GB/T 22264.5-2022 English PDFUS$279.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 22264.5-2022: Mounted digital display electric measuring instruments - Part 5: Special requirements for phase meters and power factor meters Status: Valid GB/T 22264.5: Historical versions
Basic dataStandard ID: GB/T 22264.5-2022 (GB/T22264.5-2022)Description (Translated English): Mounted digital display electric measuring instruments - Part 5: Special requirements for phase meters and power factor meters Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: N23 Classification of International Standard: 17.220.20 Word Count Estimation: 14,144 Date of Issue: 2022-12-30 Date of Implementation: 2023-07-01 Older Standard (superseded by this standard): GB/T 22264.5-2008 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB/T 22264.5-2022: Mounted digital display electric measuring instruments - Part 5: Special requirements for phase meters and power factor meters---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. ICS 17.220.20 CCSN23 National Standards of People's Republic of China Replace GB/T 22264.5-2008 Installed digital display electrical measuring instrument Part 5.Particular requirements for phase meters and power factor meters Posted on 2022-12-30 2023-07-01 implementation State Administration for Market Regulation Released by the National Standardization Management Committee table of contentsPreface I Introduction III 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Product classification, classification and compliance1 4.1 Category 1 4.2 Classification 2 4.3 Compliance with the requirements of this document 2 5 Technical requirements 2 5.1 Standard power value 2 5.2 Reference conditions and basic errors 2 5.3 Nominal service range and variation 3 5.4 Security requirements 4 5.5 Electrical requirements 4 5.6 Accuracy performance requirements 5 5.7 Electromagnetic Compatibility 5 5.8 Structural requirements 6 5.9 Climate impact6 5.10 Reliability 6 6 Information, general signs and symbols 6 6.1 Information 6 6.2 Signs, symbols and their positions 6 6.3 Marking of nominal service range and reference value or reference range 6 6.4 Signs and symbols of terminals 7 7 Inspection rules 7 8 Packaging, storage and transportation 7 Appendix A (Normative) Test items and recommended sequence 8 Reference 9 Table 1 Reference conditions and allowable deviation 3 Table 2 Limits of Nominal Service Range and Permissible Variation 3 Table 3 Short-time overload5 Table 4 Electromagnetic Disturbance Test Applied Power Requirements 6 Table A.1 Test items and recommended sequence 8forewordThis document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules for Standardization Documents" drafting. This document is part 5 of GB/T 22264 "Installed Digital Display Electrical Measuring Instruments". GB/T 22264 has issued the following part. --- Part 1.Definitions and general requirements; --- Part 2.Special requirements for ammeters and voltmeters; --- Part 3.Special requirements for power meters and reactive power meters; --- Part 4.Special requirements for frequency tables; --- Part 5.Particular requirements for phase meters and power factor meters; --- Part 6.Special requirements for insulation resistance meters; --- Part 7.Special requirements for multi-function instruments; --- Part 8.Test methods. This document replaces GB/T 22264.5-2008 "Mounted Digital Display Electrical Measuring Instruments Part 5.Phase Meter and Power Factor Meter Compared with GB/T 22264.5-2008, except for structural adjustment and editorial changes, the main technical changes are as follows. --- Changed the scope and added "This document is applicable to newly manufactured AC 690V and below, with a nominal frequency of 50Hz or Installed digital display phase meters and power factor meters for measuring various electrical parameters in power distribution systems" (see Chapter 1,.2008 Chapter 1 of the edition); --- Deleted the definition of "phase meter" and "power factor meter" (see 3.1, 3.2 of the.2008 edition); --- Increased the standard power value, specifying the nominal voltage, nominal current, nominal frequency and its range (see 5.1); --- Changed the reference conditions and allowable deviations in Table 1 (see 5.2.1, Table 1 of the.2008 edition). ● Change "voltage component to be measured" to "voltage", reference value or reference range "rated voltage or any voltage within the reference range Voltage (or sometimes)" is changed to "nominal voltage or any voltage within the reference range", and the allowable deviation "±2% of rated value" is changed to is "±1.0%"; ● Change "measured current component" to "current", and the reference value or reference range "40%~100% of rated current" to "40%~100% of the nominal current value or any current within the reference range", change the allowable deviation to "±1.0%"; ● Change “symmetrical voltage and current” to “symmetrical voltage and balanced current”; ● Deleted the special requirements for the influence quantity of "the frequency of the voltage and current components to be measured"; ● Increased "nominal voltage (current) value or reference range, allowed to be proposed by the manufacturer" provisions. --- Changed the nominal use range limits and allowable changes in Table 2 (see 5.3.1, Table 2 of the.2008 edition). ● Change "nominal use range limit" to "nominal use range limit"; ● Change "distortion measured by AC" to "waveform", delete the classification of frequency sensitivity and insensitivity, and limit the nominal use range The unified regulation is. "distortion factor. 20% (except for non-RMS measuring instruments)"; ● Change the "current component to be measured" to "current", and the limit value of its nominal use range to "10%~of the nominal current value 120% or reference current range lower limit -10% and upper limit 10%"; ● Change "measured voltage component" to "voltage", and its nominal use range limit to "±10% of the nominal voltage value, or Reference voltage range lower limit -10% and upper limit 10%"; ● Change the "frequency measured by AC" to "frequency", and the limit of its nominal use range to "±2% of the nominal frequency value, or the reference The lower limit of the frequency range -10% and the upper limit 10%", the allowable change is changed to "±(a%Ux b%Um)"; ● Change "external magnetic field" to "external power frequency magnetic induction". --- Changed the technical requirements of "self-heating" (see 5.5.1, 7.2.1 of the.2008 edition); --- Increased Table 3 "short-time overload" (see 5.5.6.3.2); --- Deleted the conditions for determining the amount of change (see 6.3 of the.2008 edition); ---Change "output interface" to "input and output interface" (see 5.5.5, 7.2.5 of the.2008 edition); --- Changed the immunity test requirements for electromagnetic disturbances (see 5.7.1, 7.4.1 of the.2008 edition). ● The limit value imposed by the voltage circuit and current circuit is changed from the original "full scale value" to "nominal value or upper limit value of reference range". Bit (power factor) magnitude requirements; ● The allowable change caused by electromagnetic compatibility in Table 4 is deleted; ● Added "Table 4 Requirements for Applied Electricity in Electromagnetic Disturbance Test". ---Changed the radio interference suppression test requirements, the limit value imposed by the voltage circuit and current circuit, changed from the original "full scale value" to "nominal value Or the upper limit of the reference range", increase the magnitude requirements of the phase (power factor) (see 5.7.2, 7.4.2 of the.2008 edition); ---Modified the technical requirements for "average life" and changed "average life" to "reliability" (see 5.10, 7.7 of the.2008 edition); --- Added "test items and recommended sequence" (see Appendix A). Please note that some contents of this document may refer to patents. The issuing agency of this document assumes no responsibility for identifying patents. This document is proposed by China Machinery Industry Federation. This document is under the jurisdiction of the National Standardization Technical Committee for Electrical Instrumentation (SAC/TC104). This document is drafted by. Harbin Electrical Instrument Research Institute Co., Ltd., State Grid Hunan Electric Power Co., Ltd. Power Supply Service Center (Metering Center), Wenzhou Institute of Metrology, Shenzhen Kelu Electronic Technology Co., Ltd., Shandong Huake Information Technology Co., Ltd., Zhejiang CHINT IOT Technology Co., Ltd., Shanghai Complee Instrument Co., Ltd., Zhejiang Institute of Metrology, Jiangsu Sfeier Electric Co., Ltd. Company, Zhejiang Tianzheng Electric Co., Ltd., Wasion Information Technology Co., Ltd., State Grid Chongqing Electric Power Company Marketing Service Center, State Grid Shandong Electric Power Company Electric Power Research Institute, Shijiazhuang Kelin Electric Co., Ltd., State Grid Shandong Electric Power Company Marketing Service Center Xin (Measurement Center), China Electrical Instrumentation Quality Supervision and Inspection Center, Huaihua Jiannan Electronic Technology Co., Ltd., Huali Technology Co., Ltd. Company, Ningbo Canaan Intelligent Electric Co., Ltd., Zhejiang Wansheng Intelligent Technology Co., Ltd., Delixi Group Instrument Co., Ltd. Division, Shanghai Belling Co., Ltd., Yunnan Power Grid Co., Ltd., Shandong Provincial Institute of Metrology, Guangdong Boli Technology Co., Ltd., Wuhan Shengfan Electronics Co., Ltd., Qingdao Qiancheng Technology Co., Ltd., State Grid Jibei Electric Power Co., Ltd. Electric Power Research Institute, State Grid Metering Center of Jibei Electric Power Co., Ltd., Marketing Service Center of State Grid Sichuan Electric Power Company, Zhongnan Instrument Co., Ltd., Zhejiang Chentai Technology Co., Ltd., Zhejiang UBS Electronics Co., Ltd., Jiangyin Zhonghe Power Instrument Co., Ltd., Xi'an Xinlinda Digital Technology Co., Ltd. The main drafters of this document. Xiao Yu, Wang Zhi, Zhou Xiaohua, Zheng Mengxia, Yang Huixuan, Liu Xiancheng, Xiong Wei, Ding Zhen, Chen Zhiming, Jiang Yu, Wang Sanqiang, Jiang Bin, Shen Xin, Liu Alloy, Xu Chugong, Cao Tong, Liu Yadong, Zeng Shitu, Liu Haitao, Liu Dan, Shao Fengyun, Wang Ronghua, Li Rongping, Wang Xiaojian, Li Zhengfan, Shan Baohua, Ding Zhengguang, Wang Jia, Ouyang Jinxing, Wang Xinjun, Yang Huijun, Wang Wei, Yang Juexian, Liu Xiao, Gao Shuai, Li Xiaojun, Zhang Enyou, Lin Zichao, Lei Ming, Zhang Jie, Zhen Rongguo, Zhang Zhijin. The release status of previous versions of this document and the documents it replaces. ---First published as GB/T 22264.5-2008 in.2008; --- This is the first revision.IntroductionInstalled digital display electrical measuring instruments are installed in various distribution cabinets and distribution boxes, and are widely used in industrial and mining enterprises, electric power, metallurgy, chemical industry, In fields such as energy, medical care, and transportation, the application scenarios continue to expand. GB/T 22264 series standards have been promulgated and used for more than 10 years. And market changes, the standard can no longer adapt to the development of technology and user needs. GB/T 22264 aims to standardize the technology of installed digital display electrical measuring instruments by combining the latest product technology and user needs at home and abroad. Specifications and safety requirements, and put forward corresponding test methods, to provide a product specification for manufacturers and users of such electrical measuring instruments, It embodies most of the requirements of the technical specification for product ordering. GB/T 22264 is proposed to consist of the following eight parts. --- Part 1.Definitions and general requirements. The purpose is to establish the definitions and common enquiries. --- Part 2.Special requirements for ammeters and voltmeters. The purpose is to develop special requirements for ammeters and voltmeters. --- Part 3.Special requirements for power meters and reactive power meters. The purpose is to formulate special requirements for power meters and reactive power meters. --- Part 4.Special requirements for frequency tables. The purpose is to develop special requirements for frequency tables. --- Part 5.Special requirements for phase meters and power factor meters. The purpose is to formulate special requirements for phase meters and power factor meters. --- Part 6.Special requirements for insulation resistance meters. The purpose is to formulate special requirements for insulation resistance meters. --- Part 7.Special requirements for multi-function instruments. The purpose is to formulate special requirements for multi-function instruments. --- Part 8.Test methods. The purpose is to standardize the test methods for installed digital display electrical measuring instruments. In recent years, the international safety requirements for products have become more and more stringent. This revised standard, combined with IEC 61010-1.2010 and GB/T 17215.211-2021, revised the safety-related content, clarified the terms of use, and improved product safety performance. Installed digital display electrical measuring instrument Part 5.Particular requirements for phase meters and power factor meters1 ScopeThis document specifies the product classification, classification and compliance, technical requirements, information, General signs and symbols, inspection rules, and packaging, storage and transportation. This document is applicable to measuring phase or power of newly manufactured power distribution system with AC below 690V and nominal frequency of 50Hz or 60Hz Installed digital display phase meter and power factor meter for factor, also suitable for phase meter and power factor meter with analog/digital dual display Digital display part. This document does not apply to. --- Phase meter and power factor meter with direct acting analog indication only; ---Portable digital display phase meter and power factor meter; --- There are also national standard (or industry standard) special-purpose phase meters and power factor meters.2 Normative referencesThe contents of the following documents constitute the essential provisions of this document through normative references in the text. Among them, dated references For documents, only the version corresponding to the date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to this document. GB/T 22264.1-2022 Mounted digital display electrical measuring instruments Part 1.Definitions and general requirements3 Terms and DefinitionsThe following terms and definitions defined in GB/T 22264.1-2022 apply to this document. 3.1 A digital display meter for measuring phase. Note. Hereinafter referred to as the phase table. 3.2 Digital display instrument for measuring power factor. Note 1.Hereinafter referred to as the power factor table. Note 2.The phase meter with digital display and the power factor meter with digital display are collectively referred to as instruments below. 4 Product classification, classification and conformity 4.1 Classification It shall meet the provisions of 4.1.3 and 4.1.5~4.1.9 in GB/T 22264.1-2022. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 22264.5-2022_English be delivered?Answer: Upon your order, we will start to translate GB/T 22264.5-2022_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 22264.5-2022_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 22264.5-2022_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 22264.5-2022?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 22264.5-2022 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |