GB/T 24131.2-2017: Rubber, raw -- Determination of volatile-matter content -- Part 2: Thermogravimetric methods using an automatic analyser with an infrared drying unit
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 24131.2-2017279 Add to Cart 3 days Rubber, raw -- Determination of volatile-matter content -- Part 2: Thermogravimetric methods using an automatic analyser with an infrared drying unit Valid

Similar standards

GB/T 24131.1   GB/T 20726   GB/T 24153   GB/T 24143   GB/T 24130   

Basic data

Standard ID: GB/T 24131.2-2017 (GB/T24131.2-2017)
Description (Translated English): Rubber, raw -- Determination of volatile-matter content -- Part 2: Thermogravimetric methods using an automatic analyser with an infrared drying unit
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: G40
Classification of International Standard: 83.060
Word Count Estimation: 14,132
Date of Issue: 2017-12-29
Date of Implementation: 2018-07-01
Regulation (derived from): National Standards Bulletin 2017 No. 32
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

GB/T 24131.2-2017: Rubber, raw -- Determination of volatile-matter content -- Part 2: Thermogravimetric methods using an automatic analyser with an infrared drying unit


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Rubber, raw - Determination of volatile-matter content - Part 2. Thermogravimetric methods using an automatic analyzer with an infrared drying unit ICS 83.060 G40 National Standards of People's Republic of China Determination of volatile content of raw rubber Part 2. Infrared drying unit Automatic analyzer heating weight loss method Rubber, raw-Determinationofvolatile-mattercontent- Part 2.Thermogravimetricmethodsusinganautomaticanalyserwith (ISO 248-2.2012, MOD) 2017-12-29 Posted 2018-07-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released

Foreword

GB/T 24131 "raw rubber volatile content determination" is divided into two parts. --- Part 1. Hot roller method and oven method; --- Part 2. Automatic analyzer with infrared drying unit heating weight loss method. This section GB/T 24131 Part 2. This section drafted in accordance with GB/T 1.1-2009 given rules. This section uses the redrafted law Amendment uses ISO 248-2.2012 "Determination of volatile rubber content of raw rubber Part 2. Infrared Line Drying Unit Automatic Analyzer Heat Loss Method "(in English). This part of ISO 248-2.2012 technical differences and the reasons are as follows. --- On the normative references, this section made a technical difference with the adjustment to adapt to China's technical conditions, adjust the situation Concentration reflected in the second chapter "Normative references", the specific adjustments are as follows. โ— Equivalent to the international standard GB/T 5576 instead of ISO 1629; โ— Replace ISO 1795 with GB/T 15340 equivalent to international standards. --- Removed the "test result is a separate volatile content of the measured value", the content and the technical content of this chapter does not conform (See Chapter 6). --- Increasing the butyl rubber and halogenated butyl rubber suitable drying temperature (see 7.2.2, 7.2.3). This part is proposed by China Petroleum and Chemical Industry Federation. This part of the National Rubber and Rubber Products Standardization Technical Committee (SAC/TC35) centralized. This part of the drafting unit. PetroChina Petrochemical Research Institute, Shandong Jingbo Petrochemical Co., Ltd. Rubber Branch, China National Petroleum Corporation Lanzhou Petrochemical Branch, China Petrochemical Co., Ltd. Beijing Yanshan Branch. The main drafters of this section. Jia Hui Qing, Zhai Yueqin, Cui Hongmei, Yang Fang, Chen with Ping, Sun Lijun, Liu Bo Cen, Ren Feng, Liu Sha, Wang Feng Le, ้š— Ning. Determination of volatile content of raw rubber Part 2. Infrared drying unit Automatic analyzer heating weight loss method Caution --- personnel using this section should be familiar with the formal laboratory procedures. This section does not indicate all possible safety issues question. It is the user's responsibility to take appropriate safety and health measures and to ensure compliance with the requirements of the relevant state laws and regulations. Caution --- Some of the steps in this section may involve the use or generated substances or waste generated, causing harm to the local environment, After the test should be handled in accordance with the appropriate documents and disposal.

1 Scope

1.1 GB/T 24131 provisions of this part of the automatic analyzer with infrared drying unit for determination of raw rubber moisture and other volatile Two kinds of heat-weight loss method of sexual material content. 1.2 This section applies to the determination of GB/T 5576 included in the synthetic rubber (SBR, NBR, BR, IR, CR, IIR, BIIR and CIIR And EPDM) volatile content, the rubber shape can be massive, flaky, granular, crumbs, powder and the like. This section also applies to other categories However, in this case, it is necessary to verify that the change in quality is only due to the loss of volatile materials in the raw rubber rather than rubber degradation Due. 1.3 This section does not apply to the inclusion of raw rubber in GB/T 15340 need to be uniform. 1.4 ISO 248-1.2011 hot roller method and oven method with the method of this section may not be able to get the same result. So controversial Case, ISO 248-1.2011 oven method A arbitration. Note. When the automatic analyzer determines the volatility conditions of a certain type or grade of gelatin have been established, both methods can be used for routine testing, such as quality control.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 5576 rubber and latex nomenclature (GB/T 5576-1997, idtISO 1629.1995) GB/T 15340 Natural, synthetic raw gum sampling and sample preparation methods (GB/T 15340-2008, ISO 1795.2000, IDT) ISO 248-1.2011 Determination of volatile rubber content of raw rubber - Part 1. Hot roller method and oven method (Rubber, raw-De- terminationofvolatile-mattercontent-Part 1.Hot-milmethodandovenmethod)

3 principle

Using an automatic analyzer with an infrared drying unit, the sample is continuously weighed until the mass is constant by the heating weight loss method, and according to the measurement procedure The mass loss in the calculation of volatile content.

4 reagent

Sodium L-tartrate dihydrate Standard substance, purity not less than 99%.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 24131.2-2017_English be delivered?

Answer: Upon your order, we will start to translate GB/T 24131.2-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 24131.2-2017_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 24131.2-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.