GB/T 17216-2025 English PDF

GB/T 17216-2025_English: PDF (GB/T17216-2025)
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 17216-2025459 Add to Cart 4 days Hygienic requirement for peacetime utilization of civil air defence works Valid
GB/T 17216-2012209 Add to Cart 3 days Hygienic requirements for peacetime utilization of civil air defence works Valid
GB/T 17216-1998359 Add to Cart 3 days Hygienic standard for peacetime utilization of civil air defence works Obsolete

BASIC DATA
Standard ID GB/T 17216-2025 (GB/T17216-2025)
Description (Translated English) Hygienic requirement for peacetime utilization of civil air defence works
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard C51
Classification of International Standard 13.100
Word Count Estimation 22,266
Date of Issue 2025-04-25
Date of Implementation 2025-11-01
Older Standard (superseded by this standard) GB/T 17216-2012
Issuing agency(ies) State Administration for Market Regulation, National Standardization Administration


GB/T 17216-2025.Environmental sanitation requirements for civil air defense projects in peacetime ICS 13.100 CCSC51 National Standard of the People's Republic of China Replaces GB/T 17216-2012 Environmental sanitation requirements for civil air defense projects in peacetime Released on 2025-04-25 2025-11-01 Implementation State Administration for Market Regulation The National Standardization Administration issued Table of contents Preface III 1 Range 1 2 Normative references 1 3 Terms and Definitions 1 4 Hygiene requirements 2 5 Monitoring and testing methods 7 Appendix A (Normative) Indoor fresh air volume monitoring test method 9 Reference 14 Preface This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1.Structure and drafting rules for standardization documents" Drafting. This document replaces GB/T 17216-2012 "Environmental sanitation requirements for civil air defense projects in peacetime" and is consistent with GB/T 17216-2012. In addition to structural adjustments and editorial changes, the main technical changes are as follows. --- Changed the scope of application (see Chapter 1, Chapter 1 of the.2012 edition); --- Changed the terms related to "civil air defense projects" (see 3.1, 3.1 of the.2012 edition); --- Added the term "radon concentration reference level" (see 3.2); --- Changed the general requirements and environmental health index requirements (see Chapter 4, Chapter 4 and Chapter 5 of the.2012 edition); --- Changed the monitoring and inspection methods (see Chapter 5, Chapter 6 of the.2012 edition); --- Added “Indoor fresh air volume monitoring and test method” (see Appendix A). Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents. This document is proposed and coordinated by the National Center for Disease Control and Prevention. This document was drafted by. Institute of Environmental and Health-related Product Safety, Chinese Center for Disease Control and Prevention, Radiation Institute of Protection and Nuclear Safety Medicine, Tsinghua University, Institute of Nutrition and Health, Chinese Center for Disease Control and Prevention, Shanghai Jianke Environmental Technology Co., Ltd., National Defense Engineering Research Institute of the Academy of Military Sciences, South China University of Technology. The main drafters of this document are. Wang Qiang, Zhang Yinping, Li Jingguang, Lü Fang, Zhao Yuezhe, Sun Zongke, Wu Yunyun, Wei Jingya, Zheng Ping and Xu Ning. The previous versions of this document and the documents it replaces are as follows. ---First published as GB/T 17216-1998 in.1998 and first revised in.2012; ---This is the second revision. Environmental sanitation requirements for civil air defense projects in peacetime 1 Scope This document stipulates the environmental sanitation requirements for the peacetime use of civil air defense projects. This document is applicable to accommodation, business (including shopping malls/supermarkets, catering services, etc.) and entertainment (including performances, singing and dancing entertainment, etc.) For civil air defense projects in places such as swimming pools, and other places for normal use, refer to the relevant public place hygiene standards of our country. 2 Normative references The contents of the following documents constitute essential clauses of this document through normative references in this document. For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to This document. GB/T 16129 Standard method for the examination of formaldehyde in the atmosphere of residential areas - Spectrophotometric method GB/T 18204.1 Public place hygiene inspection methods Part 1.Physical factors GB/T 18204.2 Public place hygiene inspection methods Part 2.Chemical pollutants GB/T 18204.3 Public places hygiene inspection methods Part 3.Air microorganisms GB/T 18883 Indoor Air Quality Standard GB 37487 Public Place Hygiene Management Standard GB 37488 Hygiene indicators and limit requirements for public places GB 37489.1 Sanitary code for design of public places Part 1.General principles GB 50038 Design specification for civil air defense basements GB 50118 Code for design of sound insulation for civil buildings GB 50225 Code for Design of Civil Air Defense Engineering GB/T 50355 Standard for indoor vibration limits and measurement methods for residential buildings GBZ /T 182 Specification for the measurement of indoor radon and its decay products HJ583 Determination of benzene series in ambient air by solid adsorption/thermal desorption-gas chromatography HJ584 Determination of benzene series in ambient air - activated carbon adsorption/carbon disulfide desorption-gas chromatography HJ683 Determination of aldehyde and ketone compounds in ambient air by high performance liquid chromatography HJ1212 Measurement method of radon in ambient air 3 Terms and definitions The following terms and definitions apply to this document. 3.1 Civil air defense works A protective building built to ensure the needs of civil air defense command, communication, shelter, etc. Note. Also known as civil air defense works. [Source. GB 50098-2009, 2.0.1, modified] ......


GB/T 17216-2012 ICS13.100 C51 National Standards of People's Republic of China Replacing GB/T 17216-1998 Air defense projects usually use environmental health requirements Issued on. 2012-10-01 2012-06-29 implementation People's Republic of China Ministry of Health Standardization Administration of China released Foreword This standard rule according to GB/T 1.1-2009 given draft. This standard replaces GB/T 17216-1998 "air defense projects usually use environmental health standards." This standard compared with GB/T 17216-1998, major technical changes are as follows. --- According to GB/T 1.1-2009 "Standardization Guide Part 1. Structure and rules are written standard" structural adjustment; --- Modify the scope of the standard; --- Increasing the normative references; --- Increased the fresh air requirements, increased health requirements underground swimming places; --- Increase the fresh air monitoring methods, the standard method of testing methods of the total number of bacteria and air defense projects radon concentration measured; --- Remove the limit for the amount of air oxygen; --- Remove the air oxygen consumption test method. This standard is proposed and administered by the People's Republic of China Ministry of Health. This standard was drafted. Chinese Center for Disease Control Environmental Health and Related Product Safety. The main drafters of this standard. Wang Qiang, Xu group, Xu Chunyu Wang Qin. This standard replaces the standards previously issued as follows. --- GB/T 17216-1998. Air defense projects usually use environmental health requirements 1 Scope This standard specifies requirements for the environmental health of the national air defense projects usually use. This standard applies to the usual function of hostels (hostels, hotels, etc.), shopping malls, discos (including recreation hall, music cafe, function rooms, etc.), Movies Theater (including concert halls, video halls, halls, etc.), restaurants, hospitals and swimming pool and other Class 7 air defense projects, civil air defense projects for other purposes of reference phase Related public health standards. 2 Normative references The following documents for the application of this document is essential. For dated references, only the dated edition applies to this article Member. For undated references, the latest edition (including any amendments) applies to this document. GB 9663 hotel industry hygiene standards GB 9664 cultural entertainment hygiene standards GB 9667 standard for swimming place GB 9670 shopping malls (stores), bookshops health standards GB 9671 hospital waiting room hygiene standards GB/T 14582 standard measurement methods of radon in ambient air GB/T 16147 radon concentration measurement scintillation vials GB 16153 restaurant (restaurant) health standards GB/T 18204.1 air in public places Determination of aerobic bacterial microbial test methods GB/T 18204.13 public places, air temperature measurement method GB/T 18204.14 public places air humidity measurement method GB/T 18204.15 wind speed measuring method in public places GB/T 18204.18 indoor public places Determination of Fresh Air GB/T 18204.21 illuminance measurement method in public places GB/T 18204.22 noise measurement method in public places GB/T 18204.23 public places Determination of carbon monoxide in air Determination of GB/T 18204.24 of carbon dioxide in the air in public places GB/T 18204.26 public places, determination of formaldehyde in air GB 50038 civil air defense basement design specifications GB 50225 People's air defense engineering design specifications 3 Terms and Definitions The following terms and definitions apply to this document. 3.1 Air defense projects civilairdefenceworks Also known as air defense fortifications for the protection of civil air defense command, communications, shelter and other needs of the construction of protective buildings. ......