GB/T 24839-2018 English PDFUS$519.00 ยท In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 24839-2018: Technical specification of post insulators for 1 000 kV a.c. system Status: Valid
Basic dataStandard ID: GB/T 24839-2018 (GB/T24839-2018)Description (Translated English): Technical specification of post insulators for 1 000 kV a.c. system Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: K48 Classification of International Standard: 29.240.01 Word Count Estimation: 26,256 Date of Issue: 2018-07-13 Date of Implementation: 2019-02-01 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB/T 24839-2018: Technical specification of post insulators for 1 000 kV a.c. system---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Technical specification of post insulators for 1 000 kV acsystem ICS 29.240.01 K48 National Standards of People's Republic of China Replace GB /Z 24839-2009 Technical specification for post insulators for 1000kV AC systems Published on.2018-07-13 Implementation of.2019-02-01 State Market Supervisory Administration China National Standardization Administration issued ContentForeword III 1 Scope 1 2 Normative references 1 3 Terms and Definitions 2 4 General conditions of use 2 5 General technical requirements 3 6 porcelain post insulator 6 7 Factory composite pillar insulator 10 8 composite post insulator 14 9 Packaging, marking, transportation and installation 19 Appendix A (informative) Dimensional characteristics of 1000kV porcelain post insulators for UHV engineering 20ForewordThis standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard replaces GB /Z 24839-2009 "Technical Specifications for Post Insulators for 1000kV AC Systems". Compared with GB /Z 24839-2009, the main technical changes of this standard are as follows. --- Increased the technical requirements for the pillar insulators for the series compensation platform (see 5.2.3); --- Increased the terminology, definitions and technical requirements for factory composite post insulators (see 3.2, Chapter 7). This standard was proposed by the China Electricity Council. This standard is under the jurisdiction of the National UHV AC Transmission Standardization Technical Committee (SAC/TC569). This standard is mainly drafted by. State Grid Corporation, China Electric Power Research Institute Co., Ltd. Participated in the drafting of this standard. Xi'an High Voltage Electric Apparatus Research Institute Co., Ltd., Fushun Electric Porcelain Manufacturing Co., Ltd., Hebei Silicon Valley Chemical Co., Ltd. Co., Ltd., Shandong Bianan Power Technology Co., Ltd. The main drafters of this standard. Wu Guangya, Sun Gang, Zhang Rui, Wang Ninghua, Qiu Ning, Li Qingfeng, Wang Xi, Chen Guoqiang, Ji Fang, Deng Tao, Dang Zhenping, Tang Xiaozhong, Song Furu, Luo Rong. The previous versions of the standards replaced by this standard are. ---GB /Z 24839-2009. Technical specification for post insulators for 1000kV AC systems1 ScopeThis standard specifies the general conditions of use, technical requirements, inspection rules, packaging, marking and transportation of 1000kV post insulators. This standard applies to porcelain post insulators used in 1000kV busbars, isolating switches, reactors, series compensation platforms, etc. The factory composite pillar insulator and solid core composite pillar insulator (hereinafter referred to as "insulator"). Pillar insulators for DC systems are also available use. This standard does not include some of the requirements involved in selecting post insulators for specific operating conditions.2 Normative referencesThe following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 197 ordinary thread tolerance Determination of stress-strain properties of GB/T 528 vulcanized rubber or thermoplastic rubber GB/T 529 Determination of tear strength of rubber or thermoplastic rubber (pants, right angles and crescents) GB/T 772 high voltage insulator porcelain parts technical conditions GB/T 1408.1 Test methods for electrical strength of insulating materials - Part 1 GB/T 1462 fiber reinforced plastic water absorption test method GB/T 1692 vulcanized rubber insulation resistivity determination GB/T 1800.1 Product Geometrical Specifications (GPS) Limits and fits Part 1. Basis for tolerances, deviations and fits GB/T 1800.2 Product Geometrical Specifications (GPS) Limits and fits Part 2. Standard tolerance classes and hole and shaft limit deviations Difference table GB/T 2900.5 Electrotechnical terminology for insulating solids, liquids and gases GB/T 2900.8 Electrotechnical terminology insulator Artificial contamination test of high voltage insulators for GB/T 4585 AC system GB/T 6553 Test methods for assessing resistance to electrical traces and s GB/T 8287.1 nominal voltage higher than 1000V system internal and outdoor post insulators Part 1. porcelain or glass insulator Test GB/T 8287.2 nominal voltage higher than 1000V system internal and outdoor post insulators part 2. size and characteristics GB/T 10707 Determination of the burning properties of rubber GB/T 14691 technical drawing font GB/T 16585 vulcanized rubber artificial weathering (fluorescent ultraviolet lamp) test method GB/T 25096 AC voltage is higher than 1000V substation power station pillar composite insulator definition, test method and acceptance criteria GB/T 26218.2 Selection and sizing of high-voltage insulators for use in filth conditions - Part 2. Porcelain and glass for AC systems Glass insulator General technical requirements for silicone rubber insulation materials for DL/T 376 composite insulators DL/T 627 insulator with room temperature curing silicone rubber anti-fouling flash coating Artificial contamination test of composite insulator for DL/T 859 high voltage AC system ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 24839-2018_English be delivered?Answer: Upon your order, we will start to translate GB/T 24839-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 24839-2018_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 24839-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |