Home   Cart   Quotation   Policy   About-Us
www.ChineseStandard.net
SEARCH

CJ/T 113-2015 English PDF

US$1179.00 · In stock
Delivery: <= 8 days. True-PDF full-copy in English will be manually translated and delivered via email.
CJ/T 113-2015: Gas Bred space heater
Status: Valid

CJ/T 113: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
CJ/T 113-20151179 Add to Cart 8 days Gas Bred space heater Valid
CJ/T 113-2000919 Add to Cart 6 days Gas-fired space heaters for domestic use Obsolete

Similar standards

GB/T 13611   CJ/T 393   GB/T 16411   CJ/T 513   CJ/T 199   CJ/T 157   

Basic data

Standard ID: CJ/T 113-2015 (CJ/T113-2015)
Description (Translated English): Gas Bred space heater
Sector / Industry: Urban Construction Industry Standard (Recommended)
Classification of Chinese Standard: P45
Classification of International Standard: 91.14
Word Count Estimation: 51,576
Date of Issue: 2015-01-20
Date of Implementation: 2015-07-01
Older Standard (superseded by this standard): CJ/T 113-2000
Quoted Standard: GB/T 191; GB/T 2828.1; GB 4706.1-2005; GB/T 5013.1; GB/T 5023.1; GB 6932-2001; GB/T 7306.1; GB/T 7306.2; GB/T 7307; GB/T 12113-2003; GB/T 13611; GB 14536.6-2008; GB/T 16411-2008; GB 25034-2010; GB 27790; CJ/T 30; CJ/T 180; CJ/T 346; CJ/T 393; CJ/T 421-2013; CJ/T 447-2014; JB/T 6411; JB/T 7221
Regulation (derived from): Ministry of Housing and Urban-Rural Development Notice 711
Issuing agency(ies): Ministry of Housing and Urban-Rural Development of the People's Republic of China
Summary: This Standard specifies the terms and definitions gas heater, classification and models, structures and materials, requirements, test methods, inspection regulations side, logos and brochures, packaging, transportation and storage. This Standard applies to the use of GB/T13611 predetermined gas heater, comprising: a) rated thermal input of not more than 20kW of home heating. b) single burner heat input rating of not more than 120kW of non-domestic heater. This Standard does not apply to outdoor use heaters, condensing heaters, specially designed for industrial use heaters, heater for use in a moving vehicle in transport.

CJ/T 113-2015: Gas Bred space heater

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS91.140 P45 People's Republic of China town construction industry standards Replacing CJ/T 113-2000 Gas heater 2015-01-20 release 2015-07-01 implementation People's Republic of China Ministry of Housing and Urban - Rural Development Directory Preface III 1 Scope 1 2 normative reference document 1 3 Terms and definitions 2 Classification and Model 3 4.1 Classification 3 4.2 Model 4 5 structure and material 4 5.1 Structure 4 5.2 Materials 9 6 requirements 9 6.1 Stability 9 6.2 Main burner temperature resistance 9 6.3 Airway air tightness 9 6.4 Heat input accuracy 10 6.5 Combustion conditions 10 6.6 Ignition burner 10 6.7 Heating element outer surface 10 6.8 Safety device 10 6.9 Exhaust hood for flue heater 11 6.10 Airflow interference with flue heater without exhaust hood 12 6.11 Efficiency 12 6.12 convection heater 12 6.13 temperature rise 12 6.14 Electrical safety 13 6.15 NOx contamination of non-linear heating devices 13 6.16 Continuous operation safety 13 7 Test methods 13 7.1 Test conditions 13 7.2 Stability 13 7.3 Main burner temperature resistance 14 7.4 Gas passage air tightness 14 7.5 Heat input accuracy 14 7.6 Combustion conditions 14 7.7 Ignition burner 15 7.8 Heating element outer surface 15 7.9 Safety device 15 7.10 Exhaust hood for flue heater 17 7.11 Airflow interference with flue heater without exhaust hood 17 7.12 Efficiency 18 7.13 convection heater 21 7.14 Temperature rise 26 7.15 Continuous operation safety

8 inspection rules

8.1 Factory inspection 27 8.2 Sampling Inspection 27 8.3 Type Inspection 27 8.4 Unqualified Classification of Inspection Items

9 logo and instructions

9.1 logo 28 9.2 Manual 29 Packaging, transportation and storage 10.1 Packaging 30 10.2 Transport 30 10.3 Storage 30 Appendix A (informative) Schematic diagram of heater structure --- Classification by smoke method 31 Appendix B (Normative Appendix) Electrical Safety 33 Appendix C (informative) NOx contamination of non - linear heaters 39 Appendix D (informative) Radiation correction factor for water and CO2 Appendix E (informative) This standard supports the terms and conditions of GB 16914-2012. Reference 46

Foreword

This standard is drafted in accordance with the rules given in GB/T 1.1-2009. This standard replaces CJ/T 113-2000 "Household Gas Heater". This standard is the CJ/T 113-2000 "home gas heater" revision, compared with the CJ/T 113-2000 main technical changes as follows. --- Added non-domestic heaters (see Chapter 1); - modified the classification method (see Chapter 4, Chapter 4 of Chapter 4); - modified the thermal efficiency of non-radiative heaters (see Table 6 of 6.11,.2000); - Added thermal efficiency test method for radiant heaters (see Table 6 of 6.12,.2000). This standard is consistent with GB 16914-2012 "Safety Conditions for Gas Burners" and is given in Appendix E. Subject to the requirements of GB 16914-2012 basic requirements. This standard is proposed by the Institute of Standards and Valuation of the Ministry of Housing and Urban-Rural Development. This standard by the Ministry of Housing and Urban and Rural Development Standardization Technical Committee. The drafting of the standard units. the State Gas Equipment Quality Supervision and Inspection Center, Shanghai Top State Electronics Co., Ltd., Tongji University, Qingdao Sen Ruipu Heat Co., Ltd., Zhongshan Kaiwo to HVAC Co., Ltd., Shanghai Connaught Universal Equipment Manufacturing Co., Ltd., Shandong Gerui blue heat set Co., Ltd., Beijing Landed Energy Technology Co., Ltd., West Gas Control System Manufacturing (Suzhou) Co., Ltd., Shi Wanke HVAC Technology Jin) Co., Ltd., Shaanxi Hongyuan Gas Equipment Co., Ltd., China Municipal Engineering North China Design Research Institute Co., Ltd. The main drafters of this standard. Long Fei, Zhang Jianhai, Lu Weidong, Qin Zhaokui, Liu Chunxia, Tian Jun, Zhang Jin Ge, Zhang Linyuan, Yan Linpu, Zhang Ma, Zhu Hong Ye, Sun Zonghao, Hu Yu. This standard replaced the previous version of the standard release. --- CJ/T 113-2000. Gas heater

1 Scope

This standard specifies the terms and definitions of gas heaters (hereinafter referred to as heaters), classification and type, structure and materials, requirements, test Law, inspection rules, logos and instructions, packaging, transportation and storage. This standard applies to the use of GB/T 13611 provisions of the gas heater, including. a) rated heat input is not greater than 20kW of household heaters; b) Non-domestic heaters with a single burner rated heat input of not more than 120 kW. This standard does not apply to the use of outdoor heating, condensing heater, designed for industrial use of the heater, in the transport of transport The heater used in the tool.

2 normative reference documents

The following documents are indispensable for the application of this document. For dated references, the only dated edition applies to this article The latest version (including all modifications) applies to this document. GB/T 191 packaging and storage icon GB/T 2828.1 Sampling inspection procedures Part 1. Batch inspection sampling plan for retrieval by quality limit (AQL) Safety of household and similar electrical appliances - Part 1. General requirements GB 4706.1-2005 GB/T 5013.1 Rubber insulated cables of rated voltages up to and including 450/750 V - Part 1. General requirements GB/T 5023.1 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 1. General requirements Household gas fast water heaters GB 6932-2001 GB/T 7306 (all parts) 55 ° sealed tube thread GB/T 7307 55 ° unsealed pipe thread Methods of measurement for contact current and protective conductor currents GB/T 12113-2003 GB/T 13611 Urban Gas Classification and Basic Characteristics GB 14536.6-2008 Particular requirements for automatic control systems for burners for household and similar electrical automatic controllers General test methods for household gas appliances GB/T 16411-2008 GB 25034-2010 Gas Heating Water Heater Urban Gas Pressure Regulators GB 27790 CJ/T 30 thermoelectric gas appliance flame protection device CJ/T 180 Manual gas valves for construction CJ/T 346 household gas appliance automatic shut - off valve CJ/T 393 household gas appliance plug valve assembly Electronic Controllers for Household Gas Burners CJ/T 447-2014 Pipeline Gas Self - closing Valve JB/T 6411 HVAC, air conditioning with axial fan JB/T 7221 unit air conditioning unit with double inlet centrifugal fan
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of CJ/T 113-2015_English be delivered?

Answer: Upon your order, we will start to translate CJ/T 113-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 5 ~ 8 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of CJ/T 113-2015_English with my colleagues?

Answer: Yes. The purchased PDF of CJ/T 113-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version CJ/T 113-2015?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version CJ/T 113-2015 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.