Summary: This standard is applicable to unit air conditioners that use motor-driven compressors, indoor units with a static pressure of 0 Pa (gauge pressure), unit air conditioners for computer and data processing equipment rooms, unit air conditioners for communication base stations, and constant temperature Wet unit air conditioner. Not applicable to multi-unit air conditioning (heat pump) units, rooftop air conditioning units and air duct supply air conditioning (heat pump) units.

CEL004-2020: Implementation rules for energy efficiency labeling of unit air conditioners

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
CEL004-2020 Implementation rules for energy efficiency labeling of unit air conditioners Replace CE L 004-2016 Implementation rules for energy efficiency labeling of unit air conditioners 1 General 1.1 These rules are formulated in accordance with the "Energy Efficiency Label Management Measures" (hereinafter referred to as "Measures"). 1.2 This rule applies to the use of motors to drive compressors, the indoor unit static pressure is 0 Pa (gauge pressure Power) unit air conditioner, computer and data processing room with unit air conditioner Unit air conditioner for power saving and communication base station and unit air conditioner with constant temperature and humidity Use, filing and announcement of the energy efficiency label (hereinafter referred to as the logo) of the machine (hereinafter referred to as the air conditioner). Not applicable to multi-unit air conditioning (heat pump) units, rooftop air conditioning units and wind Tube air-conditioning (heat pump) unit.

2 Logo style and specifications

2.1 The logo is a blue and white background color logo with a length of 109 mm and a width of 66 mm. 2.2 The name of the label is. China Energy Efficiency Label (English name is CHINA ENERGY LABEL), air-cooled single-cooled unit air conditioner includes the following. (1) The name (or abbreviation) of the producer; (2) Specifications and models; (3) Energy efficiency rating; (4) Energy efficiency ratio in cooling season [(W · h)/(W · h)]; (5) Cooling capacity (W); (6) Power consumption during cooling season (kW · h); (7) The mandatory national standard number for energy efficiency; (8) Energy efficiency information code; (9) Energy efficiency "leader" information (only for products included in the national energy efficiency "leader" catalog). Air-cooled heat pump unit air conditioners include the following. (1) The name (or abbreviation) of the producer; (2) Specifications and models; (3) Energy efficiency rating; (4) Annual performance coefficient [(W · h)/(W · h)]; (5) Cooling capacity (W); (6) Heating capacity (W); (7) Power consumption during cooling season (kW · h); (8) Power consumption during heating season (kW · h); (9) The mandatory national standard number of energy efficiency; (10) Energy efficiency information code; (11) Energy efficiency "leader" information (only for products included in the national energy efficiency "leader" catalog). Water-cooled unit air conditioners include the following. (1) The name (or abbreviation) of the producer; (2) Specifications and models; (3) Energy efficiency rating; (4) Refrigeration integrated partial load performance coefficient (W/W); (5) Cooling capacity (W); (6) Refrigeration power consumption (W); (7) The mandatory national standard number for energy efficiency; (8) Energy efficiency information code; (9) Energy efficiency "leader" information (only for products included in the national energy efficiency "leader" catalog). Unit air conditioners for computer and data processing equipment rooms include the following. (1) The name (or abbreviation) of the producer; (2) Specifications and models; (3) Energy efficiency rating; (4) Annual energy efficiency ratio (W/W); (5) Cooling capacity (W); (6) Refrigeration power consumption (W); (7) Type. air-cooled/water-cooled/glycol economically-cooled/air-cooled dual-cooled source/water-cooled dual-cooled source; (8) The mandatory national standard number of energy efficiency; (9) Energy efficiency information code; (10) Energy efficiency "leader" information (only for products included in the national energy efficiency "leader" catalog). Unit air conditioners for communication base stations include the following. (1) The name (or abbreviation) of the producer; (2) Specifications and models; (3) Energy efficiency rating; (4) Refrigeration energy efficiency ratio (W/W); (5) Cooling capacity (W); (6) Refrigeration power consumption (W); (7) The mandatory national standard number for energy efficiency; (8) Energy efficiency information code; (9) Energy efficiency "leader" information (only for products included in the national energy efficiency "leader" catalog). Constant temperature and humidity unit air conditioners include the following. (1) The name (or abbreviation) of the producer; (2) Specifications and models; (3) Energy efficiency rating; (4) Annual energy efficiency ratio (W/W); (5) Cooling capacity (W); (6) Refrigeration power consumption (W); (7) The mandatory national standard number for energy efficiency; (8) Energy efficiency information code; (9) Energy efficiency "leader" information (only for products included in the national energy efficiency "leader" catalog). 2.3 An example of the logo style is shown in Annex 1, which can be downloaded from the "China Energy Efficiency Label Network".

3 Energy efficiency testing

3.1 Annual performance coefficient, energy efficiency ratio during cooling season, performance coefficient of integrated cooling partial load, Annual energy efficiency ratio, cooling energy efficiency ratio, cooling capacity, cooling power consumption, power consumption during cooling season Quantity, energy efficiency ratio in heating season, heating capacity, heating power consumption, heating season power consumption, The testing methods of the parameters related to the energy efficiency performance of products such as the electric auxiliary heating control function should be based on According to the currently valid version of GB 19576. 3.2 "Unit Air Conditioner Energy Efficiency Test Report" (hereinafter referred to as the test report) See Annex 2 for the format. 3.3 Producers or importers can use their own testing laboratories, or entrust them to obtain according to law Qualified third-party inspection and testing institutions to test products, and according to energy efficiency Rate mandatory national standards to determine product energy efficiency grades. Producers or importers who use their own testing laboratories to determine energy efficiency grades should ensure that Prove that its testing laboratory has the ability to perform testing in accordance with the mandatory national standards for energy efficiency And encourage them to obtain the approval of national accreditation bodies. 3.4 Those who use their own testing laboratory for testing should provide a laboratory testing capability certificate Ming materials (including laboratory personnel capabilities, equipment capabilities and testing management specifications) have been If it is approved by a national accreditation body, it should also provide a copy of the corresponding accreditation certificate; use If a third-party inspection and testing agency conducts testing, it shall provide the qualification certification of the inspection and testing agency Copy of the final certificate. Authorized institutions should be responsible for the energy efficiency labels and product energy efficiency used by producers and importers. Check the inspection report.

4 Identification of identification information

4.1 Producer refers to the owner or user of a product brand that is legally responsible for product quality. 4.2 The specification and model should be consistent with the label on the nameplate. 4.3 Energy efficiency rating, year-round performance coefficient, energy efficiency ratio during cooling season, negative for comprehensive cooling Charge performance coefficient, annual energy efficiency ratio, cooling energy efficiency ratio, cooling capacity, cooling power consumption, Power consumption during cooling season, energy efficiency ratio during heating season, heating capacity, heating power consumption, heating Seasonal power consumption, electric auxiliary heating control functions and other energy efficiency performance related parameters should be based on Determined according to the currently valid version and test report of GB 19576. The full mark of the energy efficiency label Coefficient of annual performance, energy efficiency ratio during cooling season, coefficient of performance of comprehensive load of cooling, annual The energy efficiency ratio and cooling energy efficiency ratio should not exceed the value range of the corresponding energy efficiency level. 4.4 The mandatory national standard for energy efficiency refers to the currently valid version of GB 19576. 4.5 The producer or importer directly generates the product energy efficiency information code from the energy efficiency label information system when filing. 4.6 Products listed in the national energy efficiency "leader" catalog should be marked with energy efficiency "leader" information. 5 Printing, applying and displaying the logo 5.1 Every air conditioner (set) shipped or imported shall be marked. 5.2 The producer or importer prints its own logo and is responsible for the quality of the print. 5.3 The logo shall be printed on coated paper of 80 grams and above. 5.4 The label should be applied on the obvious part of the front of the air-conditioning indoor unit and on the product packaging Or explain in the instruction manual. If the products are traded through online commodities, The product information display main page displays the corresponding logo in a prominent position. 5.5 The logo applied to the air conditioner should comply with the provisions of Article 2 Words and colors cannot be changed. Marking specifications can be based on the provisions of Article 2.1 of this rule Zoom in on the scale. 5.6 The main page of product packaging, instruction manuals, and online trading product information display The energy efficiency label used in the publicity can be enlarged or reduced in proportion, and the paper version can be single Color printing, the text in the logo should be legible. 5.7 The products listed in the national energy efficiency "leader" catalogue are shipped out 30 days after the catalogue is published. Products should use energy efficiency labels that contain information on the "leader" of energy efficiency.

6 Filing of the logo

6.1 The producer or importer shall file one by one according to the product specifications and models. Different models However, the refrigeration system is the same, the structure is the same, the annual performance coefficient, the energy efficiency ratio during the cooling season, and the The products with the same performance coefficient of cold comprehensive partial load, annual energy efficiency ratio, and refrigeration energy efficiency ratio are in It is no longer necessary to submit a test report when filing. 6.2 The producer and importer should apply to the authorized institution for filing, and at the same time "Effective Marking Network" fill in the "Energy Efficiency Marking Record Form of Unit Air Conditioner" (See Annex 3) and other relevant filing materials as stipulated in the Measures. The record materials should be true, accurate and complete. 6.3 When the content of the product logo changes, it shall be filed with the authorized institution again. 6.4 For those who do not meet the requirements of Article 6.2 of this rule, the authorized institution shall notify the producer or The exporter promptly added materials or replaced the used logo. 6.5 Materials in foreign languages shall be accompanied by Chinese translations, and the Chinese text shall prevail.

7 Logo announcement

7.1 The authorized institution shall verify and revoke the Relevant filing information and timely announcement. 7.2 The authorized institution shall establish a product information database Departments, etc. provide product information query services, timely verify and announce the verification and supervision of logos Inspection.
......

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of CEL 004-2020_English be delivered?

Answer: Upon your order, we will start to translate CEL 004-2020_English as soon as possible, and keep you informed of the progress. The lead time is typically in 9 seconds (download/delivered in 9 seconds). The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of CEL 004-2020_English with my colleagues?

Answer: Yes. The purchased PDF of CEL 004-2020_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.