Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 16895.23-2020 English PDF

US$794.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 16895.23-2020: Low-voltage electrical installations - Part 6: Verification
Status: Valid

GB/T 16895.23: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 16895.23-2020794 Add to Cart 5 days Low-voltage electrical installations - Part 6: Verification Valid
GB/T 16895.23-2012RFQ ASK 3 days Low-voltage electrical installations -- Part 6: Verification Obsolete
GB/T 16895.23-2005759 Add to Cart 3 days The building electrical 6-16: Verification -- Initial verification Obsolete

Similar standards

GB/T 16895.3   GB/T 16895.19   GB 17945   GB/T 16895.24   GB/T 16895.25   GB/T 16895.22   

Basic data

Standard ID: GB/T 16895.23-2020 (GB/T16895.23-2020)
Description (Translated English): Low-voltage electrical installations - Part 6: Verification
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: Q77
Classification of International Standard: 91.140.50
Word Count Estimation: 42,496
Date of Issue: 2020-12-14
Date of Implementation: 2021-07-01
Older Standard (superseded by this standard): GB/T 16895.23-2012
Regulation (derived from): National Standard Announcement No. 28 of 2020
Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration

GB/T 16895.23-2020: Low-voltage electrical installations - Part 6: Verification

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Low-voltage electrical installations Part 6: Inspection) ICS 91:140:50 Q77 National Standards of People's Republic of China Replace GB/T 16895:23-2012 Low-voltage electrical installations Part 6: Inspection (IEC 60364-6:2016, IDT) 2020-12-14 release 2021-07-01 implementation State Administration for Market Regulation Issued by the National Standardization Management Committee

Table of contents

Preface Ⅲ 6:1 Scope 1 6:2 Normative references 1 6:3 Terms and definitions 2 6:4 Initial inspection 2 6:4:1 General 2 6:4:2 Inspection 3 6:4:3 Test 3 6:4:4 Initial inspection report 8 6:5 Periodic inspection 8 6:5:1 General 8 6:5:2 Periodic inspection interval 9 6:5:3 Periodic inspection report 9

Appendix A

(Informative appendix) Resistance estimate that may be obtained during the continuity test 10

Appendix B

(Informative appendix) Method of measuring insulation resistance/impedance of floor and wall to ground or protective conductor 11 B:1 General 11 B:2 Method of measuring the impedance of floors and walls using AC voltage 11 B:3 Test electrode 1 11 B:4 Test electrode 2 12

Appendix C

(Informative appendix) Measurement of ground electrode resistance---Method C1, Method C2 and Method C3 13 C:1 Method C1---Earth electrode resistance measurement using earth electrode test equipment 13 C:2 Method C2---Use a fault loop impedance tester to measure ground electrode resistance 14 C:3 Method C3---Using a current clamp to measure ground electrode resistance 15

Appendix D

(Informative appendix) 6:4 Application guidelines for initial inspection 17

Appendix E

(Informative appendix) Report template 19

Appendix F

(Informative appendix) Electrical installation inspection template 26 F:1 List of check items for initial inspection of electrical installations 26 F:2 List of inspection items for existing electrical installations 29

Appendix G

(Informative appendix) Circuit details and test result list template 34 Reference 35 Figure B:1 Test electrode 1 12 Figure B:2 Test electrode 2 12 Figure C:1 Measuring ground electrode resistance 13 Figure C:2 Use the fault loop impedance test equipment to measure the ground electrode resistance 15 60364-6:2016 Figure C:3 Use current clamp to measure ground electrode resistance 16 Table 6:1 Minimum insulation resistance 4 Table A:1 According to the nominal cross-sectional area S to 30 The specific resistance value R of copper conductor at ℃ can be used to estimate conductor resistance 10 Table E:1 Electrical installation inspection report (new or modified installation) 19 Table E:2 Status report of electrical installations (existing installations) 21 Table G:1 Circuit details and test result list template 34 60364-6:2016

Foreword

GB/T 16895 "Low-Voltage Electrical Installations" is divided into 5 parts, and each part is divided into multiple sub-parts: ---Part 1: Evaluation and definition of basic principles, general characteristics; ---Part 4: Security Protection; ---Part 5: Selection and installation of electrical equipment; ---Part 6: Inspection; ---Part 7: Requirements for special devices or places: This part is GB/T Part 6 of 16895: This part is in accordance with GB/T Drafting of the rules given in 1:1-2009: This part replaces GB/T 16895:23-2012 "Low-Voltage Electrical Installation Part 6: Inspection", and GB/T 16895:23-2012 In comparison, the main technical changes are as follows: ---Modified normative reference documents (see 6:2,:2012 edition 6:2); ---Added 3 items of preliminary inspection regulations (see 6:4:2:3); ---Modified the test sequence (see 6:4:3:1, 61:3:1 of the:2012 edition); ---Added more details in the general provisions of periodic inspection (see 6:5:1); --- Added Table A:1 (see Appendix A) for the specific resistance value of copper conductors; --- Deleted the example of the simplified diagram of the original Appendix D on the voltage drop evaluation (see Appendix D of the:2012 edition); --- Deleted the original Appendix E recommendations for electrical equipment that have been reused in electrical installations (see Appendix E of the:2012 edition): The translation method used in this part is equivalent to the IEC 60364-6:2016 "Low-Voltage Electrical Installation Part 6: Inspection": The Chinese documents that have a consistent correspondence with the international documents cited in this section are as follows: ---GB 3836:16-2017 Electrical equipment for explosive gas atmosphere Part 16: Inspection and maintenance of electrical installations (coal mine Except) (IEC 60079-17:2007, IDT); ---GB/T 16895 (all parts) Low-voltage electrical installations [IEC 60364 (all parts), IDT); ---GB/T 16895:3-2017 Low-voltage electrical installations Part 5-54: Selection and installation of electrical equipment Grounding configuration and protection Protective conductor (IEC 60364-5-54:2011, IDT); ---GB/T 18216 (all parts) Exchange 1 000 V and DC 1 500 Electrical safety protection measures for low-voltage power distribution systems below V Testing, measuring or monitoring equipment [IEC 61557 (all parts), IDT); This section has made the following editorial changes: ---Corrected IEC 60364-6:2016/COR1:2017 content; ---IEC In 60364-6:2016 6:5:1:2, g) and c) are repeated, h) and d) are repeated, and g) and h) are deleted in this section; ---IEC 60364-6: The 61:4:2 cited in Appendix E of:2016, amended 6:4 according to the content of the main text; 62:1 cited in Table E:2: 4 and 62:1:5 are merged into 6:5; ---IEC Appendix H of 60364-6:2016 is a note applied in other countries, which has nothing to do with my country, and is deleted in this section; ---IEC has been deleted 60364-6:2016 Note 6:4:1:6, 6:5:1:5 Note and 6:5:3:6 Note 2: This part is organized by the National Standardization Technical Committee for Building Electrical Installations (SAC/TC 205) Propose and manage: Drafting organizations of this section: CMC China Design & Research Institute Co:, Ltd:, Unitech (China) Co:, Ltd:, Suzhou Electrical Appliance Science Research Institute Co:, Ltd:, Beijing Xingdian International Engineering Management Co:, Ltd:, Xiamen Jiatli Technology Co:, Ltd:, Legrand low-voltage electrical appliances (no 60364-6:2016 Tin) Co:, Ltd:, Siemens (China) Co:, Ltd:, Schneider Electric (China) Co:, Ltd: The main drafters of this section: Ren Changning, Huang Baosheng, Hong Shaojun, Hong Shaolin, Mao Xiang, Hu Delin, Hu Jianping, Liu Yang, Hu Hongyu, Tang Ying, Zheng Haifeng: The previous versions of the standards replaced by this part are as follows: ---GB/T 16895:23-2005; GB/T 16895:23-2012: 60364-6:2016 Low-voltage electrical installations Part 6: Inspection 6:1 Scope GB/T This part of 16895 gives the initial inspection and periodic inspection requirements for electrical installations: Through inspection and testing, Chapter 6:4 gives the requirements for the initial inspection of electrical installations, as far as possible to determine GB/T 16895 Whether the relevant requirements of other parts of the company have been met, and put forward the requirements for the initial inspection result report: Upon completion of new installations or existing installations After the restructuring and expansion are completed, the initial inspection will be carried out: Chapter 6:5 gives periodic inspections of electrical installations to ascertain as far as possible whether the installation and all its supporting equipment meet the requirements for use: And the requirements for periodic inspection results reporting: 6:2 Normative references The following documents are indispensable for the application of this document: For dated reference documents, only the dated version applies to this article Pieces: For undated references, the latest version (including all amendments) applies to this document: GB/T 16895:2-2017 Low-voltage electrical installations Part 4-42: Safety protection Thermal effect protection (IEC 60364-4-42: 2010, IDT) GB/T 16895:6-2014 Low-voltage electrical installations Part 5-52: Selection of electrical equipment and installation wiring system (IEC 60364-5-52:2009, IDT) GB/T 16895:10-2010 Low-voltage electrical installations Part 4-44: Safety protection Voltage disturbance and electromagnetic disturbance protection (IEC 60364-4-44:2007,IDT) GB/T 16895:18-2010 Electrical installations of buildings Part 5-51: General rules for the selection and installation of electrical equipment (IEC 60364-5-51:2005, IDT) GB/T 16895:21-2011 Low-voltage electrical installations Part 4-41: Safety protection Electric shock protection (IEC 60364-4-41: 2005, IDT) GB/T 16895:22-2004 Building Electrical Installations Part 5-53: Selection and Installation of Electrical Equipment-Isolation, Switching and Control Section 534: Overvoltage Protection Equipment (IEC 60364-5-53:2001/AMD1:2002, IDT) IEC 60079-17 Explosive atmosphere Part 17: Inspection and maintenance of electrical installations (Explosive atmospheres-Part 17: Electrical instalations inspection and maintenance) IEC 60364 (all parts) Low-voltage electrical equipment (Low-voltage electrical instalations) IEC 60364-4-42:2010/ AMD1:2014 Low-Voltage Electrical Installation Part 4-42: Safety Protection Thermal Effect Protection (Low- voltage electrical instalations-Part 4-42: Protection for safety-Protection against thermal effects) IEC 60364-4-44:2007/AMD1:2015 Low-voltage electrical installations Part 4-44: Safety protection against voltage disturbances and electromagnetic disturbances Interference protection (Low-voltage electrical instalations-Part 4-44: Protection for safety-Protection against volt- age disturbances and electromagnetic disturbances) IEC 60364-5-53:2001/AMD2:2015 Electrical installations of buildings Part 5-53: Selection and installation of electrical equipment Section 534: Switchgear and Control Equipment (Electrical instalations of buildings-Part 5-53: Selection and erection of electrical equipment-Isolation, switching and control-Section 534: Devices for protection against ov- ervoltages) IEC 60364-5-54 Low-voltage electrical installations Part 5-54: Selection and installation of electrical equipment, grounding arrangements and protective conductors 60364-6:2016
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 16895.23-2020_English be delivered?

Answer: Upon your order, we will start to translate GB/T 16895.23-2020_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 16895.23-2020_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 16895.23-2020_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 16895.23-2020?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 16895.23-2020 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.