 1.5 methylene blue method can be used for barium photo paper, coated paper and film and dry board, but can not be used for the film containing the developer and photo paper. 1.6 silver sulfide density measurement in a specific test conditions with silver ions from the chemical reaction of silver "stain" products in the thiosulfate Salts, even polysulfates and all other residual chemicals. 1.7 A summary of the method, scope, etc. in tabular form, see Appendix B.

2 normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. GB/T 11501-2008 Photographic density measurement - Part 3. Spectral conditions (ISO 5-3..1995, IDT) ISO 10349-1..1992 Photographic photographic grade - Test methods - Part 1. General terms (Photo - Photo - graphic-gradechemicals-Testmethods-Part 1. General)

3 General requirements

3.1 Safety and Hazards 3.1.1 operation The reagents should be operated in accordance with the health and safety precautions given in the packaging or other information. Correct preparation of reagents The label shall contain the name of the chemical, date of preparation, date of validity, date of re-calibration, name of the preparation and appropriate health and safety precautions Application Reagent emissions comply with environmental regulations.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 32696-2016_English be delivered?

Answer: Upon your order, we will start to translate GB/T 32696-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 32696-2016_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 32696-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.