GB/T 18858.2-2012 English PDFUS$3994.00 · In stock
Delivery: <= 10 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 18858.2-2012: Low-voltage switchgear and controlgear -- Controller-device interfaces (CDIs) -- Part 2: Actuator sensor interface (AS-i) Status: Valid GB/T 18858.2: Historical versions
Basic dataStandard ID: GB/T 18858.2-2012 (GB/T18858.2-2012)Description (Translated English): Low-voltage switchgear and controlgear -- Controller-device interfaces (CDIs) -- Part 2: Actuator sensor interface (AS-i) Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: K30 Classification of International Standard: 29.130.01 Word Count Estimation: 200,216 Older Standard (superseded by this standard): GB/T 18858.2-2002 Quoted Standard: GB/T 2423.10-2008; GB/T 2423.5-1995; GB/T 3956-2008; GB 5226.1-2008; GB 14048.6-2008; GB/T 14048.7-2006; GB/T 12668.2-2002; GB/T 14048.10-2008; GB/T 17045-2008; GB/T 17626.2-2006; GB/T 17626.3-2006; GB/T 17626.4-2008; GB/T 18858.1-2012; GB/T 21207-2007; G Adopted Standard: IEC 62026-2-2008, IDT Regulation (derived from): National Standards Bulletin No. 28 of 2012 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard provides a single control devices and switching elements a method of communication between, and having a predetermined communication interface components to establish interoperability systems. Complete system called "Actuator Sensor Interfac GB/T 18858.2-2012: Low-voltage switchgear and controlgear -- Controller-device interfaces (CDIs) -- Part 2: Actuator sensor interface (AS-i)---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Low-voltage switchgear and controlgear Controller-device interfaces (CDIs) Part 2. Actuator sensor interface (AS-i) ICS 29.130.01 K30 National Standards of People's Republic of China Replacing GB/T 18858.2-2002 Low-voltage switchgear and control equipment Controller - Device Interface (CDI) Part 2. Actuator Sensor Interface (AS-i) Low-Voltageswitchgearandcontrolgear-Controler-deviceinterfaces (CDI) - Part 2. Actuatorsensorinterface (AS-i) (IEC 62026-2.2008, IDT) Issued on. 2012-11-05 2013-02-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Table of ContentsIntroduction Ⅲ Introduction Ⅳ 1 Scope 1 2 Normative references 1 3 Terms and definitions, symbols and abbreviations 2 4 Category 7 5 Features 9 46 6 Product information 7 work, installation and transport conditions 48 8 structure and performance requirements 48 9 Test 70 Appendix A (normative) Description Slave 112 Appendix B (normative) 189 master DescriptionForewordGB/T 18858 "Low-voltage switchgear and control equipment Controller - Device Interface (CDI)" is divided into three parts. --- Part 1. General; --- Part 2. Actuator Sensor Interface (AS-i); Part --- Section 3. DeviceNet. This section GB/T 18858 Part 2. This section drafted in accordance with GB/T 1.1-2009 given rules. This section identical with IEC 62026-2.2008 "low-voltage switchgear and control - Controller - device interfaces - Part 2. Executive Actuator sensor interface (AS-i) "(in English). This Part replaces GB/T 18858.2-2002 "Low-voltage switchgear and control equipment controller - device interfaces - Part 2. Executive Actuator sensor interface (AS-i) ". This section compared with the GB/T 18858.2-2002, following major technical differences. --- Introduction of secondary addresses, the number increased from the station from 31-62; --- Introduction of AS-i safety system. Consistency correspondence between this part of international documents and normative references of our files are as follows. --- GB 14048.1 low-voltage switchgear and control equipment Part 1. General (IEC 60947-1.2011, MOD) --- GB 14048.4-2010 Low-voltage switchgear and control equipment - Part 4-1. Contactors and motor starters electromechanical Contactors and motor starters (including motor protection) (IEC 60947-4-1.2009, MOD) This part is proposed by the China Electrical Equipment Industrial Association. The low-voltage electrical part by the National Standardization Technical Committee (SAC/TC189) centralized. This section is responsible for drafting unit. Shanghai Electric Apparatus Research Institute, Shanghai Electric Technology Co., Ltd. Electric Division. Participated in the drafting of this section. Shanghai Electric Co., Ltd. People's Electric Factory, France and Thailand Electric (Jiangsu) Co., Ltd., Shanghai Electric Detecting device, the China Quality Certification Center, Zhejiang Tengen Electric Co., Ltd., Shanghai People Enterprise Group Electric Co., Ltd. Wenzhou. The main drafters of this section. Xue Ji, Ji Yu Hui, Zhang Jian soldiers. The drafters of some of the participants. Feng Jun, Ding Gaofeng, Nguyen Gyeongju, Zhang Ying, Jiaying Wei, Li Peng, Jin Ling full. This part of the standard replaces the previous editions are. --- GB/T 18858.2-2002.IntroductionDescribed in this section of the input and output relative to the master station concerned, if the user, and vice versa. Part 1 to 8 for the general requirements of Chapter 9 test. Specifically asked to describe the various actuators, sensors, and so on in the relevant master Stated in the Appendix. Low-voltage switchgear and control equipment Controller - Device Interface (CDI) Part 2. Actuator Sensor Interface (AS-i)1 ScopeGB/T 18858 provisions of this section, a single communication method control device and switching between the elements, and having a predetermined pass Member communications interface to establish interoperability systems. Complete system called "Actuator Sensor Interface (AS-i)". This section describes the connection switching element, such as GB 14048 within the range of low-voltage switchgear and control equipment, control equipment and party law. This method can also be used to connect electrical and other components. Within the scope of this standard to describe the input and output I/O, its meaning is in terms of the main station for the application of the meaning is the opposite. The purpose of this section is to control provisions between the circuit devices and switching elements of the following requirements. --- Transmission system requirements, interface requirements and the station master and electromechanical devices from; --- Within the scope of this section, any network in different appliances complete interoperability requirements; --- Comply within the network described in this section device interchangeability requirements; --- Slaves, normal operating conditions and electrical equipment and master; --- Structural and performance requirements; --- Consistency verification.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 2423.10-2008 Environmental testing for electric and electronic products Part 2. Test methods Test Fc. Vibration (sinusoidal) (IEC 60068-2-6.1995, IDT) GB/T 2423.5-1995 Environmental testing for electric and electronic products Part 2. Test methods Test Ea and guidance. Shock (Idt IEC 60068-2-27. 1987) GB/T 3956-2008 conductor cable (IEC 60228.2004, IDT) GB 5226.1-2008 Safety of machinery - Electrical machinery and electrical equipment - Part 1. General requirements (IEC 60204-1.2005, IDT) GB 14048.6-2008 Low-voltage switchgear Part 4-2. Contactors and motor starters - AC semiconductor motor control System and starters (including soft starters) (IEC 60947-4-2.2002, IDT) GB/T 14048.7-2006 Low-voltage switchgear and control equipment - Part 7-1. Ancillary Terminal blocks for copper conductors (IEC 60947-7-1.2002, MOD) GB/T 12668.2-2002 speed electrical power drive systems - Part 2. General requirements for low voltage adjustable frequency ac power drive systems Amount A predetermined set value (IEC 61800-2.1998, IDT) GB/T 14048.10-2008 voltage switchgear and control equipment Part 5-2. Control circuit devices and switching elements connected Near switches (IEC 60947-5-2.2004, IDT) GB/T 17045-2008 General Protection against electric shock devices and equipment (IEC 61140.2001, IDT) ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 18858.2-2012_English be delivered?Answer: Upon your order, we will start to translate GB/T 18858.2-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 6 ~ 10 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 18858.2-2012_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 18858.2-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 18858.2-2012?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 18858.2-2012 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |