GB/T 25269-2010 English PDFUS$314.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 25269-2010: Rubber -- Guide to the calibration of test equipment Status: Valid
Basic dataStandard ID: GB/T 25269-2010 (GB/T25269-2010)Description (Translated English): Rubber -- Guide to the calibration of test equipment Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: G40 Classification of International Standard: 83.060 Word Count Estimation: 16,177 Date of Issue: 2010-09-26 Date of Implementation: 2011-08-01 Quoted Standard: GB/T 19000; GB/T 19022; GB/T 27025 Adopted Standard: ISO 18899-2004, IDT Regulation (derived from): National Standard Approval Announcement 2010 No.6 (Total No.161) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the calibration principle. Gives a measure of comprehensive requirements traceability guidelines. Also established the basic principles of dysentery not given Evaluation and measurement calibration interval. The calibration method of various parameters of the rubber test device corresponding reference standards. GB/T 25269-2010: Rubber -- Guide to the calibration of test equipment---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Rubber. Guide to the calibration of test equipment ICS 83.060 G40 National Standards of People's Republic of China Rubber test equipment calibration instructions (ISO 18899.2004, IDT) Issued on. 2010-09-26 2011-08-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Table of ContentsIntroduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 Calibration Principle 1 5 Calibration System 2 2 6 Traceability 7 calibration interval 2 Record 2 8 Uncertainty Evaluation 2 9 10 Adjustment 3 11 Procedure 3 Expression 12 Results 3 13 calibration records 3 14 electrical measurement 4 15 Measure 4 16 fluid. flow, pressure, and density measurement 6 17 optical measuring 6 18 Temperature Measurement 7 19 chemical analysis and reference materials 7 20 relative humidity measurement 7 Force measuring 21 7 22 mass measuring 8 23 8 other measurements 24 9 calibration schedule Appendix A (informative) calibration interval 10 References 11ForewordThis standard is equivalent to international standard ISO 18899.2004 "Rubber Test Equipment Calibration Guide" (in English). This standard is equivalent to translate ISO 18899.2004. For ease of use, this standard made the following editorial changes. a) "this International Standard" by "this standard"; b) Remove international standards foreword. Appendix A of this standard is an informative annex. The standard proposed by China Petroleum and Chemical Industry Association. This standard by the national Common test methods for rubber and rubber goods Technical Committee of Standardization Technical Committee centralized. This standard is drafted by. Friends of the Beijing Instrument Co., Ltd. Shenzhen, Beijing Rubber Industry Research and Design Institute. The main drafters of this standard. HE Cheng. Rubber test equipment calibration instructions1 ScopeThis standard establishes the principle of calibration, it gives a measure of the comprehensive requirements traceability guide, but also established a calibration interval and measurement are not The basic principles of assessing degree of certainty. The calibration method of various parameters of the rubber test equipment references corresponding to the relevant standards.2 Normative referencesThe following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 19000 Quality management systems - Fundamentals and vocabulary (GB/T 19000-2008, ISO 9000.2005, IDT) GB/T 19022 Measurement management systems for measurement processes and measuring equipment (GB/T 19022-2003, ISO 10012. 2003, IDT) GB/T 27025 testing and calibration laboratories General requirements (GB/T 27025-2008, ISO 17025.2005, IDT)3 Terms and DefinitionsTerms and definitions GB/T 19000 and GB/T 19022 for the establishment of units of measurement and the following terms and definitions apply to this standard. Note. The terms and definitions of the standard terms and definitions GB/T 15000.2 given consistent. 3.1 Calibration calibration To determine the magnitude of the measuring instrument indicated by corresponding reference instrument by reproducing a set of actions between magnitude. 3.2 Verify verification For measuring or testing equipment for specific test or calibration and make it in a predetermined allowable error limits. 3.3 Metrological confirmation metrologicalconfirmation To ensure the measuring equipment meets the requirements of a set of operations required for the intended use. 3.4 Calibration System calibrationsystem Quality system, including calibration of test equipment, measurement and confirm any valid reference section.4 principle of calibrationMetrological confirmation generally includes calibration and the necessary adjustments, repair and subsequent recalibration, seal or label. It can also include confirmation Verify that a test instrument a characteristic value, such as a length value. In common terms, the whole confirmation process is believed to be calibrated real A service performed by the laboratory, often conduct the calibration of test equipment is designed to provide more appropriate metrological confirmation to ensure that it complies with the Claim. Calibration is based on this principle. The reference standard (sometimes called transfer standard) measured values \u200b\u200bwith other measurement into Comparing. Transfer calibration values \u200b\u200bfrom internationally recognized standards to a nationally recognized standard (often called primary standards), a series of sub-standard or Transfer standard to measure or test equipment, in order to pass. Measurement traceability through the unbroken chain of calibrations or comparisons with the corresponding chain primary level ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 25269-2010_English be delivered?Answer: Upon your order, we will start to translate GB/T 25269-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 25269-2010_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 25269-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |