GB/T 223.9-2008 English PDFUS$259.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 223.9-2008: Iron, steel and alloy -- Determination of aluminium content -- Chrome azurol S photometric method Status: Valid GB/T 223.9: Historical versions
Basic dataStandard ID: GB/T 223.9-2008 (GB/T223.9-2008)Description (Translated English): Iron, steel and alloy -- Determination of aluminium content -- Chrome azurol S photometric method Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: H11 Classification of International Standard: 77.080.01 Word Count Estimation: 11,188 Date of Issue: 2008-05-13 Date of Implementation: 2008-11-01 Older Standard (superseded by this standard): GB/T 223.9-2000; GB/T 223.10-2000 Quoted Standard: GB/T 6379.1; GB/T 6379.2; GB/T 20066 Regulation (derived from): National Standard Approval Announcement 2008 No.8 (Total No.121) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the use Chromazurol S spectrophotometric determination of soluble aluminum and with Cupferron separation-Chromazurol S spectrophotometric determination of aluminum. This section applies to a method of mass fraction for the determination of iron, steel and alloy 0. 050% to 1. 00% acid soluble aluminum content, This section applies to method two steel and alloy for the determination of the mass fraction of 0. 015% to 0. 50% aluminum content. GB/T 223.9-2008: Iron, steel and alloy -- Determination of aluminium content -- Chrome azurol S photometric method---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Iron, steel and alloy. Determination of aluminium content. Chrom azurol S photometric method ICS 77.080.01 H11 National Standards of People's Republic of China Replacing GB/T 223.9 ~ 223.10-2000 Determination of aluminum content of steel and alloy Chromium Azure S Spectrophotometry Posted 2008-05-13 2008-11-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThis section GB/T 223 is to GB/T 223.9-2000 "steel and alloy chemical analysis method Chromium Azure S spectrophotometry Given the amount of aluminum "and GB/T 223.10-2000" steel and alloy chemical analysis method cupferron isolated - Chromium Azure S Spectrophotometry The amount of aluminum, "the integration of amendments. This Part replaces GB/T 223.9-2000 and GB/T 223.10-2000. This portion of the GB/T 223.9-2000, GB/T 223.10-2000 compared primarily with the following modifications. --- Name to "iron, steel and aluminum alloys - Determination of chromium content Azure S Spectrophotometry"; --- Original two standards into a single standard, includes two analysis methods; --- Method one. Modify the preparation of a nickel solution; --- Method Two. Modify the preparation of aluminum standard solution; --- Modify the results of the calculation formula, and the formula in the amount of the unit; --- Change the specification of the precision functional description. Appendix A of this section is informative appendix. This part is proposed by the China Iron and Steel Association. This part of the National Steel Standardization Technical Committee. This section drafted by. China Iron and Steel Research Institute Group, Baoshan Iron & Steel Co., Ltd. Special Steel Branch, Daye steel mills. The main drafters of this section. Cuiqiu Hong, Wang Yujuan, painted Renjie. This part of the standard replaces the previous editions are. --- GB/T 223.9-1982, GB/T 223.9-1989, GB/T 223.9-2000; --- GB/T 223.10-1982, GB/T 223.10-1991, GB/T 223.10-2000. Determination of aluminum content of steel and alloy Chromium Azure S Spectrophotometry Warning. Use of this section shall be a person experiences regular laboratory work. This section does not indicate that all possible security issues. Users have the responsibility to take appropriate safety and health practices and to ensure compliance with the conditions relevant national regulations.1 ScopeThis section GB/T 223 requirements using Chromium Azure S Spectrophotometry Determination of soluble aluminum and copper and iron separation reagent - CAS S Determination of the aluminum content. This section applies to a method for the mass fraction of iron, steel and alloys for the determination of 0.050% to 1.00% acid soluble aluminum content; this section method Not applicable to steel and alloy content was measured 0.015% to 0.50% aluminum content.2 Normative referencesThe following documents contain provisions which, through reference GB/T 223 of this text, constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section. GB/T 6379.1 measurement methods and results of Accuracy (trueness and precision) - Part 1. General principles and definitions GB/T 6379.2 measurement methods and results of Accuracy (trueness and precision) - Part 2. Determine the weight of a standard measurement method The basic method of refolding and reproducibility GB/T 20066 Steel and iron - Sampling and determination of the chemical composition of the sample with a sample preparation method3 a method of direct spectrophotometric Chromium Azure S3.1 Principle After the sample is dissolved by acid at pH (5.3 to 5.9) in acid medium, aluminum and chrome azure S generated purple complex measure Absorbance. Vanadium-containing 100μg color solution, 2mg not interfere with the determination of chromium, iron, nickel interference masking available Zn-EDTA, 300μg titanium available 0.15g mannitol masking. 3.2 Reagents and materials Unless otherwise stated, the analysis using only the confirmation of analytical grade reagents and distilled water or its equivalent purity. 3.2.1 iron, aluminum or known to contain residual aluminum content. 3.2.2 hydrochloric acid, ρ about 1.19g/mL. 3.2.3 hydrochloride, ρ of about 1.19g/mL, diluted to 5 + 95. 3.2.4 nitrate, ρ about 1.42g/mL. 3.2.5 perchloric acid, ρ about 1.67g/mL. 3.2.6 mannitol solution, 50g/L. 3.2.7 hexamethylenetetramine solution, 400g/L, stored in a plastic bottle. 3.2.8 ammonium fluoride solution, 5g/L, stored in a plastic bottle. 3.2.9 Chromium Azure S solution, 0.5g/L. 3.2.10 edetate zinc (Zn-EDTA) solution. Weigh 8.1g of zinc oxide in a beaker, add 40mL of hydrochloric acid (1 + 1) heating the solution ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 223.9-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 223.9-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 223.9-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 223.9-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 223.9-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 223.9-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |