GB 14470.3-2011 English PDFUS$229.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB 14470.3-2011: Effluent standards of water pollutants for ammunition loading industry Status: Valid GB 14470.3: Historical versions
Basic dataStandard ID: GB 14470.3-2011 (GB14470.3-2011)Description (Translated English): Effluent standards of water pollutants for ammunition loading industry Sector / Industry: National Standard Classification of Chinese Standard: Z64 Classification of International Standard: 13.060.30 Word Count Estimation: 10,191 Date of Issue: 2011-04-29 Date of Implementation: 2012-01-01 Older Standard (superseded by this standard): GB 14470.3-2002 Quoted Standard: GB/T 6920; GB/T 7494; GB/T 11893; GB/T 11894; GB/T 11901; GB/T 11903; GB/T 11914; GB/T 13900; GB/T 16488; HJ/T 86; HJ/T 195; HJ/T 199; HJ/T 399; HJ 505; HJ 535; HJ 536; HJ 537; HJ 599; HJ 600; GJB 102A Regulation (derived from): Department of Environmental Protection Notice No. 36 of 2011 Issuing agency(ies): Ministry of Environmental Protection, General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China Summary: This Chinese standard specifies the Ammunition corporate water pollutant discharge limits, monitoring, and monitoring requirements, and standards for the implementation and supervision of the relevant provisions. This standard applies to all types of enterprises existing Ammunitions water pollutant emissions management. This standard applies to all types of Ammunitions enterprises to build the project's environmental impact assessment, environmental protection facilities design, environmental acceptance and commissioning completed water pollutant emissions management. This standard applies to legally permissible emission behavior, newly established location and sources of existing pollution sources in special protected areas management, according to"The People's Republic of China Air Pollution Prevention Law", "PRC Water Pollution Prevention Law, "marine Environmental Protection Law", "People's Republic of solid Waste Pollution prevention Law", "PRC environmental Impact Assessment Law"and other laws, regulations and rules of the relevant regulations. This standard specifies a water pollutant emission control requirements apply to companies directly or indirectly, to its discharge water pollutants outside the legal boundaries of behavior. GB 14470.3-2011: Effluent standards of water pollutants for ammunition loading industry---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Effluent stasndards of water pollutants for ammunition loading industry National Standards of People's Republic of China Replace GB 14470.3-2002 Ammunition charging industry water pollutant discharge standards Effluent standards of water pollutants for ammunition loading industry Published on.2011-04-29 2012-01-01 Implementation Ministry of Environmental Protection released State Administration of Quality Supervision, Inspection and Quarantine Ministry of Environmental Protection announcement No. 36 of.2011 To implement the "Environmental Protection Law of the People's Republic of China", "Water Pollution Prevention and Control Law of the People's Republic of China" Pollution Prevention and Control Law, prevention and control of pollution, protection and improvement of the ecological environment, and protection of human health, is now approved for the discharge of water pollutants in the ammunition charging industry The Standard is a national pollutant discharge standard and is jointly issued by the Ministry and the General Administration of Quality Supervision, Inspection and Quarantine. The standard name and number are as follows. According to relevant laws, the standard has the effect of enforcement. The standard has been implemented since January 1,.2012. From the date of implementation of the standard, the following national pollutant discharge standards are abolished. Ammunition industry water pollutant discharge standard ammunition charge (GB 14470.3-2002). Special announcement. (This announcement was signed by Ji Zhengkun of the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China) April 29,.2011 ContentForeword..iv 1 Scope..1 2 Normative references..1 3 Terms and definitions. 2 4 Water pollutant emission control requirements..3 5 Water pollutant monitoring requirements.5 6 Implementation and supervision.6 IvForewordTo implement the "Environmental Protection Law of the People's Republic of China", "Water Pollution Prevention and Control Law of the People's Republic of China" Laws and Regulations, "State Council's Decision on Implementing the Scientific Outlook on Development and Strengthening Environmental Protection", etc. Opinions on the planning of the main functional areas of the country, to protect the environment, prevent pollution, and promote the progress of the production process and pollution control technology in the ammunition charging industry, Revise this standard. This standard specifies the limits, monitoring and monitoring requirements for water pollutant discharge in the ammunition charging industry. To promote the coordinated development of the regional economy and the environment, Promote the adjustment of economic structure and the transformation of economic growth mode, and guide the development direction of industrial production technology and pollution control level. This standard Specific emission limits for water pollutants have been established. The pollutant discharge concentrations in this standard are all mass concentrations. Air pollutants and environmental noise emitted by ammunition charging enterprises shall be subject to the corresponding national pollutant discharge standards and produce solid waste. Identification, treatment and disposal of national solid waste pollution control standards. This standard was first published in.1993 and first revised in.2002. This is the second revision. The main contents of this revision are. -- The standard name was changed to “Water Pollutant Emission Standard for Ammunition Charge Industry”. -- Increased control requirements for pollutant discharge behavior in the “Scope of Application” section. - Added existing companies, new businesses, displacements, baseline displacements, direct emissions, indirect discharges in the "Terms and Definitions" section Definition of discharge, public sewage treatment system. -- Amend the "4 Technical Requirements" and "5 Other Requirements" sections of GB 14470.3-2002 to "Water Pollutant Discharge" Control requirements"; pollutant emission control project added "total phosphorus, total nitrogen, ammonia nitrogen, anionic surfactants and baseline drainage" to control Increased the number of projects from the original 9 to 14; increased the concentration limit requirements for direct and indirect emissions; increased water pollutants Emission limit. -- Amend "6 Monitoring" in GB 14470.3-2002 to "Water Pollutant Monitoring Requirements". -- Added new content in the "Implementation and Supervision" section. Since the date of implementation of this standard, the "Ammunition Industry Water Pollutant Emission Standard Ammunition Charge" (GB 14470.3-2002) is automatically abolished. This standard was formulated by the Science and Technology Standards Department of the Ministry of Environmental Protection. This standard is mainly drafted by. Beijing Zhongbing North Environmental Technology Development Co., Ltd. and China Ordnance Industry Group Corporation. This standard was approved by the Ministry of Environmental Protection on April 29,.2011. This standard has been implemented since January 1,.2012. This standard is explained by the Ministry of Environmental Protection. Ammunition charging industry water pollutant discharge standards1 Scope of applicationThis standard specifies the water pollutant discharge limit, monitoring and monitoring requirements of the ammunition charging enterprise, as well as the implementation and supervision of the standard. set. This standard applies to the management of water pollutant discharge of various types of existing ammunition charging enterprises. This standard is applicable to the environmental impact assessment, environmental protection facility design, and environmental protection inspection for all types of ammunition charging enterprises. Receive and manage the discharge of water pollutants after production. This standard applies to the discharge of pollutants permitted by law; the location of newly established sources of pollution and the existing sources of pollution in special protected areas Li, in accordance with the Law of the People's Republic of China on the Prevention and Control of Air Pollution, the Law of the People's Republic of China on the Prevention and Control of Water Pollution, Law on Environmental Protection, Law of the People's Republic of China on the Prevention and Control of Environmental Pollution by Solid Waste, Law of the People's Republic of China on Environmental Impact Assessment, etc. The relevant provisions of laws and regulations are implemented. The water pollutant discharge control requirements specified in this standard are applicable to the behavior of enterprises directly or indirectly discharging water pollutants outside their legal boundaries.2 Normative referencesThe contents of this standard refer to the following documents or their terms. For undated references, the valid version applies to this standard. quasi. GB/T 6920 Determination of water pH value - Glass electrode method GB/T 7494 - Determination of anionic surfactants - Determination of methylene blue spectrophotometric method GB/T 11893 Determination of total phosphorus in water - Ammonium molybdate spectrophotometric method GB/T 11894 Determination of total nitrogen in water - Alkaline potassium persulfate digestion - UV spectrophotometric method GB/T 11901 Determination of suspended solids by weight method GB/T 11903 Determination of water color chromaticity GB/T 11914 Determination of chemical oxygen demand in water - Potassium dichromate method GB/T 13900 Water quality black wire determination of spectrophotometry GB/T 16488 -- Determination of petroleum and animal oils HJ/T 86 Determination of Biochemical Oxygen Demand (BOD5) - Rapid Determination of Microbial Sensors HJ/T 195 Determination of ammonia nitrogen in water quality - Gas chromatography HJ/T.199 Determination of total nitrogen in water -- Gas phase molecular absorption spectroscopy HJ/T 399 Water quality chemical oxygen demand determination - Rapid digestion spectrophotometric method HJ 505 Water quality five-day biochemical oxygen demand (BOD5) determination dilution and inoculation method HJ 535 Water quality - Determination of ammonia nitrogen - Nyna reagent spectrophotometric method HJ 536 - Determination of ammonia nitrogen - Water salic acid spectrophotometric method HJ 537 Determination of water ammonia nitrogen - Distillation - Neutralization titration HJ 599 Water quality - Determination of the ladder - N-chlorohexadecyl pyridine - sodium nitrite spectrophotometric method HJ 600 Water Quality TNT, Hessian and Dien, Determination of Gas Chromatography GJB 102A Ammunition System Terminology3 Terms and definitionsThe following terms and definitions apply to this standard. 3.1 Ammunition loading ammunition loading According to the kinetic energy requirements, a certain amount of gunpowder, explosives, pyrotechnics and pyrotechnics are filled into the bomb according to certain process requirements. The process or final result in a drug-related component. 3.2 TNT 2,4,6-trinitrotoluene Common name. TNT; code. TNT; other names. brown dynamite; chemical name. 2,4,6-trinitrotoluene; molecular formula. CH3C6H2(NO2)3; relative molecular mass 227.13; structural formula. O2N N 2 CH3 NO2 3.3 Dien 2,4-dinitrotoluene Common name. Dien ladder; code. DNT; chemical name. 2,4-dinitrotoluene; molecular formula. CH3C6H3 (NO2) 2; relative points Sub-mass 182.14; structural formula. NO2 CH3 NO2 3.4 Hexagonal cyclotrimethylene trinitramine; Hexogen Common name. Hessian today; code. RDX; chemical name. cyclotrimethylene trinitramine, also known as 1,3,5-trinitro-1,3,5-triaza Cyclohexane; molecular formula. (CH2NNO2) 3; relative molecular mass 222.15; structural formula. CH2 CH2 CH2 NO2 NO2 O2N 3.5 Existing enterprise existing facility Ammunition charging enterprises or production facilities that have been approved for production or environmental impact assessment documents have been completed by the date of implementation of this standard. 3.6 New enterprise new facility The construction of ammunition and charge industry in the newly-built, rebuilt and expanded environmental impact documents approved by the implementation date of this standard. 3.7 Discharge of wastewater Refers to the amount of wastewater discharged by a production facility or enterprise outside the legal boundaries of the enterprise, including various effluxes that are directly or indirectly related to production. Waste water (including domestic sewage, cooling wastewater, plant boilers and power plant wastewater). 3.8 Datum discharge of wastewater quantity in unit time Refers to the daily cleaning equipment, working surface, washing protection products, water bath dust collector and other provisions specified for the approval of the concentration of water pollutants. The upper limit of wastewater discharge from an external drainage facility. 3.9 Direct discharge Refers to the behavior of pollutant discharge units directly discharging pollutants into environmental water bodies. 3.10 Indirect discharge Refers to the discharge of pollutants by the sewage unit to the public sewage treatment system. 3.11 Public sewage treatment system Refers to collecting waste water through sewage pipelines, providing wastewater treatment services for more than two sewage disposal units and draining can reach relevant rows Enterprises or institutions required by the standard, including urban sewage treatment plants of various scales and types, regions (all kinds of industrial parks, development zones, labor Wastewater treatment plants, etc., where the wastewater treatment plant should reach the secondary or secondary level.4 Water pollutant emission control requirements4.1 From January 1,.2012 to June 31,.2013, existing companies implement the water pollutant discharge limits specified in Table 1. Table 1 Existing enterprise water pollutant discharge limits and baseline displacement Unit. mg/L (except pH, color and baseline displacement) No. Pollutant Project Emission Limits Pollutant Emission Monitoring Location Direct Emissions Indirect Emissions 1 pH value 6~9 6~9 Corporate wastewater discharge 2 Chromaticity (dilution factor) 50 100 3 5th Biochemical Oxygen Demand (BOD5) 30 60 4 Chemical oxygen demand (CODCr) 100.200 5 total phosphorus 1.5 3.0 6 total nitrogen 30 50 7 ammonia nitrogen 20 40 8 Anionic Surfactant 2 5 9 Petroleum 5 10 10 Suspended solids (SS) 70 100 11 TNT (TNT) 1.0 1.0 Wastewater discharge port of workshop or production facility 12 DNT 1.0 1.0 13 Hessian Today (RDX) 0.5 0.5 14 Reference displacement/(m3/d) 30 The displacement measurement position is consistent with the pollutant discharge monitoring position 4.2 Since July 1,.2013, the existing enterprises have implemented the water pollutant discharge quality concentration limits specified in Table 2. 4.3 From January 1,.2012, the newly-built enterprises shall implement the water pollutant discharge quality concentration limits specified in Table 2. Table 2 Quality concentration limits and baseline displacements of new enterprises' water pollutants Unit. mg/L (except pH, color and baseline displacement) No. Pollutant Project Emission Limits Pollutant Emission Monitoring Location Direct Emissions Indirect Emissions 1 pH value 6~9 6~9 Corporate wastewater discharge 2 Chroma (dilution factor) 40 100 3 5th Biochemical Oxygen Demand (BOD5) 20 60 4 Chemical Oxygen Demand (CODCr) 60.200 5 total phosphorus 1.0 3.0 6 total nitrogen 20 50 7 ammonia nitrogen 15 40 8 Anionic Surfactant 1 5 9 Petroleum 3 10 10 Suspended solids (SS) 50 100 11 TNT 0.5 0.5 Wastewater discharge port of workshop or production facility 12 DNT 0.5 0.5 13 Hessian Today (RDX) 0.2 0.2 14 Reference displacement/(m3/d) 20 The displacement measurement position is consistent with the pollutant discharge monitoring position 4.4 According to the requirements of environmental protection work, the density of land development is high, the environmental carrying capacity begins to weaken, or the water environment capacity is small. In areas where the ecological environment is fragile and prone to serious water pollution problems and special protection measures are required, the pollution of facilities should be strictly controlled. Emissions behavior, the enterprises in the above regions implement the special discharge limits for water pollutants specified in Table 3. The geographical scope and time for the implementation of special discharge limits for water pollutants shall be governed by the environmental protection administrative department of the State Council or the provincial people's government. set. Table 3 Special discharge limits for water pollutants and baseline displacement Unit. mg/L (except pH, color and baseline displacement) No. Pollutant Project Emission Limits Pollutant Emission Monitoring Location Direct Emissions Indirect Emissions 1 pH value 6~9 6~9 Corporate wastewater discharge 2 Chromaticity (dilution factor) 30 40 3 5th Biochemical Oxygen Demand (BOD5) 20 40 4 Chemical Oxygen Demand (CODCr) 50 60 5 total phosphorus 0.5 1.0 6 total nitrogen 15 20 7 ammonia nitrogen 10 15 8 Anionic Surfactant 0.5 1 9 Petroleum 2 3 10 Suspension (SS) 30 50 11 TNT (TNT) 0.2 0.2 Wastewater discharge port of workshop or production facility 12 DNT (DNT) 0.2 0.2 13 Hessian Today (RDX) 0.1 0.1 14 Reference displacement/(m3/d) 20 The displacement measurement position is consistent with the pollutant discharge monitoring position 4.5 The water pollutant discharge limit is applicable to the case where the actual discharge of the daily effluent wastewater specified in this standard is not higher than the reference discharge. If If the actual daily discharge exceeds the baseline displacement, the measured water pollutant mass concentration shall be converted into the water pollutant reference water volume according to formula (1). The mass concentration is discharged, and the water concentration of the water pollutant is used as the basis for determining whether the emission is up to standard. Ρρ = total solid base (1) Where. ρ base--water pollutant reference water discharge mass concentration, mg/L; Q total - total drainage, m3/d; Q base - baseline displacement, m3/d; ρ实--Measured mass concentration of water pollutants, mg/L.5 Water pollutant monitoring requirements5.1 Sampling of wastewater discharged by enterprises shall be carried out according to the type of pollutants to be monitored and at the monitoring location of the specified pollutant discharge. Waste water Facilities should be monitored after the facility. The enterprise shall set the sampling port according to the requirements of the national technical regulations on pollution source monitoring, in the pollutant discharge A permanent drain outlet sign shall be provided for the monitoring position. 5.2 Requirements for the installation of automatic monitoring equipment for pollutant discharge in newly-built enterprises and existing enterprises, in accordance with relevant laws and “Automatic Monitoring and Management of Pollution Sources” The provisions of the Measures are implemented. 5.3 The frequency, sampling time, quality assurance and quality control requirements for monitoring the discharge of water pollutants of enterprises shall be in accordance with the requirements of the State. The provisions of the technical specifications for monitoring pollution sources and the requirements of the environmental protection administrative department shall be implemented. 5.4 The enterprise shall monitor the discharge status according to the relevant laws and the “Measures for the Administration of Environmental Monitoring” and maintain the original monitoring records. 5.5 The determination of the quality concentration of pollutants discharged from enterprises shall be based on the method standards listed in Table 4. Table 4 Standards for determination of mass concentration of water pollutants No. Contaminant Project Method Standard Name Method Standard Number 1 pH value water quality determination of glass electrode method GB/T 6920-1986 2 Determination of chromaticity of water quality - Dilution multiple method GB/T 11903-1989 Five-day biochemical oxygen demand (BOD5) Water quality five-day biochemical oxygen demand (BOD5) determination dilution and inoculation method HJ 505-2009 Determination of Biochemical Oxygen Demand (BOD) of Water Quality Microbial Sensor Rapid Assay HJ/T 86-2002 Cod (CODCr) Water quality - Determination of chemical oxygen demand - Dichromate method GB/T 11914-1989 Water quality chemical oxygen demand determination - Rapid digestion spectrophotometric method HJ/T 399-2007 5 Total phosphorus phosphorus - Determination of total phosphorus - Ammonium molybdate spectrophotometric method GB/T 11894-1989 6 Determination of total nitrogen in total nitrogen - Alkaline potassium persulfate digestion - UV spectrophotometric method GB/T 11894-1989 Determination of total nitrogen in water quality Gas-phase molecular absorption spectroscopy method HJ/T.199-20057 ammonia nitrogenDetermination of ammonia nitrogen in water quality - Nachite reagent spectrophotometric method HJ 535-2009 Water quality - Determination of ammonia......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB 14470.3-2011_English be delivered?Answer: Upon your order, we will start to translate GB 14470.3-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB 14470.3-2011_English with my colleagues?Answer: Yes. The purchased PDF of GB 14470.3-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB 14470.3-2011?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 14470.3-2011 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |