GB/T 22159.2-2012 English PDFUS$554.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 22159.2-2012: Acoustics and vibration -- Laboratory measurement of vibro-acoustic transfer properties of resilient elements -- Part 2: Direct method for determination of the dynamic stiffness of resilient supports for translatory motion Status: Valid
Basic dataStandard ID: GB/T 22159.2-2012 (GB/T22159.2-2012)Description (Translated English): Acoustics and vibration -- Laboratory measurement of vibro-acoustic transfer properties of resilient elements -- Part 2: Direct method for determination of the dynamic stiffness of resilient supports for translatory motion Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: A59 Classification of International Standard: 17.140 Word Count Estimation: 28,255 Quoted Standard: GB/T 2298; GB/T 11349.1; GB/T 14412; GB/T 22159.1-2012; ISO 226; ISO 16063-21; ISO/IEC GUIDE 98-3 Adopted Standard: ISO 10846-2-2008, IDT Regulation (derived from): National Standards Bulletin No. 41 of 2012 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies a given pre- load resilient supports for translatory motion dynamic stiffness method. The method involves blocking the input and output power vibration laboratory measurements, called "direct measurement method. " The method in thi GB/T 22159.2-2012: Acoustics and vibration -- Laboratory measurement of vibro-acoustic transfer properties of resilient elements -- Part 2: Direct method for determination of the dynamic stiffness of resilient supports for translatory motion---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. . Acoustics and vibration Laboratory measurement of vibro-acoustic transfer properties of resilient elements Part 2. Direct method for determination of the dynamic stiffness of resilient supports for translatory motion ICS 17.140 A59 National Standards of People's Republic of China Sound and vibration elastic element vibration - acoustic transfer Characteristics laboratory measuring methods - Part 2. Flexible Direct measurement method supports translational dynamic stiffness propertiesofresilientelements-Part 2. Directmethodfordeterminationofthe (ISO 10846-2.2008, IDT) Issued on. 2012-12-31 2013-06-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Table of ContentsPreface Ⅰ Introduction Ⅱ 1 Scope 1 2 Normative references 2 3 Terms and definitions 2 4 Principle 5 5 Requirements for instruments and equipment 5 The applicability of the guidelines 106 Test Device Step 13 7 Test 8 15 test results calculated 9 record content 17 10 18 Test Report Appendix A (informative) Static load-deformation curve 19 Annex B (informative) Measurement Uncertainty 20 References 23ForewordGB/T 22159 in "sound and vibration elastic element vibration - acoustic transfer characteristic measurement laboratory" divided into the following five sections. --- Part 1. Principles and Guidelines; --- Part 2. Flexible support level Dodo direct measurement approach stiffness; --- Part 3. Flexible support level Dodo indirect measurement method stiffness; --- Part 4. elements other than resilient supports for translatory motion dynamic stiffness; --- Part 5. Determination of elastic supports low-level dynamic driving point dynamic stiffness method. This is Part 2 GB/T 22159 of. This section drafted in accordance with GB/T 1.1-2009 given rules. This part identical with ISO 10846-2.2008 "Acoustics and vibration elastic element vibration - Laboratory measurement of sound transmission characteristics Method Part 2. Elastic support level direct measurement approach "Dodo stiffness. Consistency correspondence between this part of international documents and normative references of our files are as follows. --- GB/T 3240 acoustic measurement commonly used frequency (ISO 226. 1975, NEQ) This section proposed by the Chinese Academy of Sciences. The acoustics in part by the National Standardization Technical Committee (SAC/TC17) centralized. This part mainly drafted by. Institute of Acoustics, Chinese Academy of Sciences, Hefei University of Technology, Nanjing University, Beijing Labor Protection Science Research The Northwestern Polytechnical University, Tongji University, Long Shaao Bang Industrial Co., Ltd. of environmental protection. The main drafters of this section. Lv Yadong, Li Zhiyuan, Qiu Xiaojun, Yang Jun, Chengming Kun, Zhang Bin, Ren Wentang, Chen Kean, Wu Yu Zhou, Mao Dongxing, Mo Jian Yan, Xu Xin, Diao Yin.IntroductionVarious passive elastic support member is used to reduce the transmission of vibration, such as automobile engine mounts, resilient supports building, marine engine The elastic base and a flexible coupling and small household appliances in the isolator. This section provides a direct measurement of linear elastic supporting elements dynamic stiffness function. As long as their performance in a given static preload Approximate linear vibration characteristics, the nonlinear static pre-load - displacement characteristics of the resilient support member may also be measured using this method. Headquarters The elastic element into vibration - acoustic transfer properties of one of the series standard laboratory measurement methods, the series also includes a standard measurement principle, indirectly measured The amount and method of driving point of law related content. Part 1 provides a standard selection criteria applicable to this series of guide portion. Laboratory conditions described in this section involves the use of static preload. This section describes the results obtained by the method adapted to prevent low-frequency vibration and reduce sound structure of the elastic support member. However, this method It can not provide a complete description of further information on the elastic member for attenuating low frequency vibration and shock offsets, the need for additional information to elaborate. Sound and vibration elastic element vibration - acoustic transfer Characteristics laboratory measuring methods - Part 2. Flexible Direct measurement method supports translational dynamic stiffness1 ScopeThis section GB/T 22159 requirements for a given pre-load elastic supports translational movement measuring method stiffness. The method involves input End blocking output force and vibration laboratory measurements, referred to as "direct measurement approach." This method is applicable to a portion of the test element parallel flanges (see Fig. 1). a) b) c) Note 1. If the elastic supporting member does not have a parallel flanges, requires the use of a parallel flange having an auxiliary fixture and test it as a member Points, in order to meet the conditions required for the measurement. Note 2. the load is shown by the arrow direction of FIG.1 with parallel flange elastic supporting member exampleThe elastic element in this section are directed mainly used to reduce. a) the audible sound of low frequency (typical value is between 20Hz ~ 500Hz) of the structure-borne vibration, which can sometimes lead to structural radiation Undesired fluid sound (sound such as air, water, sound, or other media voices). b) low frequency vibration (typical value is between 1Hz ~ 80Hz) can be spread in the human body, or when such vibration is very grave, Any size member hazard. Note 1. In fact, due to the size limit testing device, the method can not be used too big or too small elastic supporting member. Note 2. This method can also be used for continuous sample support member with reed mats and strips constructed. These samples can be fully described in this Part is characteristic of complex systems Sub-user responsibility. This section covers the test element and the vertical flange and parallel translational measurements. Direct measurement of the frequency range applicable law is 1Hz ~ fUL, fUL usually depends on test systems. Note 3. Due to the type of test systems and test element of variety, so fUL usually change. In this section, there is no test system defines a fixed Frequency range, but the actual test data subject, such as the 6.1 to 6.4. This section uses the measurement data obtained by the method can be used. --- Production and supply product information provided by manufacturers; --- The product development process the required information; --- Product quality control; ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 22159.2-2012_English be delivered?Answer: Upon your order, we will start to translate GB/T 22159.2-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 22159.2-2012_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 22159.2-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |