GB/T 19258.2-2023 English PDFUS$499.00 ยท In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 19258.2-2023: Ultraviolet radiation sources for germicidal purpose - Part 2: Cold cathode low pressure mercury vapour discharge lamp Status: Valid
Basic dataStandard ID: GB/T 19258.2-2023 (GB/T19258.2-2023)Description (Translated English): Ultraviolet radiation sources for germicidal purpose - Part 2: Cold cathode low pressure mercury vapour discharge lamp Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: K71 Classification of International Standard: 29.140.30 Word Count Estimation: 26,258 Date of Issue: 2023-09-07 Date of Implementation: 2024-04-01 Older Standard (superseded by this standard): GB/T 28795-2012 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB/T 19258.2-2023: Ultraviolet radiation sources for germicidal purpose - Part 2: Cold cathode low pressure mercury vapour discharge lamp---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. ICS 29.140.30 CCSK71 National Standards of People's Republic of China Replace GB/T 28795-2012 UV radiation source for sterilization Part 2.Cold cathode low pressure mercury vapor discharge lamps Published on 2023-09-07 2024-04-01 Implementation State Administration for Market Regulation Released by the National Standardization Administration Committee Table of contentsPreface III Introduction IV 1 Scope 1 2 Normative reference documents 1 3 Terms and Definitions 1 4 Product classification, marking and model designation 4 5 Technical requirements 4 6 Test method 7 7 Inspection Rules 8 8 Logo, instructions, packaging, certificate, storage and transportation10 Appendix A (normative) Measurement methods of lamp and electrical parameters 11 Appendix B (normative) Measurement method of lamp starting characteristics 12 Appendix C (normative) Test method for ultraviolet radiation flux 14 Appendix D (normative) Measurement method of ultraviolet radiation illuminance15 Appendix E (normative) Test method for ozone production (static method) 16 Appendix F (normative) Life test method 19 Reference 20ForewordThis document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1.Structure and Drafting Rules of Standardization Documents" Drafting. This document is Part 2 of GB/T 19258 "Ultraviolet radiation sources for sterilization". GB/T 19258 has released the following parts. ---Part 1.Low pressure mercury vapor discharge lamp; ---Part 2.Cold cathode low pressure mercury vapor discharge lamps. This document replaces GB/T 28795-2012 "Cold Cathode Ultraviolet Germicidal Lamps". Compared with GB/T 28795-2012, except for structural adjustments In addition to editorial changes, the main technical changes are as follows. ---Added the definition of UV radiation illumination maintenance rate (see 3.18); ---The shape of the lamp has been changed, and the lead or lead terminal type cold cathode low-pressure mercury vapor discharge, which is more popular on the market, has been added Ultraviolet germicidal lamps, and stipulates its relevant technical requirements (see 4.1, Chapter 5, GB/T 28795-2012 4.1, 4.3, Chapter Chapter 5); ---Changed the rules for writing lamp models (see 4.2, 4.2 of GB/T 28795-2012); ---Added and modified the starting characteristics requirements and test methods of lamps (see 5.3 and Appendix B); ---Changed the regulations on the measurement distance of ultraviolet radiation illumination (see 6.6, 6.6 of GB/T 28795-2012); ---Changed the regulations on marking and packaging (see Chapter 8, Chapter 8 of GB/T 28795-2012); ---Changed the measurement method of lamp electrical parameters (see Appendix A, Appendix C of GB/T 28795-2012); ---An ultraviolet distributed radiometer is added, and the irradiance integration method is used to measure the ultraviolet radiation flux of the ultraviolet germicidal lamp under test (see attachment Record C); --- Added provisions for the cosine characteristics and nonlinear error requirements of UV probes, and changed the test conditions for measuring UV radiation illumination (see Appendix D, Appendix A of GB/T 28795-2012); ---Changed the test method for ozone production (see Appendix E, Appendix F of GB/T 28795-2012); ---Changed the test method for lamp life (see Appendix F, Appendix E of GB/T 28795-2012). Please note that some content in this document may be subject to patents. The publisher of this document assumes no responsibility for identifying patents. This document is proposed by China Light Industry Federation. This document is under the jurisdiction of the National Lighting Appliances Standardization Technical Committee (SAC/TC224). This document was drafted by. Ningbo Daxie Development Zone Youwei Optoelectronics Co., Ltd., Beijing Electric Light Source Research Institute Co., Ltd., Shenzhen Biosen Environmental Protection Technology Co., Ltd., Hangzhou Yuanfang Optoelectronics Information Co., Ltd., Shenzhen Zhongdian Lighting Co., Ltd., Changzhou Optoelectronics Zi Technology Co., Ltd., Changzhou Fuxing Electric Co., Ltd. The main drafters of this document. Wu Qiong, Zhang Bo, Zhao Peng, Huang Yan, Yang Party Committee, Wu Xiaosen, Liu Yingquan, Wang Shenhong, Hang Jun, Li Ximing, Hu Jinghui, Liu Zhongqiang. The previous versions of this document and the documents it replaces are as follows. ---First published as GB/T 28795-2012 in.2012; ---This is the first revision.IntroductionAfter pathogenic microorganisms absorb ultraviolet radiation energy with wavelengths between.200nm and 280nm, their genetic material (nucleic acid) undergoes mutations, leading to The disinfection method that causes cells to no longer divide and reproduce and achieve the purpose of inactivating pathogenic microorganisms is called ultraviolet disinfection. UV radiation source as UV killer The core component of sterilization products is used to achieve the purpose of sterilization and disinfection. GB/T 19258 "Ultraviolet radiation source for sterilization" aims to standardize the The safety requirements and performance requirements of ultraviolet radiation sources are planned to be composed of 5 parts. ---Part 1.Low-pressure mercury vapor discharge lamps. The purpose is to standardize the production of low-pressure mercury vapor discharge hot cathode ultraviolet germicidal lamps. Product classification, technical requirements, test methods, inspection rules and markings, packaging, transportation and storage. ---Part 2.Cold cathode low pressure mercury vapor discharge lamps. The purpose is to standardize low-pressure mercury vapor discharge cold cathode ultraviolet sterilization Product classification, technical requirements, test methods, inspection rules and markings, packaging, transportation and storage of lamps. ---Part 3.UV excimer lamp. The purpose is to standardize the product classification and technology of 222nm ultraviolet KrCl excimer lamps Requirements, test methods, inspection rules and markings, packaging, transportation and storage. ---Part 4.UV germicidal lamp based on photocatalysis. The purpose is to standardize products that utilize ultraviolet radiation sources for photocatalytic sterilization Classification, technical requirements, test methods, inspection rules and markings, packaging, transportation and storage. ---Part 5.UV LED radiation source for sterilization. The purpose is to standardize the product classification and technology of UV LED radiation sources for sterilization Requirements, test methods, inspection rules and markings, packaging, transportation and storage. UV radiation source for sterilization Part 2.Cold cathode low pressure mercury vapor discharge lamps1 ScopeThis document specifies the ultraviolet radiation source cold cathode low pressure mercury vapor discharge lamp for sterilization, that is, cold cathode ultraviolet germicidal lamp (hereinafter referred to as "Lamp") product classification, technical requirements, test methods, inspection rules and markings, packaging, transportation and storage. This document applies to ozone or ozone-free products produced using quartz glass or other ultraviolet-transparent glass. The peak wavelength of ultraviolet radiation is 253.7nm double-ended, single-ended, self-ballasted, wire or wire terminal lamps.2 Normative reference documentsThe contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, the dated quotations For undated referenced documents, only the version corresponding to that date applies to this document; for undated referenced documents, the latest version (including all amendments) applies to this document. GB/T 2828.1-2012 Enumeration sampling inspection procedures Part 1.Batch-by-batch inspection sampling retrieved by acceptance quality limit (AQL) plan GB/T 2829-2002 Periodic inspection counting sampling procedures and tables (applicable to inspection of process stability) GB/T 2900.65 Electrical terminology lighting GB 16843 Safety requirements for single-ended fluorescent lamps GB 16844 Safety requirements for self-ballasted lamps for general lighting GB/T 17263 Performance requirements for self-ballasted fluorescent lamps for general lighting GB 18774 Safety requirements for double-ended fluorescent lamps GB/T 19149 General requirements and requirements for tubular discharge lamp transformers (neon lamp transformers) with no-load output voltage exceeding 1000V security requirements GB/T 19258.1-2022 Ultraviolet radiation sources for sterilization Part 1.Low-pressure mercury vapor discharge lamps JJG879-2015 UV radiation meter HJ590-2010 Determination of ambient air ozone by ultraviolet photometry3 Terms and definitionsThe terms and definitions defined in GB/T 2900.65 and the following apply to this document. 3.1 A cold cathode glow discharge low-pressure mercury vapor discharge lamp using quartz glass or other transparent purple glass. The discharge produces a wavelength of Ultraviolet radiation mainly at 253.7nm. Note. Its ultraviolet radiation can kill bacteria and viruses. Effective sterilization and disinfection require a certain ultraviolet dose. The ultraviolet dose refers to the amount of radiation received per unit area. of ultraviolet energy. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 19258.2-2023_English be delivered?Answer: Upon your order, we will start to translate GB/T 19258.2-2023_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 19258.2-2023_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 19258.2-2023_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |