GB 19510.3-2009 English PDF

US$494.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB 19510.3-2009: Lamp controlgear -- Part 3: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps
Status: Valid

GB 19510.3: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB 19510.3-2009494 Add to Cart 4 days Lamp controlgear -- Part 3: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps Valid
GB 19510.3-2004999 Add to Cart 4 days Lamp controlgear -- Part 3: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps Obsolete

Similar standards

GB/T 9473   GB/T 24825   GB/T 32483.2   GB/T 19510.1   GB 19510.1   GB 19510.2   

Basic data

Standard ID: GB 19510.3-2009 (GB19510.3-2009)
Description (Translated English): Lamp controlgear -- Part 3: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps
Sector / Industry: National Standard
Classification of Chinese Standard: K74
Classification of International Standard: 29.140.99
Word Count Estimation: 25,276
Date of Issue: 2009-10-15
Date of Implementation: 2010-12-01
Older Standard (superseded by this standard): GB 19510.3-2004
Adopted Standard: IEC 61347-2-2-2006, IDT
Regulation (derived from): Announcement of Newly Approved National Standards No. 11 of 2009 (No. 151 overall)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This Chinese standard specifies the tungsten halogen lamps and other electronic buck converter with the special requirements of this electronic buck converter using 250 V DC or less than 1 000 V or less 50 Hz/60 Hz to 1 000 V AC power supply below, and its conductors or between a conductor and ground any arising between the nominal output voltage �� 50 V (rms, frequency different from the power supply frequency) �� 50 �� 2 V (pulsating DC power supply).

GB 19510.3-2009: Lamp controlgear -- Part 3: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Lamp controlgear.Part 3. Particular requirements for dcor acsupplied electronic step-down convertors for filament lamps ICS 29.140.99 K74 National Standards of People's Republic of China GB 19510.3-2009/IEC 61347-2-2.2006 Replacing GB 19510.3-2004 Part 3 of the control device lamp. filament lamps Particular requirements for AC/DC electronic buck converter (IEC 61347-2-2.2006, IDT) Posted 2009-10-15 2010-12-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ Introduction Ⅴ 1 Scope 1 2 Normative references 1 3 Terms and definitions 2 4 3 General requirements 5 3 Test Description 6 Category 3 7 mark 3 8 accidental contact with live parts of the measures to prevent 3 Terminal 4 9 10 grounding device 4 11 Moisture resistance and insulation 4 12 Dielectric strength 4 Heat winding 13 Test 4 14 Fault Status 4 Heating transformer 15 Test 5 16 abnormal state 5 17 Structure 5 18 creepage distances and clearances 5 19 Screws, current-carrying parts and connections 6 20 heat, fire and resistance to tracking 6 21 corrosion 6 Test Appendix A (normative) to determine whether a conductive part is a live part may cause an electric shock 7 Appendix B (normative) Particular requirements for thermal control device 7 protected lamp Particular requirements 7 Annex C (normative) with thermal protector electronic control unit lamp Annex D (normative) heating test control apparatus for thermally protected lamp of claim 7 Annex F (normative) anti-convection air chamber 7 Derivation of Annex G (informative) values of pulse voltages 7 Annex H (normative) Test 8 Annex I (normative) Tungsten with independent safety extra-low voltage dc or ac supplied electronic step-down converters special Additional requirements 8 GB 19510.3-2009/IEC 61347-2-2.2006

Foreword

All technical content in this section is mandatory. GB 19510 "Lamp control" is divided into 14 parts. --- Part 1. General requirements and safety requirements; --- Part 2. starting devices (other than glow starters) - Particular requirements; --- Part 3. Tungsten with AC/DC buck converter electronic Particular requirements; --- Part 4. Particular requirements for the exchange of electronic fluorescent ballasts; --- Part 5. Particular requirements for dc supplied electronic ballasts for general lighting of; --- Part 6. Particular requirements for dc public transport lighting ballasts; --- Part 7. DC electronic ballasts for aircraft lighting Particular requirements; --- Part 8. DC electronic ballasts for emergency lighting Particular requirements; --- Part 9. Particular requirements for ballasts for fluorescent lamps; --- Part 10. discharge lamps (excluding fluorescent lamps) with the special requirements of the ballast; --- Part 11. high frequency cold start tubular discharge lamps (neon) Specific requirements for electronic exchange and the frequency converter; --- Part 12. Particular requirements for lamps miscellaneous electronic circuits; --- Part 13. discharge lamps (excluding fluorescent lamps) or AC supplied electronic ballasts for special requirements; Part --- Article 14. LED module with special requirements for dc or ac electronic control device. This section GB Part 3 of 19510.3. This section should be used with GB 19510.1-2009, it is appropriate in terms of GB 19510.1-2009 supplement or repair Formulated from the following changes. This section identical with IEC 61347-2-2.2006 "Part 2-2 tungsten lamp control unit with AC/DC electronic Buck Particular requirements for converter "(in English). This section is equivalent translation IEC 61347-2-2.2006. For ease of use, this section made the following editorial changes. a) "IEC 61347-2-2" to "this Part"; b) Remove the preface IEC 61347-2-2, IEC 61347-2-2 revised introduction; c) The international standard "(note .)" form brackets removed; d) as a decimal by decimal points instead of "and", "."; e) For other international standards referenced it has been adopted as the equivalent of a standard, this part of the country with reference to these national standards Or industry standards instead of the corresponding international standards, and the rest not tantamount to the adoption of a standard for the international standards in this section are Direct reference (see Part 2 of this chapter). This Part replaces GB 19510.3-2004 "Part 3 control Lamp. Tungsten with AC/DC electronic buck converter special requirements". The main difference between this part and GB 19510.3-2004 follows. --- Chapter 2 Normative references in addition to the standard IEC 60384-14.2005; --- Chapter 5 test instructions to increase output cable test requirements and instructions; Increased explanatory declaration allows cable lengths of 7.2 --- supplementary signs; --- Chapter 16 increase in the abnormal state test contents and requirements; --- Table I. 7 types of insulation 3) canceled in accordance with the current classification and corresponding data changes. GB 19510.3-2009/IEC 61347-2-2.2006 This part of the Annex A, Annex B, Annex I to the normative Appendix C, Appendix D, Appendix E, Appendix F, Appendix H and Appendix Appendix G to Informative appendix. This part is proposed by the China National Light Industry Council. This part of the National Electric lighting Standardization Technical Committee (SAC/TC224) centralized. This section drafted by. National Electric Light Source Quality Supervision and Inspection Center (Shanghai), Guangzhou, China and Germany Electronic Co., Ltd., Zhongshan City, according to Op Ming Co., Ltd., NVC Lighting Technology Co., Ltd. Zhongshan lighting products, electrical systems technology can 霍尼韦尔朗 (Canton East) Limited. Drafters of this section. Chen Ying, Yuan Qi, Malaysians, Zhou Mingxing, Xiong Fei, Jiang Zhiqiang, Fu Baocheng, Levi liters. This section was first released in 2004, this revision is the first time. GB 19510.3-2009/IEC 61347-2-2.2006

Introduction

This section constitutes GB 19510.2 ~ GB and various provisions of section 19510.14, in applying any provision of GB 19510.1-2009 The terms of the scope and implementation of the order of the trial, but also provides the necessary additional requirements. GB 19510.2 ~ GB 19510.14 Each part is separate, and do not refer to each other. If this section by "a section in accordance with GB 19510.1-2009 requires," this sentence to refer to the GB 19510.1-2009 A provision requirements, the meaning of this statement is in accordance with all the requirements of this provision, but obviously does not apply to GB 19510.2 ~ Except for the contents of the control device GB 19510.14 specific type of lamp. GB 19510.3-2009/IEC 61347-2-2.2006 Part 3 of the control device lamp. filament lamps Particular requirements for AC/DC electronic buck converter

1 Scope

This part of GB 19510 specifies the special requirements of IEC 60357 and other tungsten halogen lamps with electronic step-down converter, which Of electronic buck converter uses the following 250V DC or less 1000V AC 50Hz/60Hz below the 1000V Power source wire or between any arising between a conductor and ground of the rated output voltage ≤50V (RMS, frequency different from the mains frequency Rate) or ≤ Sang 50 2V (pulsating DC power supply). NOTE. 50V rated output voltage limit in line with GB/T 18379 requirements in section Ⅰ of voltage. Particular requirements for thermal protection fitted with an electronic device buck converter is given in Appendix C. As the special requirements for fixed independent safety extra low voltage converter circuit is part of the device is given in Appendix I. Performance requirements are given in GB 19654. As a plug-in converter lighting fixture components reference standard supplementary requirements, it can be regarded as built-in converter.

2 Normative references

The following documents contain provisions which, through reference in this Part of GB 19510, constitute provisions of this part. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section. This part is described in GB 19510.1-2009 Chapter 2 normative references and normative references the following documents. Particular requirements for lamps with built - in transformers or converters for filament lamps (GB 7000.6-. GB 7000.6 Luminaires - Part 2-6 2007, IEC 60598-2-6.1996, IDT) GB/T 7676 (all parts) Direct acting indicating analogue electrical measuring instruments and their accessories (GB/T 7676-1998, idt IEC 60051) GB/T 13539.2 low-voltage fuses - Part 2. Supplementary requirements for fuses for use by authorized persons (mainly used for melting industry Breaker) example of standardized systems of fuses A to I (GB/T 13539.2-2008, IEC 60269-2.2006, IDT) GB 13539.3-2008 Low-voltage fuses - Part 3. unskilled personnel Supplementary requirements for fuses (mainly used in home With fuses and similar applications) example standardized systems of fuses A to F (IEC 60269-3.2006, IDT) GB/T 18379 Buildings voltage section (GB/T 18379-2001, idt IEC 60449. 1973) Electrical installations of Part 1 GB 19510.1-2009 lamp control apparatus. General and safety requirements (IEC 61347-1.2000, IDT) GB/T 11021 heat-resistant electrical insulation classification (GB/T 11021-2007, IEC 60085.2004, IDT) Part 4-41 GB 16895.21 Electrical installations of buildings. Protection for safety Protection against electric shock (GB 16895.21-2004, IEC 60364-4-41.2001, IDT) GB 19654 for filament lamps Annex AC/DC buck converter electronic performance requirements (GB 19654-2005, IEC 61047.1991, IDT) Safety requirements IEC 60065 grid power supply for household and similar general use of electronic and related equipment IEC 60083 IEC member countries have standardized household and similar purposes plugs and sockets IEC 60127 (all parts) miniature fuses IEC 60269-2-1.2000 low-voltage fuses - Part 2-1. fuses for use by authorized persons Supplementary requirements (industrial fuses) GB 19510.3-2009/IEC 61347-2-2.2006 Chapter Ⅰ ~ Ⅴ. Examples of types of standardized fuses IEC 60357 halogen lamps (non-motorized vehicles) IEC 60384-14.2005 Fixed capacitors for use in electronic equipment - Part 14. Electromagnetic Immunity and connected to the supply of fixed capacitance IEC 60454 (all parts), electrical laminated tape specifications IEC 60742. 1983 type isolation transformers and safety isolating transformers requirements (and amendment 1 (1992)) IEC 60906 (all parts) for household and similar purposes IEC plugs and sockets IEC 60906-1 for household and similar purposes IEC plugs and sockets - Part 1. 250V AC 16A plug and socket

3 Terms and Definitions

This section uses the following terms and definitions as well as the terms and definitions given in Chapter 3 GB 19510.1-2009. 3.1 Installed between the power supply and the other one, or several, or tungsten halogen lamps used to provide the rated voltage of the device is a lamp, the apparatus generally Work at high frequencies, which consists of one or several individual member, may also include dimming, correcting the power factor and suppressing radio dry Scrambling device. 3.2 Equipped to make one or a few parts of tungsten working stable converters typically operate at high frequencies. 3.3 Its output voltage is equivalent safety extra-low voltage and enables the work of one or a few built-in tungsten or modular converter. Note. For the purposes of this section, in line with the provisions of 8.1 and 8.2 equivalent safety extra-low voltage converter of available protection against electric shock and may be regarded as safety extra-low Voltage equivalent. 3.4 To provide isolated power supply safety extra-low output voltage converters under the 1983 safety isolating transformer. by IEC 60742. 3.5 Designed for the particular device or instrument power converter, which can be installed in or attached to such devices and instruments, but it is designed for With this particular apparatus and equipment designed for use together. 3.6 Converters installed or easily moved to another place in the converter from one place. 3.7 Mounted within the housing and includes a power supply for connecting monolithic plug converter. 3.8 Rated supply voltage, rated frequency and power factor is determined when a converter output voltage. 3.9 At the end of lamp life, or crystal deformation effect due to the heater filament leads to partial short circuit that may arise, this effect can cause conversion The overload. GB 19510.3-2009/IEC 61347-2-2.2006 3.10 It may occur when the voltage is within the bulb and can cause an effect ≥20V converter overload.

4 General requirements

In accordance with the requirements of this section of Chapter 4 GB 19510.1-2009 in the following additional requirements. Independent safety extra-low voltage converter should be in accordance with Annex I requirements. These requirements include insulation resistance, dielectric strength, creepage housing Distances and clearances.

5 Test Description

In accordance with the requirements of GB 19510.1-2009 Chapter 5 as well as the following additional requirements. Number of samples The following number of samples shall be submitted for testing. --- For Test Chapter 6 - Chapter 12 and Chapter 15 ~ Chapter 21 of the regulations, submit a sample; --- For Chapter 14 under the test, submit a sample (if necessary, in consultation with the manufacturer to request additional samples). Unless the manufacturer specifically stated test uses 20cm or 200cm long output cable, and select the most unfavorable test conditions. may Words or H03VV twisted pair cable. Decided by the rated power conductor cross-sectional size of the normal use of the current density does not exceed 5A/mm2. Category 6 Converter method according to GB 19510.1-2009 given in Chapter 6 and the following classification methods. The anti-shock protection measures are divided into. --- Equivalent safety extra-low voltage or isolated converter (converters of this type can be used instead of the double winding having reinforced insulation Transformers, see GB 7000.6); --- Auto converter; --- Independent safety extra low voltage converter.

7 logo

7.1 Mandatory Signs Converter (except integral converter) should be in accordance with the requirements of 7.2 GB 19510.1-2009 marked with the following mandatory signs, signs should Clear and durable. --- GB 7.1 of a 19510.1-2009 a), b), c), d), e), f), k), l), m) the content; and --- Rated output voltage. 7.2 Supplementary flag In addition to these mandatory sign, should also apply to the following content is marked on the converter, or marked on the manufacturer's catalog or the like, said Ming book. --- GB 7.1 in h), i) and j) 19510.1-2009 the content; and --- On whether converter connected to the mains winding instructions; --- Equivalent on safety extra-low voltage converter instructions (if applicable); --- If the output cable length between 20cm ~ 200cm, should be declared permissible cable length.

8 measures to prevent accidental contact with live parts

GB 19510.1-2009 accordance with the requirements of Chapter 10, and the following additional requirements. GB 19510.3-2009/IEC 61347-2-2.2006 8.1 For the equivalent safety extra-low voltage converter should be double or reinforced insulation so that it is easily accessible parts and live parts insulation. It should also be in accordance with IEC 60065 requirements of 9.3.4 and 9.3.5. 8.2 equivalent safety extra-low voltage output of the converter circuit in the following cases can be equipped with exposed terminals. --- Rated output voltage under load of not more than 25V (rms); --- No-load output voltage does not exceed 33V (rms) or Sang 33 2V (peak) or Sang 33 2V (pulsating DC current). Compliance is checked by the following test. the converter is rated supply voltage and rated frequency and reaches a steady state, and then measured Output voltage. When tested under load, to be mounted on the converter to produce a rated output at rated output voltage resistance. For having more than one rated supply voltage converter, this requirement applies to each of the rated supply voltage. NOTE. 25V (rms) limit based on GB 16895.21 draw. Rated output voltage exceeds 25V converters should be fitted with insulated terminals. In the case of equivalence between safety extra low voltage output and a capacitor connected to the primary circuit, use conform to IEC 60384-14. 2005 in Table 2 and Table 3 shows the test requirements and a single capacitor in series Y1 or two capacitors with the same parameter values Y2. There is resistance in case of equivalent safety extra-low voltage between the output lines and primary line connection, the two should be used in series and having the same A resistance parameter values. If you need additional element isolation transformer jumper, such as resistors, shall be in accordance with IEC 60065 Chapter 14 requirements. 8.3 is equipped with a total capacity of more than 0.5μF capacitor converters, it shall be constructed with the rated voltage of the power supply is disconnected 1min later, its terminal voltage does not exceed 50V.

9 Terminals

GB 19510.1-2009 accordance with Chapter 8 requirements. 10 grounding device In accordance with the requirements of GB 19510.1-2009 Chapter 9. 11 Moisture resistance and insulation In accordance with the requirements of GB 19510.1-2009 Chapter 11 as well as the following additional requirements. For the equivalent safety extra-low voltage converters, insulating its input and output are not connected between should fully meet the requirements. For double or reinforced insulation resistance should be not less than 4MΩ. 12 Dielectric strength In accordance with the requirements of GB 19510.1-2009 Chapter 12 as well as the following additional requirements. Winding insulation conditions equivalent safety extra-low voltage converter within the isolation transformer should be in accordance with IEC 60065 14.3.2 of the Claim. Heat test 13 windings GB 19510.1-2009 not in accordance with the requirements of Chapter 13. 14 Fault Status In accordance with the requirements of GB 19510.1-2009 Chapter 14 as well as the following additional requirements. In the case of the converter landmark, the converter shall meet the requirements specified in Appendix C. GB 19510.3-2009/IEC 61347-2-2.2006 In addition, when the converter is operating in a fault condition, the output voltage should not exceed 115% of the rated output voltage. 15 transformer heating tests Equivalent safety extra-low voltage converter isolation transformer windings shall be in accordance with the requirements of IEC 60065 7.1 were tested. 15.1 normal operation For normal operation, the value of IEC 60065 Table 3 Ⅰ column should be shown. 15.2 abnormal operation For this part of the work of Chapter 16 of the abnormal state and Chapter 14 of the fault condition should be used in Table 3 IEC 60065 ......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB 19510.3-2009_English be delivered?

Answer: Upon your order, we will start to translate GB 19510.3-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB 19510.3-2009_English with my colleagues?

Answer: Yes. The purchased PDF of GB 19510.3-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB 19510.3-2009?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 19510.3-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.