GB/T 18477.1-2007 English PDFUS$449.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 18477.1-2007: The underground drainage structural pipe system with a hard polyvinyl chloride (PVC-U) -- Part 1: double wall corrugated pipes Status: Valid GB/T 18477.1: Historical versions
Basic dataStandard ID: GB/T 18477.1-2007 (GB/T18477.1-2007)Description (Translated English): The underground drainage structural pipe system with a hard polyvinyl chloride (PVC-U) -- Part 1: double wall corrugated pipes Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: G33 Classification of International Standard: 83.140.30 Word Count Estimation: 17,122 Date of Issue: 2007-12-05 Date of Implementation: 2008-09-01 Older Standard (superseded by this standard): GB/T 18477-2001 Quoted Standard: GB/T 1033-1986; GB/T 2828.1-2003; GB/T 2918-1998; GB/T 6111-2003; GB/T 8806; GB/T 9647-2003; GB/T 14152-2001; GB/T 18042-2000; GB/T 19278-2003; ISO 13968-1997 Regulation (derived from): China Announcement of Newly Approved National Standards No. 13 of 2007 (No. 113 overall) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the order polyvinyl chloride resin as the main raw material, extrusion underground drainage PVC double wall corrugated pipe materials, classification, structure and pipe connections, technical requirements, test methods, inspection rules and signs, transportation and storage. This section applies to municipal underground non-pressure drainage, outside the building drainage, irrigation and drainage pipes can also be used for communication cable threading bushing. Taking into account the material chemical resistance and temperature resistance can be used for non-pressure underground after the industrial sewage pipes. GB/T 18477.1-2007: The underground drainage structural pipe system with a hard polyvinyl chloride (PVC-U) -- Part 1: double wall corrugated pipes---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. The underground drainage structural pipe system with a hard polyvinyl chloride (PVC-U) - Part 1. double wall corrugated pipes ICS 83.140.30 G33 National Standards of People's Republic of China Replacing GB/T 18477-2001 Underground drainage Hard polyvinyl chloride (P Vp CU) structure wall pipeline system Part 1. double wall corrugated pipes Posted 2007-12-05 2008-09-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordGB/T 18477 "buried drainage with a hard polyvinyl chloride (PVC-U) structure wall pipeline system" is divided into three parts. --- Part 1. double wall corrugated pipe; --- Zi Part 2. Reinforced Pipe (ready to develop); --- Part 3. Axial hollow double wall pipes (preparation formulation). This section GB/T Part of 118,477. This Part replaces GB/T 18477-2001 "buried drainage with a hard polyvinyl chloride (PVC-U) double wall corrugated pipes." This standard revision With reference to the international standard ISO /DIS21138-1.2006 "non-pressure underground drainage and sewerage - Thermoplastics piping systems for rigid PVC (PVC-U), polypropylene (PP) and polyethylene (PE) structure wall pipe systems - Part 1. pipes, fittings and material requirements and system performance is Seeking "and ISO /DIS21138-3.2006" non-pressure underground drainage and sewerage - Thermoplastics piping systems for rigid polyvinyl chloride (PVC-U), poly Propylene (PP) and polyethylene (PE) structure wall pipe systems - Part 3. Type B is not smooth outer pipe and tube "on the hard polyvinyl chloride It requires structural wall pipe section. This section compared with the GB/T 18477-2001 main changes are. --- Added "definitions, symbols" chapter (see Chapter 3); --- Increasing the size of the inner diameter of the series (see 7.3); --- Increasing the wall thickness of the laminate, inner layer thickness requirements (see 7.3); --- Increasing the density requirements (see 7.4); --- Increasing system suitability test (7.5); --- Increased in Appendices A and B. Please note that some of the content of this section may involve patents. This part of the release mechanism should not bear the responsibility to identify these patents. Appendix A of this section is an informative annex, Annex B normative appendix. This part is proposed by the China National Light Industry Council. This part of the National Plastics Standardization Technical Committee (SAC/TC48) centralized. This section drafted by. AD Plastic Industry Group, Zhejiang Science and Technology Co., Ltd. pipeline in the fiscal, Liansu Technology Industrial Co. Ltd., Fujian Asia-built New Material Technology Co., Ltd., Anhui-high-tech management of the Company, Chongqing and plastic LAB Electric Co., Ltd., Hangzhou Arrival Plastic Co., Ltd., Jiangsu Province Product Quality Supervision and Inspection Center. The main drafters of this section. Huang Jian, Ding Liangyu, the whole forest little, Weizuo You, Zhang Wenli, Wuxiao Fen, cycle, Zhu Yuhong. Underground drainage Hard polyvinyl chloride (P Vp CU) structure wall pipeline system Part 1. double wall corrugated pipes1 ScopeThis section GB/T 18477 specifies the polyvinyl chloride resin as the main raw material, extrusion underground drainage with a hard polyvinyl chloride Double wall corrugated pipes (hereinafter referred to as "pipe") material classification, structure and pipe connections, technical requirements, test methods, inspection rules and signs, Transportation and storage. This section applies to municipal non-pressure underground drainage, outside the building drainage, irrigation and drainage pipe can also be used for communication cable threading cannula. Taking into account the material temperature resistance, chemical resistance and can be used for non-pressure underground industrial sewage pipes.2 Normative referencesThe following documents contain provisions which, through reference GB/T 18477 in this section, constitute provisions of this part. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section. GB/T 1033-1986 plastic density and relative density test method GB/T 2828.1-2003 Sampling procedures for inspection - Part 1. by acceptance quality limit (AQL) retrieval batch test sample Programme (ISO 2859-1.1999, IDT) GB/T 2918-1998 standard plastic sample conditioning and environmental tests (idt ISO 291.1997) GB/T 6111-2003 Test method for conveying fluid pressure within the thermoplastic pipe (ISO 1167.1996, IDT) GB/T 8806 plastic pipe size measurement method (GB/T 8806-1988, eqv ISO 3126. 1974) GB/T 9647-2003 thermoplastic pipe ring stiffness determination (ISO 9969.1994, IDT) GB/T 14152-2001 thermoplastic pipe resistance to external impact performance test clock method (eqv ISO 3127.1994) GB/T 18042-2000 Test method for thermoplastic plastic pipe creep ratio (eqv ISO 9967.1994) GB/T 19278-2003 Thermoplastics pipes, fittings and valves General terms and their definitions ISO 13968.1997 Plastics pipes and delivery systems Thermoplastics pipes - Determination of ring flexibility 3 Definitions, symbols GB/T 19278-2003 determined and the following definitions and symbols apply to this section. 3.1 Definitions 3.1.1 Nominal size DN It represents a number of pipe sizes in millimeters (mm) in units of approximate dimensions. 3.1.2 Nominal size DN/OD Associated with the outer diameter of the nominal size in millimeters (mm). 3.1.3 Nominal size DN/ID And the inner diameter of the relevant nominal dimensions in millimeters (mm). ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 18477.1-2007_English be delivered?Answer: Upon your order, we will start to translate GB/T 18477.1-2007_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 18477.1-2007_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 18477.1-2007_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 18477.1-2007?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 18477.1-2007 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |