GB 4793.3-2008 English PDFUS$194.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB 4793.3-2008: Safety requirements for electrical equipment for measurement, control, and laboratory use -- Part 3: Particular requirements for laboratory equipment for mixing and stirring Status: Valid GB 4793.3: Historical versions
Basic dataStandard ID: GB 4793.3-2008 (GB4793.3-2008)Description (Translated English): Safety requirements for electrical equipment for measurement, control, and laboratory use -- Part 3: Particular requirements for laboratory equipment for mixing and stirring Sector / Industry: National Standard Classification of Chinese Standard: N09 Classification of International Standard: 19.080 Word Count Estimation: 10,190 Date of Issue: 2008-08-30 Date of Implementation: 2009-09-01 Older Standard (superseded by this standard): GB 4793.3-2001 Quoted Standard: GB 4793.1 Adopted Standard: IEC 61010-2-051-2005, IDT Regulation (derived from): Announcement of Newly Approved National Standards No. 14 of 2008 (total 127) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This Chinese standard relates to mechanical mixing and stirring electric laboratory equipment and accessories, and its mechanical energy impact materials and accessories for the shape, size and uniformity. Such apparatus may include a heating device. Note: If the device is either in whole or in part within the scope of this standard, and the other belonging to GB 4793 in one or more parts range, then it also needs to meet the GB 4793 other relevant standards. Having a heating device equipment requirements see GB 4793. 6. GB 4793.3-2008: Safety requirements for electrical equipment for measurement, control, and laboratory use -- Part 3: Particular requirements for laboratory equipment for mixing and stirring---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Safety requirements for electrical equipment for measurement, control, and laboratory use.Part 3. Particular requirements for laboratory equipment for mixing and stirring ICS 19.080 N09 National Standards of People's Republic of China GB 4793.3-2008/IEC 61010-2-051.2005 Replacing GB 4793.3-2001 Measurement, control and laboratory use electrical equipment Safety requirements - Part 3. Laboratory mixing and Special mixing equipment requirements (IEC 61010-2-051.2005, IDT) Published 2008-08-30 2009-09-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China issued Table of ContentsIntroduction Ⅲ And a range of object 1 2 Normative References 1 Terms and definitions 1 3 4 Test 1 5 Marking and documentation 1 6 against electric shock 2 7 against mechanical risk 2 8 mechanical shock resistance and impact 3 9 to prevent the spread of flame 3 The temperature limit device 10 and heat 3 11 dangerous fluid-3 12 radiation (including laser light source), an acoustic and ultrasonic pressure 3 13 pairs of released gases, explosion and implosion protection 3 14 Component 3 Protective interlock 15 using 3 16 test and measurement device 3 Appendix 4 Reference 5 GB 4793.3-2008/IEC 61010-2-051.2005ForewordAll technical contents of this section is mandatory. GB 4793 "measurement, control and laboratory safety requirements for electrical equipment" is currently divided into seven parts. --- Part 1. General requirements (IEC 61010-1); --- Part 2. Particular electrical measurement and test requirements held and hand operated current sensors (IEC 61010-2-032); --- Part 3. laboratory mixing and stirring equipment Particular requirements (IEC 61010-2-051); --- Part 4. Particular requirements for laboratory use (IEC 61010-2-041) Autoclave treatment of medical material; --- Part 5. Safety electrical measurement and test requirements of the handheld probe assembly (IEC 61010-031); --- Part 6. Laboratory Particular requirements (IEC 61010-2-010) heating of materials; --- part 7. Particular requirements for laboratory centrifuges (IEC 61010-2-020). Note. The name of the section will change with changes in IEC standard names. This is Part of 3 GB 4793. This section is equivalent to using IEC 61010-2-051.2005 "2-051 portion of measurement, control and laboratory safety requirements for electrical equipment for Point. Particular requirements for laboratory mixing and stirring equipment "(in English). Technical content, structure, and expression from the text IEC 61010-2-051.2005 exactly the same. For ease of use, the present editorial changes made the following section. --- with a decimal point "." Instead of a comma as the decimal point "." --- omitted 61010-2-051 IEC .2005 contents Foreword. --- For IEC 61010-2-051.2005 references other international standards have been adopted as identical or modified our standards, this Partially replaced with corresponding international standards of national standards or industry standards; the rest No equivalent or modify adopted as our standard Quasi-international standards, are directly referenced in this section. This section is GB 4793.3-2001 "measurement, control and laboratory use with electrical equipment safety laboratory mixing and stirring apparatus Special requirements "(IEC 61010-2-051.1995, IDT) revision. This section must be combined GB 4793.1 "measurement, control and laboratory use Part 1 safety requirements for electrical equipment. General Requirements" Since use. Stated in this section "applicable" portion represents the corresponding strips GB 4793.1 apply to this section; this section states that "place" or "Edit" section, to show that this part of the article subject; in this section indicate the "increase" portion, in addition to meeting indicate corresponding GB 4793.1 To section, this section must meet the increased strip. In order to distinguish the bar GB 4793.1, this part of the increase in the number of bars 101 open Beginning, e.g. 7.2.101. This part of GB 4793.3-2001 have more minor changes, some of the provision was changed in the text, along with a standard structure GB 4793.1-2007 been adjusted. This section was proposed by China Machinery Industry Federation. This part of the jurisdiction of the National measurement, control and electrical equipment Safety Laboratory Standardization Technical Committee (SAC/TC338). The drafting of this section. of Instrumentation Comprehensive Economic Institute of Technology. The main drafters of this section. Liu Xiaojing, Mei Ke, Zheng Xu, Wang Linkun, Ouyang Jinsong, when FANG Xiao, Wang Jianhua, Pan Changqing, Zhang Guiling. This section replaces the following previously issued as follows. --- GB 4793.3-2001. GB 4793.3-2008/IEC 61010-2-051.2005 Measurement, control and laboratory use electrical equipment Safety requirements - Part 3. Laboratory mixing and Special mixing equipment requirements1 Scope and PurposeExcept as follows, GB 4793.1 Chapter 1 apply. 1.1 Scope instead. Replace the entire text with the following. This section applies to the GB 4793 for mechanically mixing and stirring an electric laboratory equipment and accessories, which materials influence the mechanical energy And attachment shape, size and uniformity. Such apparatus may include heating means. NOTE. If the whole or part of the device both are within the scope of this section, and belongs to one or more other partial range GB 4793, then it needs to meet Requirements of other relevant standards in GB 4793. Requirements apparatus having heating means, see GB 4793.6.2 Normative referencesTerms of the following documents constitute provisions of this section by reference in this section 4793 of the GB . For dated references, All subsequent amendments (excluding corrections) or revisions do not apply to this section, however, encouraged to reach an agreement under this section Whether the parties to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section. GB 4793.1 measurement, control and laboratory use Part 1 safety requirements for electrical equipment. General requirements (GB 4793.1-2007, IEC 61010-1.2001, IDT) GB 4793.1 Chapter 2 apply.3 Terms and DefinitionsGB 4793.1 Chapter 3 apply.4 TestGB 4793.1 Chapter 4 shall apply.5 Marking and documentationExcept as follows, GB 4793.1 Chapter 5 are applicable. 5.4.1 Overview increase. Note as the original note 1, and 101 add the following note. 101 Note. If a mixer or blender as a handheld device operation may be dangerous, you should have a warning statement for this situation. 5.4.4 operating equipment increase. In i) later, add a new entry aa). aa) if a predetermined part of the stirred vessel and sell hybrid system or if there are other applications, installation instructions stirring vessel. Add the following new first paragraph after the second paragraph. GB 4793.3-2008/IEC 61010-2-051.2005 In the description shall be given a warning to prohibit the use of equipment or hazardous use of hazardous materials outside the range of the equipment design. instead. Instead of the original second paragraph (now the third paragraph) with the following. Should let users know if the equipment is not provided or recommended by the manufacturer of the accessory, or not in accordance with the manner specified by the manufacturer Equipment, the protection provided by the equipment might be reduced.6 against electric shockGB 4793.1 Chapter 6 apply.7 against mechanical hazardExcept as follows, GB 4793.1 Chapter 7 are applicable. instead. 7.2 Moving parts Instead of the second segment in the second row with the following "Example. drilling equipment and mixing equipment". For example. down cutting Ye Lun shaft and stirring the kneading material. Add the following article. 7.2.101 speed controller If the single failure of the electronic speed control can cause danger, the equipment should provide a method of preventing a power loss or other hazard. By visual inspection and testing to verify eligibility. Moving operation 7.2.102 You should not change in normal use position of the device. By visual inspection and testing to verify eligibility. After 10min mobile devices running distance of not more than 5mm, can be considered to meet This requirement. 7.2.103 restart after interruption Depending on the application, the mixing process is restarted after an interruption or restart may be dangerous. Equipment in response to the power grid And whether to restart after a power failure will be explained in the case of failure or mechanical suspension. Note. In some cases, there should be a visual or audible alarm to warn of disruptions occur. By examining the documents to verify eligibility. 7.2.104 dangerous application-related Dangerous cause cracking may occur when the device for mixing the combustible material, or transferred to a glass container occurs mechanical energy Danger. The instructions shall prohibit the use of warning devices in these applications, the danger to prevent a single fault condition unless the device is installed Respective safety device. Such safety devices should be independent of the control system. Example safety hazard and a corresponding device is as follows. a) In the mixing operation failure may be dangerous, such as a metal organic chemical reaction, the safety device should start the alarm signal is. 1) When the mixer or mixers can not rotate if the drive shaft; or 2) When the rotational speed of the shaft due to overload is below a predetermined rotational speed. Note 1. The shortage of power, or may decrease the device automatically starts when the shaft speed speed reduction caused by overload. b) applying an excessive torque to the high viscosity material may be dangerous, such as glass breakage occurs. If the torque exceeds a preset level, security Full warning signal means should be started. Note 2. It is recommended safety devices work in accordance with the principle of the residual current. By visual inspection and testing to verify eligibility. GB 4793.3-2008/IEC 61010-2-051.20058 mechanical shock resistance and impactChapter 8 GB 4793.1 apply.9 to prevent the spread of flameGB 4793.1 Chapter 9 apply. The temperature limit device 10 and heat GB 4793.1 Chapter 10 are applicable. 11 Anti-dangerous fluid In addition to the following conditions, GB 4793.1 Chapter 11 are applicable. Add the following article. 11.101 conduit connecting hose The connector should be designed so that the hose can not be releasable, for example using a hose clamp, and the catheter should be sufficiently secured. By visual inspection to verify eligibility. 12 radiation (including laser light source), an acoustic and ultrasonic pressure GB 4793.1 Chapter 12 apply. 13 pairs of released gases, explosion and implosion protection In addition to the following conditions, GB 4793.1 Chapter 13 are applicable. Add the following article. 13.2.101 explosion and implosion protection Depending on the type, location and mode of operation, proof, or device designed for use with explosive should meet the IEC and ISO The relevant requirements of the standard. By tested according to relevant standards to verify eligibility. 14 components GB 4793.1 Chapter 14 apply. 15 with the protective interlock GB 4793.1 Chapter 15 are applicable. Test and measurement equipment 16 Chapter 16 GB 4793.1 apply. GB 4793.3-2008/IEC 61010-2-051.2005 appendix GB 4793.1 Appendix apply. GB 4793.3-2008/IEC 61010-2-051.2005 references Except for the following content, GB 4793.1 references apply. increase. GB 4793.6 measurement, control, and laboratory safety requirements for electrical equipment with Part 6. Laboratory special heating equipment material Requirements (GB 4793.6-2008, IEC 61010-2-010.2005, IDT). GB 4793.3-2008/IEC 61010-2-051.2005 ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB 4793.3-2008_English be delivered?Answer: Upon your order, we will start to translate GB 4793.3-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB 4793.3-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB 4793.3-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB 4793.3-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 4793.3-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |