GB 15605-2024: Specifications for pressure venting of dust explosion
Status: Valid

GB 15605: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB 15605-2024839 Add to Cart 6 days Specifications for pressure venting of dust explosion Valid
GB/T 15605-2008135 Add to Cart Auto, < 3 mins Guide for pressure venting of dust explosions Valid
GB/T 15605-1995RFQ ASK 9 days Guide for venting of dust explosions Obsolete

Similar standards

GB 17440   GB 15577   GB 17440   GB/T 15604   GB/T 15604   

Basic data

Standard ID: GB 15605-2024 (GB15605-2024)
Description (Translated English): Specifications for pressure venting of dust explosion
Sector / Industry: National Standard
Classification of Chinese Standard: C67
Classification of International Standard: 13.230
Word Count Estimation: 42,447
Date of Issue: 2024-12-31
Date of Implementation: 2026-01-01
Older Standard (superseded by this standard): GB/T 15605-2008
Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration

GB 15605-2024: Specifications for pressure venting of dust explosion

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 13.230 CCSC67 National Standard of the People's Republic of China Replace GB/T 15605-2008 Dust explosion venting regulations Released on 2024-12-31 2026-01-01 implementation State Administration for Market Regulation The National Standardization Administration issued

Table of Contents

Preface III 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Technical Requirements 3 4.1 General requirements 3 4.2 Design and selection 4 4.3 Requirements for explosion venting devices 5 Installation, use and maintenance 6 5.1 Installation and Use 6 5.2 Inspection, maintenance and repair 6 6 Verification Methods 6 Appendix A (Normative) Calculation of pressure relief area of container 7 A.1 General requirements 7 A.2 Explosion relief of independent containers 7 A.3 Special dust cloud conditions 8 A.4 Explosion protection of interconnected container systems 9 A.5 Effect of pressure relief duct 10 A.6 Heterogeneous mixtures 11 Appendix B (Informative) Pressure relief area calculation example 13 B.1 Calculation of pressure relief area of containers and silos 13 B.2 Effect of pressure relief duct on vessel design strength 14 B.3 External flame length and external peak pressure of pressure relief vessel 14 B.4 Recoil 15 Appendix C (Informative) Determining the aspect ratio of the protected container/silo when calculating the pressure relief area 16 C.1 Overview 16 C.2 Pressure relief at the top of cylindrical container 16 C.3 Side pressure relief of cylindrical containers 17 C.4 Top pressure relief of cylindrical container with cone 18 C.5 Side pressure relief of cylindrical container with cone (pressure relief port close to cone) 18 C.6 Side pressure relief of square container with cone 19 C.7 Pressure relief on the side of a square container with a cone (pressure relief port close to the cone) 20 C.8 Calculation of the volume of square cones and circular cones 21 C.9 Side pressure relief of square bag filter with cone (hopper) (pressure relief port close to cone) 22 Appendix D (Informative) Additional effects of container explosion pressure relief and its protection 24 D.1 Flame range 24 D.2 External influences of pressure 25 D.3 Recoil 26 D.4 Vacuum eliminator 26 Appendix E (Informative) Guide Plate 28 Appendix F (Informative) Special Considerations for Explosion Relief Design of Dust Collectors 29 F.1 External filter bag dust collector 29 F.2 Cyclone dust collector 30 Appendix G (Informative) Explosion relief design of pipelines 32 Appendix H (Informative) Bucket Elevator Explosion Pressure Relief Design 33 H.1 Design of explosion relief for bucket elevator with unknown strength 33 H.2 Double-leg square bucket elevator 33 H.3 Double-leg cylindrical bucket elevator 36 Reference 37

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1.Structure and drafting rules for standardization documents" Drafting. This document replaces GB/T 15605-2008 "Guidelines for Dust Explosion Pressure Venting". Compared with GB/T 15605-2008, in addition to structural adjustments and In addition to editorial changes, the main technical changes are as follows. --- Changed the terms "explosion pressure relief", "static opening pressure", "effective pressure relief area", "pressure relief efficiency", "pressure relief conduit", "pressure relief device" and "pressure relief" Components” and other seven terms (see 3.2, 3.5, 3.7, 3.9, 3.10, 3.12 and 3.16; 3.1, 3.2.1, 3.8, 3.9, 3.10, 3.13 and 3.14); --- Added "Dust-containing process equipment", "Controlled explosion pressure", "Maximum controlled explosion pressure", "Geometric pressure relief area", and "Theoretical pressure relief area" "Vacuum eliminator", "flameless explosion relief", "flameless explosion relief device", "fire arrester", "reference relief element" and "nominal protection 11 terms and definitions such as "volume" (see 3.1, 3.3, 3.4, 3.6, 3.8, 3.11, 3.13, 3.14, 3.15, 3.17 and 3.18); ---Deleted "dynamic opening pressure", "explosion relief pressure", "explosion relief pressure rise rate", "maximum explosion relief pressure", "maximum explosion relief pressure rise rate" rate”, “pressure relief area”, “bursting disc”, “explosion relief door”, “equivalent diameter”, “aspect ratio”, “flame length/external peak pressure”, “recoil duration” 14 terms and definitions including "time", "maximum recoil force" and "anti-explosion performance" (see 3.2.2, 3.3, 3.4, 3.5, 3.6, 3.7, 3.11, 3.12, 3.15, 3.16, 3.17, 3.18, 3.19 and 3.20); --- Added general requirements for explosion pressure relief (see 4.1); --- Added the selection of explosion relief devices (see 4.2.3); --- Added technical requirements for explosion relief devices (see 4.3); --- Changed the requirements for explosion pressure relief of containers, silos and equipment (see 4.2.1, 4.1 of the.2008 edition); --- Changed the requirements for pipeline explosion relief (see 4.2.2, 4.3 of the.2008 edition); --- Changed the basic requirements, technical documents and markings of pressure relief devices (see 4.3, Chapter 10 of the.2008 edition); --- Added "Installation, use and maintenance" to specify the requirements for the installation, use and maintenance of pressure relief devices (see Chapter 5); --- Added "Verification Method" to describe the verification method of this document (see Chapter 6); --- Deleted the explosion pressure relief in the container, silo and pipeline combination system (see 4.4 of the.2008 edition); --- Deleted the calculation method of pressure relief area of buildings (see 5.3 of the.2008 edition); --- Changed the general provisions for calculating the pressure relief area of containers (see A.1, 5.1 of the.2008 edition); --- Changed the calculation method of pressure relief area of the container (see A.2, 5.2 of the.2008 edition); --- Changed the calculation method of the area of special conveying systems (see A.3, Appendix A of the.2008 edition); --- Changed the requirements for explosion pressure relief in container, silo and pipeline combination system (see A.4, 4.4 of the.2008 edition); --- Changed the requirements for pressure relief ducts (see A.5, Chapter 7 of the.2008 edition); --- Changed the requirements for calculating the pressure relief area for heterogeneous mixtures (see A.6, Chapter 9 of the.2008 edition). Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents. This document is proposed and coordinated by the Ministry of Emergency Management of the People's Republic of China. The previous versions of this document and the documents it replaces are as follows. ---First published in.1995 as GB/T 15605-1995; first revised in.2008; ---This is the second revision. Dust explosion venting regulations

1 Scope

This document specifies the technical requirements for dust explosion pressure relief, the installation, use and maintenance requirements of explosion pressure relief devices, and describes the corresponding verification method. This document applies to explosion pressure relief of process equipment and facilities in dust explosion hazardous areas. This document is not applicable to places with coal mines, fireworks, explosives, strong oxidizers, and toxic or corrosive dust.

2 Normative references

The contents of the following documents constitute the essential clauses of this document through normative references in this document. For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to This document. GB 15577 Safety regulations for dust explosion prevention GB/T 15604 Dust explosion-proof terminology

3 Terms and definitions

The terms and definitions defined in GB/T 15604 and the following apply to this document. 3.1 Process equipment (including vessels and piping) in which combustible dust-air mixtures exist. 3.2 Explosion venting Explosion venting Pressure relief By opening the pre-designed pressure relief port, the unburned mixture and combustion products are released to prevent the pressure from rising beyond the design strength to protect the container method. 3.3 pred The pressure peak of an explosion in the protected process equipment after explosion control measures have been taken. Note. If the explosion control measure is explosion pressure relief, the controlled explosion pressure is also called explosion relief pressure. 3.4 pred,max The maximum value of the controlled explosion pressure (3.3) obtained by systematically varying the concentration of combustible dust.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB 15605-2024_English be delivered?

Answer: Upon your order, we will start to translate GB 15605-2024_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB 15605-2024_English with my colleagues?

Answer: Yes. The purchased PDF of GB 15605-2024_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB 15605-2024?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 15605-2024 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.