| GB/T 11297.12-2012 English PDFUS$139.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 11297.12-2012: Test method for extinction ratio of optical crystal Status: Valid GB/T 11297.12: Historical versions
 Basic dataStandard ID: GB/T 11297.12-2012 (GB/T11297.12-2012)Description (Translated English): Test method for extinction ratio of optical crystal Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: L21 Classification of International Standard: 31.140 Word Count Estimation: 6,613 Older Standard (superseded by this standard): GB/T 11297.12-1989 Quoted Standard: GB/T 11293-1989 Regulation (derived from): National Standards Bulletin No. 41 of 2012 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the use of a wavelength of 632. 8 nm light waves along the optical axis of uniaxial optical crystal extinction ratio measurement method. This section applies to a wavelength of 632. 8 nm, 1 064 nm, 830 nm, 514 nm, 488 nm, 458 nm an GB/T 11297.12-2012: Test method for extinction ratio of optical crystal---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.ICS31.140 L21 National Standards of People's Republic of China Replacing GB/T 11297.12-1989 Measurement of optical crystal extinction ratio Issued on. 2013-06-01 2012-12-31 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordRules in this section in accordance with GB/T 1.1-2009 given draft. This Part replaces GB/T 11297.12-1989 measuring party "electro-optic crystal of lithium niobate, potassium dihydrogen phosphate and potassium phosphate dihydrate extinction ratio of deuterium law". This section compared with GB/T 11297.12-1989, have the following main changes. --- The original part of the name has been modified. Original Part Name "electro-optic crystal of lithium niobate, potassium dihydrogen phosphate and potassium phosphate dihydrate extinction ratio of deuterium Measuring method "to" measuring method "optical crystal extinction ratio. This part will also expand the scope of the standard to use other Wavelength measurement uniaxial optical crystal axis and the like; --- The original part of the measurement system extinction ratio indicators were modified, the original part of the measurement system indicators 100000, to be equipped with power output Higher rate (P≥15mW) helium-neon laser. Now part of the measurement system metrics revised 50000.1 using output power To 2mW of He-Ne laser; --- Original part extinction ratio index representation only ××××× .1 This section adds decibels method; --- This section would increase the measured crystal placed in the transmitted light intensity takes a maximum value when the orthogonal polarization system; --- This part of the measurement system should be used to increase the necessary light shielding requirements; --- This section increases the measuring environmental conditions; --- This section increases the measured roughness light through two crystal end surface; --- This section increases the aperture test systems for the provision of 5mm, the demand and supply sides also determined through negotiation based on the sample size The size of the optical aperture; --- This section increases the beam diameter of 90% of the diameter of the sample requirements, the demand and supply sides can also be determined based on a sample size of consultations Given the size of the beam diameter. This part is proposed by the Ministry of Industry and Information Technology of the People's Republic of China. This part of the jurisdiction of the China Electronics Standardization Institute. This in part by the China Electronics Technology Group Corporation Institute is responsible for drafting the twenty-sixth. The main drafters of this section. Xie Kecheng, Jinzhong Hong, Yang Jie, Zhang Xiaomei. This part of the standard replaces the previous editions are. --- GB/T 11297.12-1989. Measurement of optical crystal extinction ratio1 ScopeThis section GB/T 11297 provides for a wavelength of 632.8nm light waves along a single axis optical crystal axis direction extinction ratio measurement Volume method. This section applies to a wavelength of 632.8nm, 1064nm, 830nm, 514nm, 488nm, 458nm light waves and uniaxial Consumers and other optical crystal axis light than measurements.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated edition applies to this article Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 11293-1989 solid-state laser material Terminology3 Terms and DefinitionsGB/T 11293-1989 defined terms and definitions apply to this document.4 measuring principleWavelength 632.8nm measured along a bundle of light through a crystal optical axis disposed orthogonal polarization system tested crystals, Rotates about the optical axis of the crystal, the maximum transmitted light intensity is measured, then rotate the polarization analyzer into a parallel system, measure the transmitted light intensity value, through Through the formula (1) calculate the extinction ratio (EX). EX = I‖/I⊥ (1) Where. EX --- extinction ratio measured crystals; I‖ --- polarized parallel system transmitted light intensity value, in millivolts (mV); I⊥ --- orthogonal polarization system maximum transmitted light intensity, in millivolts (mV). Can also be used formula (2). EX '= 10 × lg (I‖/I⊥) (2) Wherein the extinction ratio EX 'decibels (dB).5 Measurement SystemExtinction ratio measuring system 1 shown in a schematic diagram, a wavelength of 632.8nm He-Ne laser light. FIG using other wavelengths of light When the wave measurement, simply replace the corresponding optical power meter and laser wavelength. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 11297.12-2012_English be delivered?Answer: Upon your order, we will start to translate GB/T 11297.12-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 11297.12-2012_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 11297.12-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 11297.12-2012?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 11297.12-2012 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |