GB/T 5023.3-2008 PDF EnglishUS$85.00 · In stock · Download in 9 seconds
GB/T 5023.3-2008: Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V -- Part 3: Non-sheathed cables for fixed wiring Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid GB/T 5023.3: Historical versions
Similar standardsGB/T 5023.3-2008: Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V -- Part 3: Non-sheathed cables for fixed wiring---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT5023.3-2008 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 29.060.20 K 13 GB/T 5023.3-2008 / IEC 60227-3.1997 Replacing GB 5023.3-1997 Polyvinyl Chloride Insulated Cables of Rated Voltages up to and Including 450/750V – Part 3.Non-Sheathed Cables for Fixed Wiring (IEC 60227.1997, IDT) Issued on: JUNE 30, 2008 Implemented on: MAY 1, 2009 Issued by. General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of PRC. Table of ContentsForeword... 3 1 General... 5 2 Single-Core Non-Sheathed Cable with Rigid Conductor for General Purposes... 6 3 Single-Core Non-Sheathed Cable with Flexible Conductor for General Purposes... 8 4 Single-Core Non-Sheathed Cable with Solid Conductor for Internal Wiring for a Conductor Temperature of 70°C... 11 5 Singe-Core Non-Sheathed Cable with Flexible Conductor for Internal Wiring for a Conductor Temperature of 70°C... 13 6 Single-Core Non-Sheathed Cable with Solid Conductor for Internal Wiring for a Conductor Temperature of 90°C... 15 7 Single-Core Non-Sheathed Cable with Flexible Conductor for Internal Wiring for a Conductor temperature of 90°C... 17ForewordGB/T 5023 Polyvinyl Chloride Insulated Cables of Rated Voltages up to and Including 450/750V is divided into 7 parts. --- Part 1.General Requirements; --- Part 2.Test Methods; --- Part 3.Non-Sheathed Cables for Fixed Wiring; --- Part 4.Sheathed Cables for Fixed Wiring; --- Part 5.Soft Cables (Soft Wires); --- Part 6.Lift Cables and Cables for Flexible Connections; --- Part 7.Flexible Cables Screened and Unscreened with Two or More Conductors. This Part is Part 3 of GB/T 5023.This Part equivalently adopts IEC 60227-3.1997 Polyvinyl Chloride Insulated Cables of Rated Voltages up to and Including 450/750V – Part 3.Non-Sheathed Cables for Fixed Wiring, Version 2.1 (English Edition). For ease of use, this Part of GB/T 5023 makes the following editorial changes. --- Use “decimal point” to replace the “comma” that acts as the decimal point --- Delete the Foreword of IEC 60227-3.1997. This Part replaces GB 5023.3-1997 Polyvinyl Chloride Insulated Cables of Rated Voltages up to and Including 450/750V. Compared with GB 5023.3-1997, this Part mainly has the following changes. --- Regulate the upper- and lower-limit against the overall diameter of 60227 IEC Model 01, 02, 05, 06, 07, 08, and other types of cables; adjust the upper limit of diameter of cables in the original standard (Table 1, 3, 5, 7, 9, 11); --- Modify 60227 IEC Model 01-type cable’s 35mm2 and 50mm2 minimum insulation resistance; 35mm2 corresponding minimum insulation resistance of 0.0040 MΩ•km was changed into 0.0043 MΩ•km; while 50mm2 corresponding minimum insulation resistance of 0.0045 MΩ•km was changed into 0.0043 MΩ•km. This Part was proposed by China Electrical Equipment Industrial Association. Polyvinyl Chloride Insulated Cables of Rated Voltages up to and Including 450/750V – Part 3.Non-Sheathed Cables for Fixed Wiring1 General1.1 Scope This Part of GB/T 5023 details the particular specifications for polyvinyl chloride insulated single-core non-sheathed cables for fixed wiring and rated voltages up to and including 450/750V. All cables shall comply with the appropriate requirements given in GB/T 5023.1, and the individual types of cables shall each comply with the particular requirements of this Part. 1.2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this part of GB/T 5023.For dated references, the subsequent amendments (excluding corrigendum) or revisions do not apply to this Part, however, parties who reach an agreement based on this Part are encouraged to study if the latest versions of these documents are applicable. For undated references, the latest edition of the referenced document applies. GB/T 2951.11-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 11.Methods for General Application - Measurement of Thickness and Overall Dimensions (IEC 60811-1-1.2001, IDT) GB/T 2951.12-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 12.Methods for General Application - Thermal Ageing Methods (IEC 60811-1-2.1985, IDT) GB/T 2951.14-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 14.Methods for General Application - Test at Low Temperature (IEC 60811-1-4.1985, IDT) GB/T 2951.31-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 31.Methods Specific to PVC Compounds - Pressure Test at High Temperature - Test for Anti-Crack (IEC 60811-3-1.1985, IDT) GB/T 2951.32-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 32.Methods Specific to PVC Compounds - Loss of Mass Test - Thermal Stability Test (IEC 60811-3-2.1985, IDT) GB/T 3956-1997 Conductors Of Insulated Cables (idt IEC 60228.1978) GB/T 5023.1 Polyvinyl Chloride Insulated Cables of Rated Voltages up to and Including 450/750V - Part 1.General Requirements (GB/T 5023.1-2008, IEC 60227-1.2007, IDT) GB/T 5023.2-2008 Polyvinyl Chloride Insulated Cables of Rated Voltages up to and Including 450/750V - Part 2.Test Methods (IEC 60227-2.2003, IDT) GB/T 18380.12-2008 Test on Electric and Optical Fiber Cables under Fire Conditions - Part 12.Test for Vertical Flame Propagation for a Single Insulated Wire or Cable (IEC 60332-1-2.2004, IDT)2 Single-Core Non-Sheathed Cable with RigidConductor for General Purposes 2.1 Code designation 60227 IEC 01 (BV). 2.2 Rated voltage 450/750V. 2.3 Construction 2.3.1 Conductor Number of cores. 1. The conductors shall comply with the requirements of GB/T 3956-1997. --- Class 1 for solid conductors; --- Class 2 for stranded conductors. 2.3.2 Insulation The extruded insulation shall be polyvinyl chloride compound of Type PVC/C applied ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. |