GB/T 24561-2009 English PDFUS$169.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 24561-2009: Monitoring and testing for energy saving of drying kiln and hot oven Status: Valid
Basic dataStandard ID: GB/T 24561-2009 (GB/T24561-2009)Description (Translated English): Monitoring and testing for energy saving of drying kiln and hot oven Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: F01 Classification of International Standard: 27.010 Word Count Estimation: 7,743 Date of Issue: 2009-10-30 Date of Implementation: 2010-05-01 Quoted Standard: GB/T 212; GB/T 4272; GB/T 10180 Regulation (derived from): Announcement of Newly Approved National Standards No. 12 of 2009 (No. 152 overall) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the oven drying kiln with energy-saving monitoring projects, test methods and assessment indicators. This standard applies to coal-fired, gas-fired kiln drying and baking ovens. GB/T 24561-2009: Monitoring and testing for energy saving of drying kiln and hot oven---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Monitoring and testing for energy saving of drying kiln and hot oven ICS 27.010 F01 National Standards of People's Republic of China Oven drying kiln and energy monitoring Posted 2009-10-30 2010-05-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordAppendix A of this standard is a normative appendix. This standard by the National Standardization Technical Committee for Energy Management and focal points. This standard was drafted. Tianjin energy monitoring four points, Tianjin Institute of Energy Technology, Industrial Furnace Co., Ltd. Tianjin Saiyo. The main drafters of this standard. Liu Feng, Jia Jun, Ren Changqing, Zhang review, Shangke Wu, Wang Jinxiang, Huoquan Lan, Wangjing Liang, Zhu Tianli, Chen Shan, Chen Fang, Yao Jiaying. Oven drying kiln and energy monitoring1 ScopeThis standard specifies the drying kiln and oven energy monitoring project, monitoring methods and assessment indicators. This standard applies to all kinds of coal, gas and kiln drying oven.2 Normative referencesThe following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. Analysis Method GB/T 212 coal GB/T 4272 General technical equipment and pipeline insulation Performance testing procedures GB/T 10180 industrial boilers Thermal3 Terms and DefinitionsThe following terms and definitions apply to this standard. 3.1 The difference between surface temperature and ambient temperature drying kiln and oven.4 oven drying kiln and energy monitoring projectCheck item 4.1 4.1.1 furnace body tight, complete, equipment and pipe insulation should be consistent with the relevant provisions of GB/T 4272's. 4.1.2 a reasonable set of systems and equipment working properly. 4.1.3 measuring instruments equipped, reasonable, and in the test cycle. 4.2 Test Project 4.2.1 exhaust gas temperature. 4.2.2 air factor. 4.2.3 fired kiln ash carbon content. 4.2.4 furnace surface temperature.5 oven drying kiln and energy monitoring method5.1 Conditions and Monitoring time Monitoring tests should be carried out under the normal operation of equipment, thermal conditions relatively stable situation. Intermittent kilns should be monitored for a complete cycle, even Continued monitoring of kiln no less than 2h. 5.2 Monitoring Instruments Monitoring equipment used to monitor the project should be able to meet the requirements, the instrument should be intact, its accuracy should not be less than the requirements of Table 1 and in the test cycle Inside. Instrument accuracy not less than the value specified in Table 1 of the new instrument, applicable to this standard. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 24561-2009_English be delivered?Answer: Upon your order, we will start to translate GB/T 24561-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 24561-2009_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 24561-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |