HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (7 Jun 2025)

PDF GB 30254-2024 English (GB 30254-2013: Older version)


Search result: GB 30254-2024 (GB 30254-2013 Older version)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB 30254-2024English260 Add to Cart 0-9 seconds. Auto-delivery. Minimum allowable values of energy efficiency and energy efficiency grades for cage three-phase high voltage induction motor Valid
GB 30254-2013English190 Add to Cart 0-9 seconds. Auto-delivery. Minimum allowable values of energy efficiency and the energy efficiency grades for cage three-phase high voltage induction motor Valid

PDF Preview: GB 30254-2024                   PDF Preview: GB 30254-2013
            

GB 30254-2024: PDF in English

GB 30254-2024 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 27.010 CCS F 01 Replacing GB 30254-2013 Minimum Allowable Values of Energy Efficiency and Energy Efficiency Grades for Cage Three-Phase High Voltage Induction Motor ISSUED ON: AUGUST 23, 2024 IMPLEMENTED ON: SEPTEMBER 1, 2025 Issued by: State Administration for Market Regulation; Standardization Administration of the People’s Republic of China. Table of Contents Foreword ... 3 1 Scope ... 5 2 Normative References ... 5 3 Terms and Definitions ... 6 4 Energy Efficiency Grades ... 6 5 Technical Requirements ... 6 6 Test Methods ... 6 Foreword This Document was drafted as per the rules specified in GB/T 1.1-2020 Directives for Standardization – Part 1: Rules for the Structure and Drafting of Standardizing Documents. This Document replaced GB 30254-2013 Minimum Allowable Values of Energy Efficiency and the Energy Efficiency Grades for Cage Three-phase High Voltage Induction Motor. Compared with GB 30254-2013, the major technical changes of this Document are as follows besides the structural adjustments and editorial modifications: a) Change the scope of the standard (see Clause 1 of this Edition; Clause 1 of the 2013 Edition); b) Delete the energy-saving evaluation value of cage three-phase high voltage induction motors (see 3.2 of the 2013 Edition); c) Add the requirements for the energy efficiency limit value of motors (see 5.2 of this Edition; 4.3 of the 2013 Edition); d) Delete the requirements for the energy-saving evaluation value of motors (see 4.4 of the 2013 Edition); e) Change the range of application of the test method for rated power (see Clause 6 of this Edition; Clause 5 of the 2013 Edition); f) Add the energy efficiency rating indicators of cage three-phase high voltage induction motors with 2 poles (rated power 3,550 kW~10,000 kW) under 3 kV (3.3 kV) and 6 kV voltage IC01, IC11, IC21, IC31, IC81W cooling methods (see Table 1 of this Edition; Table 1 of the 2013 Edition); g) Add energy efficiency rating indicators for cage three-phase high voltage induction motors with 2 poles (rated power 2,500 kW~10,000 kW) under 10 kV voltage IC01, IC11, IC21, IC31, IC81W cooling methods (see Table 2 of this Edition; Table 2 of the 2013 Edition); h) Add energy efficiency rating indicators for cage three-phase high voltage induction motors with 2 poles (rated power 2,800 kW~10,000 kW), 4 poles (rated power 2,500 kW~10,000 kW), 6 poles (rated power 1,800 kW~8,000 kW), and 8 poles (rated power 1,400 kW~6,300 kW) , 10 poles (rated power 1,250 kW~5,000 kW), 12 poles (rated power 900 kW~4,000 kW) under 3 kV (3.3 kV) and 6 kV voltage IC611, IC616, IC511, IC516 cooling methods (see Table 3 of this Edition; Table 3 of the 2013 Edition); i) Added energy efficiency rating indicators for cage three-phase high voltage induction motors under 10 kV voltage IC611, IC616, IC511, and IC516 cooling methods (see Table 4 of this Edition); Minimum Allowable Values of Energy Efficiency and Energy Efficiency Grades for Cage Three-Phase High Voltage Induction Motor 1 Scope This document specifies the energy efficiency level, technical requirements and test methods of high-voltage three-phase cage-type asynchronous motors (hereinafter referred to as "motors"). This document is applicable to 50 Hz three-phase AC power supply, continuous working vertical, horizontal motors and explosion-proof motors, with 2 poles to 12 poles, voltage, cooling method, rated power range as follows: a) Under 3 kV (3.3 kV) and 6 kV voltage, IC01, IC11, IC21, IC31, IC81W cooling method, rated power is 200 kW to 25,000 kW; b) Under 10 kV voltage, IC01, IC11, IC21, IC31, IC81W cooling method, rated power is 200 kW to 22,400 kW; c) Under 3 kV (3.3 kV) and 6 kV voltage, IC611, IC616, IC511, IC516 cooling method, rated power is 200 kW to 10,000 kW; d) Under 10 kV voltage, IC611, IC616, IC511, IC516 cooling method, rated power is 200 kW~10,000 kW; e) Under 3 kV (3.3 kV) and 6 kV voltage, IC411 cooling method, rated power is 200 kW~3,150 kW; f) Under 10 kV voltage, IC411 cooling method, rated power is 200 kW~2,800 kW. 2 Normative References The provisions in following documents become the essential provisions of this Document through reference in this Document. For the dated documents, only the versions with the dates indicated are applicable to this Document; for the undated documents, only the latest version (including all the amendments) is applicable to this Document. GB/T 755 Rotating electrical machines - Rating and performance GB/T 1032-2023 Test methods of three-phase induction motors 3 Terms and Definitions For the purposes of this Document, the following terms and definitions apply. 3.1 Minimum allowable values of energy efficiency for cage three-phase high voltage induction motor Under specified test conditions, the lowest standard value of the efficiency of cage three-phase high-voltage induction motors is allowed. 4 Energy Efficiency Grades The energy efficiency grade of motors is divided into 3 grades, among which Grade-1 has the highest energy efficiency. The measured efficiency of motors of each grade at rated output power shall be no lower than the requirements of Tables 1 to 6, and the tolerance shall comply with the provisions of GB/T 755. Within the specified range, the efficiency of motors whose rated power values are not listed in the table is determined by linear interpolation. 5 Technical Requirements The requirements for energy efficiency limit values of motors are as follows: a) The measured efficiency of motors under 3 kV (3.3 kV) and 6 kV, 10 kV voltages and IC01, IC11, IC21, IC31, IC81W cooling methods at rated output power shall be no lower than the provisions of Grade-3 in Tables 1 and 2; b) The measured efficiency of motors under 3 kV (3.3 kV) and 6 kV, 10 kV voltages and IC611, IC616, IC511, IC516 cooling methods at rated output power shall be no lower than the requirements of Grade-3 in Tables 3 and 4; c) The measured efficiency of motors under 3 kV (3.3 kV) and 6 kV, 10 kV voltages and IC411 cooling methods at rated output power shall be no lower than the requirements of Grade-3 in Tables 5 and 6. 6 Test Methods For motors with a rated power of 2,000 kW or less, the power loss shall be determined according to the Method-B (loss analysis method for measuring input and output power) specified in 12.3 of GB/T 1032-2023. For motors with a rated power of more than 2,000 kW, the power loss shall ......
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.