Home   Cart   Quotation   Policy   About-Us
www.ChineseStandard.net
SEARCH

GB 23553-2009 English PDF

US$319.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB 23553-2009: [GB/T 23553-2009] Prometryn wettable powders
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB 23553-2009319 Add to Cart 3 days [GB/T 23553-2009] Prometryn wettable powders Valid

Similar standards

GB/T 38211   GB/T 18418   GB/T 18419   GB/T 23554   GB/T 23549   GB 23548   

Basic data

Standard ID: GB 23553-2009 (GB23553-2009)
Description (Translated English): [GB/T 23553-2009] Prometryn wettable powders
Sector / Industry: National Standard
Classification of Chinese Standard: G25
Classification of International Standard: 65.100.20
Word Count Estimation: 12,143
Date of Issue: 2009-04-27
Date of Implementation: 2009-11-01
Regulation (derived from): Announcement of Newly Approved National Standards No. 5, 2009 (No. 145 overall)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This Chinese standard specifies the prometryne WP requirements, test methods and marking, labeling, packaging, storage and transportation. This standard applies to Prometryne original drug, suitable additives and fillers from the processing Prometryne WP.

GB 23553-2009: [GB/T 23553-2009] Prometryn wettable powders

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Prometryn wettable powders ICS 65.100.20 G25 National Standards of People's Republic of China Prometryne WP Posted 2009-04-27 2009-11-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

The standard Chapter 3, Chapter 5 are mandatory, the rest are recommended. Appendix A of this standard is the data appendix. Since the implementation of this standard, the original industry standard HG2202-1991 "Prometryne WP" void. The standard proposed by China Petroleum and Chemical Industry Association. This standard by the National Standardization Technical Committee on Pesticides (SAC/TC133) centralized. This standard is drafted by. Shenyang Chemical Research Institute. Participated in the drafting of this standard. Yunnan Chemical Research Institute. The main drafters of this standard. Wang Yufan, Zhangxue Bing, Chen Meng Liang Xuesong. Prometryne WP The product's active ingredient Prometryne other name, structural formula and basic physicochemical parameters are as follows. ISO common name. prometryn CIPAC Numeric Code. 93 Chemical name. 4,6-bis-isopropylamino-2-methylthio-s-triazine Structure. Empirical formula. C10H19N5S Molecular Weight. 241.4 (according to 2005 international relative atomic mass) Biological activity. weeding Melting point. 118 ℃ ~ 120 ℃ Vapor pressure (20 ℃). 0.133mPa Solubility (20 ℃). water 33mg/L; acetone 240g/L; dichloromethane 300g/L; hexane 5.5g/L; methanol 160g/L; octanol 100g/L; toluene 170g/L. Stability. neutral, slightly acidic or slightly alkaline medium (20 ℃) stability to hydrolysis. This product is alkaline soils DT5040d ~ 70d

1 Scope

This standard specifies the Prometryne WP requirements, test methods and marking, labeling, packaging, storage and transportation. This standard applies to the Prometryne original drug, suitable additives and fillers processed Prometryne WP.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 1600 Determination of Water Pesticides Determination of GB/T 1601 Pesticides pH value GB/T 1604 Goods pesticide regulations for acceptance GB/T 1605-2001 Sampling Method commercial pesticides GB 3796 pesticide packaging General GB/T 5451 WP Pesticide wettability measurement method GB/T 14825-2006 Method for determination of pesticide suspension GB/T 16150 pesticide powder, wettable powder fineness measurement method GB/T 19136 Determination of Pesticide Thermal storage stability

3 Requirements

3.1 Composition and appearance This product should be compliant Prometryne original drug with suitable additives and fillers processing is made uniform loose powder, there should be no lumps. 3.2 Technical Specifications Prometryne WP should meet the requirements of Table 1. Table 1 Prometryne WP Quality Control Project Index project index 50% 40% 25% Prometryne mass fraction /% 50.0 + 40.0 + 2.0-2.0 2.5-2.5 1.5-1.5 25.0 + Moisture /% ≤ 3.0 pH range 6.0 to 10.0 Suspension rate /% ≥ 70 Wetting time/s ≤ 120 Fineness (through 45μm test sieve) /% ≥ 98 Thermal storage stability test a qualified When a normal production, heat storage stability test was measured at least once every three months. Test Method 4 4.1 Sampling According to GB/T 1605-2001 "on solid preparation sampling" approach. Determining sample package using a random number table method; the final sample size Not less than 300g. 4.2 Identification Test Gas Chromatography --- The identification test can be carried out simultaneously with the determination of the mass fraction of Prometryne. Under the same chromatographic operating conditions, the test A sample solution peak retention time with the standard solution flutter grass net retention time in peaks, the relative difference should be 1.5% Fewer. 4.3 Determination of the mass fraction of Prometryne 4.3.1 Method summary Sample was dissolved in chloroform to triadimefon as internal standard, the use of the inner wall of the bonded Carbowax 20M capillary column and flame Ionization detector to sample Prometryne gas chromatographic separation and determination. You can also use packed column gas chromatography, chromatographic conditions Senate See Appendix A. 4.3.2 Reagents and solutions Chloroform; Triadimefon. should not interfere with the analysis of impurities, ≥95%; Prometryne Sample. Known Prometryne mass fraction ≥99.0%; Internal standard solution. Weigh 8.6g triadimefon, placed 1000mL volumetric flask with chloroform to dissolve and dilute to volume, shake. 4.3.3 Instruments Gas chromatograph. with a hydrogen flame ionization detector; Chromatographic data processor or chromatography workstation; Column. 30m × 0.32mm (. I.d) capillary column, wall-bonded polyethylene glycol 20M, film thickness 0.25μm; Micro injector. 10μL. 4.3.4 GC operating conditions Temperature (℃) Temperature. 195 gasification chamber. 230, detection chamber. 230; Gas flow rate (mL/min). carrier gas (N2) 2.0, hydrogen gas 30, air 300; Injection volume (μL). 1.0; Retention time (min). Prometryne about 4.2, internal standard (triadimefon) about 5.6. GC operating conditions described above, the Department of typical operating parameters. According to the characteristics of different instruments, given operating parameters adjusted as appropriate, In order to obtain the best results. Typical Prometryne wettable powder with a gas chromatograph internal standard is shown in Figure 1. 1 --- Prometryne; 2 --- internal standard (triadimefon). Figure 1 Prometryne WP and the internal standard gas chromatograph 4.3.5 measuring step 4.3.5.1 preparation of standard solution Weigh Prometryne standard 0.1g (accurate to 0.0002g), placed in 15mL stoppered glass bottle with a pipette moved 10mL internal standard Solution, shake. 4.3.5.2 preparation of the sample solution It weighs about 0.1g sample containing Prometryne of (accurate to 0.0002g), placed in 15mL stoppered glass bottle, in use with 4.3.5.1 With a pipetted into internal standard solution 10mL, shake. 4.3.5.3 Determination Under these operating conditions, the instrument until a stable baseline, the number of continuous injection doses of the standard solution, calculated for each needle Prometryne and the internal standard peak area Repeatability ratio, when two needles Prometryne relative change compared with the internal standard peak area of less than 1.2%, according to the standard solution, sample to be adjacent Solution, sample solution, the order of the standard solution was measured. 4.3.6 Calculation The two needle sample solution and measured before and after the two doses of the standard sample solution Prometryne and the internal standard peak area ratio in the average respectively. Prometryne sample mass fraction of 1 (%), according to equation (1). 1 = (1) Where. --- Prometryne standard mass fraction, expressed as a percentage. 4.3.7 allowable difference The difference between two parallel determination results, 25% should be no more than 0.5%, 50% and 40% should not exceed 1.0%, respectively, and the arithmetic mean As a measurement result. 4.4 Determination of Moisture According to GB/T 1600 in the "azeotropic distillation method". According to GB/T 1601 carried out. 4.6 Determination of the suspension rate Weigh 0.4g sample containing Prometryne of (accurate to 0.0002g), according to GB/T 14825-2006 4.1 performed. The cylinder bottom 25mL suspension and precipitate in a water bath to dryness, and then returned to room temperature measured by the mass fraction of 4.3 Prometryne calculate the suspension rate. 4.7 Determination of wetting time According to GB/T 5451 carried out. 4.8 Determination of fineness According to GB/T 16150 in the "wet sieve method". 4.9 Thermal storage stability test According to GB/T 19136 in "powder formulations" to. After the heat storage Prometryne content should not be less than the reservoir Qianpu grass net mass fraction 97% suspension rate should meet the standard requirements. 4.10 Product inspection and acceptance Product inspection and acceptance shall comply with GB/T 1604's. Treatment of extreme values using the rounding value comparison method. 5 marking, labeling, packaging, storage and transportation WP 5.1 Prometryne signs, labeling and packaging should comply with the provisions of GB 3796. WP 5.2 Prometryne aluminum foil bag or plastic bag, net weight of 100g, 200g, 250g, 500g; packaging can Cartons, corrugated cardboard box or Plastic boxes each containing a net content not exceeding 20kg. Also available upon request or order agreement, the use of other forms of Type of packaging, subject to the provisions of GB 3796. 5.3 Prometryne WP package should be stored in well-ventilated, dry coffers. 5.4 storage, prevent moisture and sunlight, no food, seed, feed mix, avoid contact with skin, eyes, mouth and nose to prevent inhalation. 5.5 Security. Prometryne low toxicity herbicides. The FDA should wear protective gloves. Nose and mouth to prevent inhalation, or skin contact with exposed parts of the body The goods should be promptly washed with soap and water. In case of poisoning should promptly consult a doctor. 5.6 Warranty. under the specified storage conditions Prometryne guarantee wettable powder, from date of manufacture for 2 years.

Appendix A

(Informative) Prometryne content packed column gas chromatographic method A. 1 Method summary Sample was dissolved in chloroform to triadimefon as internal standard, using polyethylene glycol 20M/GasChromQ packed column and flame Ionization detector to sample Prometryne gas chromatographic separation and determination. A. 2 Reagents and solutions Chloroform; Triadimefon. should not interfere with the analysis of impurities, ≥95%; Prometryne Sample. Known Prometryne mass fraction ≥99.0%; Internal standard solution. Weigh 10.0g of triadimefon, placed 1000mL volumetric flask with chloroform to dissolve and dilute to volume, shake. A. 3 Instrument Gas chromatograph. with a hydrogen flame ionization detector; Chromatographic data processor or chromatography workstation; Column. 3% polyethylene glycol 20M/GasChromQ (80 mesh to 100 mesh) stainless steel column (column or glass); Micro injector. 10μL. A. 4 GC operating conditions Temperature (℃).200 Column temperature gasification chamber 230, the detector chamber 230; Gas flow rate (mL/min). carrier gas (N2) 80, hydrogen gas 40, air 400; Injection volume (μL). 1.0; Retention time (min). Prometryne about 5.2, about 7.0 internal standard. GC operating conditions described above, the Department of typical operating parameters. According to the characteristics of different instruments, given operating parameters adjusted as appropriate, In order to obtain the best results. Typical Prometryne original drug and the internal standard packed column gas chromatography is shown in Figure A. 1. 1 --- Prometryne; 2 --- internal standard (triadimefon). Figure A. 1 Prometryne WP and the internal standard packed column gas chromatogram A. 5 measuring step A. 5.1 preparation of standard solution Weigh Prometryne standard 0.1g (accurate to 0.0002g), placed in 15mL stoppered glass bottle with a pipette accurately transferred to 10mL Internal standard solution, and shake. A. 5.2 Sample preparation solution It weighs about 0.1g sample containing Prometryne of (accurate to 0.0002g), placed in 15mL stoppered glass vial, with A. 5.1 used With a pipette accurately transferred to the internal standard solution 10mL, shake. A. 5.3 Determination Under these operating conditions, the instrument until a stable baseline, the number of continuous injection doses of the standard solution, calculated for each needle Prometryne and the internal standard peak area Repeatability ratio, when two needles Prometryne relative change compared with the internal standard peak area of less than 1.2%, according to the standard solution, sample to be adjacent Solution, sample solution, the order of the standard solution was measured. A. 6 Calculation The two needle sample solution and measured before and after the two doses of the standard sample solution Prometryne and the internal standard peak area ratios are averaged. Flutter grass net sample mass fraction of 1 (%) according to equation (A.1) Calculated. 1 = (A.1) Where. --- Prometryne standard mass fraction, expressed as a percentage. A. 7 allowable difference The difference between two parallel determination results, 25% should be no more than 0.5%, 50% and 40% should not exceed 1.0%, respectively, and the arithmetic mean As a measurement result.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB 23553-2009_English be delivered?

Answer: Upon your order, we will start to translate GB 23553-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB 23553-2009_English with my colleagues?

Answer: Yes. The purchased PDF of GB 23553-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.