GBZ20996.2-2007 English PDF
Basic dataStandard ID: GB/Z 20996.2-2007 (GB/Z20996.2-2007)Description (Translated English): Performance of high-voltage direct current (HVDC) systems -- Part 2: Faults and switching Sector / Industry: National Standard Classification of Chinese Standard: K46 Classification of International Standard: 29.200; 29.240.99 Word Count Estimation: 43,480 Date of Issue: 2007-06-21 Date of Implementation: 2/1/2008 Adopted Standard: IEC/TR 60919-2-1991, IDT Regulation (derived from): ?National Standard Announcement 2007 No.6 (Total No.106) (National-Standard-Commission) Issuing agency(ies): Ministry of Health of the People's Republic of China Summary: This standard specifies the HVDC system transient performance and fault protection requirements. Discusses the three-phase bridge (dual) joins the 12-pulse (move) change ends of HVDC system failures and transient performance flow unit composed of operation. HVDC system does not involve many-fold, but the ends of the parallel system is included in the inverter and parallel lines are discussed. Assume inverter thyristor valve as a bridge arm, using metal oxide surge arresters without gaps with insulation, and power can be bi-directional transmission. This section does not consider the diode valve. GB/Z 20996 consists of three parts. Steady Part 1, Part 2 failures and operational, Part 3 dynamic. In the formulation and preparation process has three parts to avoid a repeat. Therefore, when the user intends to develop HVDC ends specifications, the entire contents of the three reference parts. The various components of the system, should pay attention to the difference between the system and equipment design and performance specifications between norms. This section does not provide equipment specifications and test requirements. But rather focuses on the technical requirements that affect system performance. This section also does not include detailed seismic performance requirements. In addition, different HVDC systems may exist many differences, there is no discussion in this section of this detail, therefore, this section should not be used directly as the technical specifications for a specific project. However, you can take this as a basis for the preparation of a specific transmission system to meet the technical specifications required by the actual system. Content in this section is no distinction between the user and the manufacturer's responsibility. GBZ20996.2-2007: Performance of high-voltage direct current (HVDC) systems -- Part 2: Faults and switching---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. GB /Z 20996.2-2007 Performance of high-voltage direct current (HVDC) systems.Part 2. Faults and switching ICS 29.200; 29.240.99 K46 National Standardization Technical Document of the People's Republic of China GB /Z20996.2-2007/IEC /TR60919-2.1991 High-voltage DC system performance Part 2. Faults and operations (IEC /T R60919-2..1991, IDT) Released on.2007-06-21 General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China China National Standardization Administration issued ContentForeword I Introduction II 1 General 1 2 High-voltage DC transient performance technical specification overview 1 3 Transient process with no fault operation 2 4 AC system failure 5 5 AC filter, reactive power equipment and AC bus fault 8 6 Inverter unit failure 10 7 DC reactor, DC filter and other DC equipment faults 13 8 DC line fault 15 9 grounding line fault 18 10 metal return line fault 18 11 Insulation coordination of high voltage DC system 20 12 Communication requirements 23 13 auxiliary system 24 Appendix A (informative) (information) bibliography 38 GB /Z20996.2-2007/IEC /TR60919-2.1991ForewordGB /Z20996 "Performance of HVDC System" is a national standardization technical document, which includes the following three parts. Part 1. Steady state; Part 2. Faults and operations; Part 3. Dynamic. This part is the second part, equivalent to the use of IEC /T R60919-2.1991 "High-voltage DC system performance Part 2. Faults and operations Do it. The editing format is in accordance with China's national standard GB/T 1.1-2000. This part was proposed by China Electrical Equipment Industry Association. This part is under the jurisdiction of the National Power Electronics Standardization Technical Committee (SAC/TC60). This section is responsible for drafting units. China Electric Power Research Institute, Xi'an High Voltage Electric Apparatus Research Institute. Participated in the drafting of this section. Xi'an Power Electronics Technology Research Institute, Beijing Netlink DC Transmission Engineering Technology Co., Ltd., Xi'an Xidian Power Rectifier Co., Ltd., China Southern Power Grid Technology Research Center, Beijing Institute of Electrical Technology and Economics, Machinery Industry. The main drafters of this section. Zeng Nanchao, Qi Ruifeng, Zhou Guanyun, Nie Dingzhen, Ma Zhenjun, Huang Ying, Wang Mingxin, Cheng Xiaotong, Wei Hongqi, Fang Xiaoyan, Tao Yu, Zhao Yujun, Tian Fang. This guidance document is the first release. This guidance technical document is interpreted by the National Power Electronics Standardization Technical Committee. GB /Z20996.2-2007/IEC /TR60919-2.1991IntroductionIn the construction of China's power grid, high-voltage direct current transmission has a very broad development prospect for long-distance power transmission and large-area networking. An important means to solve high voltage, large capacity, long distance power transmission and asynchronous networking. According to the actual needs of China's DC transmission project and high voltage straight The development of the trend of the power transmission technology is based on the digestion and absorption of imported technologies, the construction experience of domestic DC transmission projects and the independent development of equipment. On the basis of research, the national standard system for high-voltage direct current transmission equipment is formulated. Content includes basic standards, main equipment standards, and control and protection equipment standard. The project has completed or is in the process of developing a total of 19 national standards. (1) "The first part of the performance of the high-voltage DC system" (2) "The second part of the performance and performance of the high-voltage DC system" (3) "The third part of the performance of high-voltage DC system" (4) "Insulation coordination procedure for HVDC converter station" (5) "Determination of loss of high-voltage DC converter station" (6) "Conversion transformer for the second part of high-voltage direct current transmission" (7) Technical parameters and requirements for oil-immersed converter transformers for HVDC transmission (8) "Oil-immersed smoothing reactor for HVDC transmission" (9) Technical parameters and requirements for oil-immersed smoothing reactors for HVDC transmission (10) "Guidelines for Non-Gap Metal Oxide Arresters for HVDC Converter Stations" (11) "Parallel capacitors and AC filter capacitors for HVDC transmission" (12) "DC Filter Capacitor for HVDC Power Transmission" (13) "General requirements for ordinary thyristors for HVDC transmission" (14) "Test of Thyristor Valves for Power and Electronic Technology Static Reactive Power Compensation Devices of Transmission and Distribution Systems" (15) "HVDC power transmission system control and protection equipment" (16) "High-voltage DC converter station noise" (17) "High-voltage DC bushing technical performance and test methods" (18) "General Requirements for Photo-Controlled Thyristors for HVDC Transmission" (19) "Guidelines for DC System Research and Equipment" GB /Z20996.2-2007/IEC /TR60919-2.1991 High-voltage DC system performance Part 2. Faults and operations1 General1.1 Scope This part of GB /Z20996 is a guiding technical document on the transient performance and fault protection requirements of high voltage DC systems. Discussed Three-phase bridge (dual) coupled 12-pulse (dynamic) commutation unit composed of high-voltage DC system faults and transient performance of operation. Not involved And multi-terminal HVDC transmission systems, but the parallel converters and parallel lines included in the systems at both ends are discussed. Assume that the inverter makes The thyristor valve is used as the bridge arm, and the gap-free metal oxide arrester is used for insulation coordination, and the power can be transmitted in both directions. This section does not Consider a diode valve. GB /Z20996 consists of three parts. Part 1 is steady state, Part 2 is fault and operation, Part 3 is dynamic. In the development and editing During the writing process, it has been avoided to repeat the three parts. Therefore, when the user prepares to prepare the specifications of the high-voltage DC system at both ends, Test the entire contents of the three parts. Pay attention to the differences between system performance specifications and equipment design specifications for each component in the system. This section does not specify equipment technology The technical conditions and test requirements, but focus on those technical requirements that affect the performance of the system. This section also does not include detailed seismic performance requirements. begging. In addition, there may be many differences between different HVDC systems. This section does not discuss this in detail. Therefore, this section should not Used directly as a technical specification for a specific engineering project. However, based on this, the specific transmission system can be programmed to meet the actual system. The technical specifications required. The content covered in this section does not distinguish between the responsibility of the user and the manufacturer. 1.2 Normative references The terms in the following documents become the terms of this section by reference in this section. All dated references, followed by all Modifications (not including errata content) or revisions do not apply to this section, however, parties to agreements based on this section are encouraged to study Is it possible to use the latest version of these files? For undated references, the latest edition applies to this section. GB 311.1-1997 Insulation coordination of high voltage power transmission and transformation equipment (neqIEC 60071-1.1993) GB/T 3859 (all) semiconductor inverter (GB/T 3859.1 ~ 3859.3-1993, eqv IEC 60146-1-1 ~ 60146-1-3.1991; GB/T 3859.4-2004, IEC 60646-2.1999, IDT) GB/T 13498 HVDC transmission terminology (GB/T 13498-2007, IEC 60633.1998, IDT) GB/T 20990.1 HV thyristor valves - Part 1. Electrical test (GB/T 20990.1-2007, IEC 60700- 1.1999, IDT) GB /Z20996.1-2007 Performance of high-voltage DC systems - Part 1. Steady state (IEC 60919-1.1988, IDT) GB /Z20996.3-2007 Performance of high voltage DC systems - Part 3. Dynamic (IEC 60919-3..1999, IDT)2 Overview of high voltage DC transient performance specifications2.1 Transient Performance Specifications The complete transient performance specification for HVDC systems during faults and operation shall include the protection requirements for faults. These concepts are described in the appropriate places for the following transient performance and corresponding terms. ---Chapter 3. Transient Process for Trouble-Free Operation ---Chapter 4. AC system failure ---Chapter 5. AC filter, reactive power equipment and AC bus fault ---Chapter 6. Converter unit failure GB /Z20996.2-2007/IEC /TR60919-2.1991 ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GBZ20996.2-2007_English be delivered?Answer: Upon your order, we will start to translate GBZ20996.2-2007_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GBZ20996.2-2007_English with my colleagues?Answer: Yes. The purchased PDF of GBZ20996.2-2007_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |