GB/T 9333-2009 English PDFUS$799.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 9333-2009: Electrical installation in ships -- Shipboard telecommunication cables and radio-frequency cables -- General instrumentation, control and communication cables Status: Obsolete GB/T 9333: Historical versions
Basic dataStandard ID: GB/T 9333-2009 (GB/T9333-2009)Description (Translated English): Electrical installation in ships -- Shipboard telecommunication cables and radio-frequency cables -- General instrumentation, control and communication cables Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: K13 Classification of International Standard: 29.060.20 Word Count Estimation: 20,226 Date of Issue: 2009-03-19 Date of Implementation: 2009-12-01 Older Standard (superseded by this standard): GB/T 9333.1-1988 Adopted Standard: IEC 60092-374-1977, MOD; IEC 60092-375-1977, MOD Regulation (derived from): Announcement of Newly Approved National Standards No. 3, 2009 (No. 143 overall) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the marine non-critical communication telephone cables and marine general instrumentation, control and communication equipment communication cable specifications, structure, properties and requirements. This standard applies to non-critical communications marine telephone cables and marine general instrumentation, control and communication equipment communication cable. This standard specifies the cables are mainly used in AC or DC 60V and below the work system, but also in case of failure of the AC or DC voltage 250V and below work. GB/T 9333-2009: Electrical installation in ships -- Shipboard telecommunication cables and radio-frequency cables -- General instrumentation, control and communication cables---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Electrical installation in ships.Shipboard telecommunication cables and radio-frequency cables.General instrumentation, control and communication cables ICS 29.060.20 K13 National Standards of People's Republic of China Replacing GB/T 9333.1-1988 Marine Electrical Equipment Shipboard telecommunication cables and radio frequency cables General instrumentation, control and communication cables (IEC 60092-374. 1977, Electricalinstalationinships- IEC 60092-375. 1977, MOD) Posted 2009-03-19 2009-12-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Table of ContentsIntroduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 2 4 Overview 2 5 conductor 2 6 Insulation 2 7 Stranding element 2 8 Stranding 3 9 shield 5 10 jacket 5 5 11 Cable Identification 12 finished cable 5 Appendix A (informative) Product Name and Code 9 Annex B (informative) This standard reg number and IEC 60092-374. 1977 and IEC 60092-375. 1977 Reg control number 11 Annex C (informative) This standard and IEC 60092-374. 1977 and IEC 60092-375. 1977 technical difference Its 12 different reasonsForewordThis revised standard adopts IEC 60092-374. 1977 "Electrical equipment of ships and marine communications cable RF cable non-critical communication Telephone cable "(in English) and IEC 60092-375. 1977" Electrical equipment of ships and marine communications cable RF cable general instrumentation, control System and the communication cable "(in English). The standard IEC 60092-374. 1977 and IEC 60092-375. 1977 made the following changes. --- Remove the IEC 60092-374. 1977 and IEC 60092-375. 1977 Foreword; --- Increase the national standard foreword; --- The "this publication" to "this standard"; --- Remove the IEC 60092-374. 1977 and IEC 60092-375. 1977 Foreword; --- Use the decimal symbol instead of decimal symbol ",". ","; --- Referenced standards, rather than the international standard of equivalent international standards; --- Some of the statements apply to international standards to apply to our standard formulation; --- Errata the IEC 60092-374. 1977 specified in the insulation resistance of not less than 45MΩ · km, instead 8MΩ · km. This standard replaces GB/T 9333.1-1988 "shipboard symmetrical communication cables - General." This standard and GB/T 9333.1-1988 have compared the following changes. --- Change the standard name, and IEC 60092-375. 1977 is consistent; --- Increasing the preface, in line with GB/T 1.1-2000 of the relevant provisions; --- Change the scope of application, covering IEC 60092-374. 1977 and IEC 60092-375. Scope 1977 (1988 edition Excerpts of chapter 1); Chapter 1; --- Change some reference standards, the use of a standard equivalent to international standards (1988 edition Chapter 2; Chapter 2 of this edition); --- Change GB/T 9333.1-1988 Chapter 3. definitions, terms and definitions instead. In line with GB/T 1.1-2000 regulation Set (1988 edition, Chapter 3; edition Chapter 3); --- Remove the GB/T 9333.1-1988 Chapter 4. Product name and code, this chapter moved informative Appendix A Excerpts Chapter 4, to "Overview" (1988 edition, Chapter 4; edition Chapter 4); --- Revised GB/T 9333.1-1988 Chapter 5. conductor, this chapter in accordance with IEC 60092-374. 1977 and IEC 60092-375. 1977 provisions were expressed (1988 edition Chapter 5; Chapter 5 of this edition); --- Revised GB/T 9333.1-1988 Chapter 6. insulation, this chapter in accordance with IEC 60092-374. 1977 and IEC 60092-375. 1977 provisions were expressed (1988 edition, Chapter 6; Chapter 6 of this edition); --- Revised GB/T 9333.1-1988 Chapter 7. cable core element to a cable, this chapter in accordance with IEC 60092-374. 1977 and IEC 60092-375. 1977 provisions were expressed (1988 edition, Chapter 7; Chapter 7 of this edition); --- Revised GB/T 9333.1-1988 Chapter 8. sheath, to a cable, this chapter in accordance with IEC 60092-374. 1977 and IEC 60092-375. 1977 provisions were expressed, see Chapter 10, covering sheath (1988 edition, Chapter 8; Chapter 8 of this edition); --- Revised GB/T 9333.1-1988 Chapter 9. Finished cable shield to this chapter in accordance with IEC 60092-374. 1977 and IEC 60092-375. 1977 provisions were expressed, finished cable see Chapter 12 (1988 edition, Chapter 9; Chapter 9 of this edition); --- Remove the GB/T 9333.1-1988 Chapter 10. Delivery length instead jacket, this chapter in accordance with IEC 60092-374. 1977 And IEC 60092-375. 1977 provisions were expressed (1988 edition Chapter 10; Chapter 10 of this edition); --- Remove the GB/T 9333.1-1988 in Chapter 11. Testing and inspection, to identify the cable, this chapter in accordance with IEC 60092- 374. 1977 and IEC 60092-375. 1977 provisions were expressed (1988 edition Chapter 11; Chapter 11 of this edition); --- Remove the GB/T 9333.1-1988 in Chapter 12. packaging, to the finished cable, this chapter in accordance with IEC 60092-374. 1977 And IEC 60092-375. 1977 provisions were expressed (1988 edition Chapter 12; Chapter 12 of this edition); --- Modify the insulation material to comply with IEC 60092-351.2004 specified mixture; --- Modify the jacket material to comply with IEC 60092-359.1999 provisions thereof. This standard Annex A, Annex B and Annex C is informative appendix. The standard proposed by China Electrical Equipment Industrial Association. This standard by the national wire and cable Standardization Technical Committee (SAC/TC213) centralized. This standard is drafted by. Shanghai Electric Cable Research Institute. Participated in the drafting of this standard. the Hai Saike force Optical Cable Co., China Shipbuilding Industry Corporation seventh ○ four Research Institute, China Shipbuilding Industry Corporation Seventh fifteen Research Institute, Shanghai Nanyang Cable Co., Ltd., Shanghai Nanyang Electric Wire Co., Ltd., Tianjin marries Technology Group Co., Ltd. Changzhou 8 Yi Cable Co., Ltd., Tianjin plastic power cable Group Limited. Drafters of this standard. Ye Qinghua, Guo Yi, Liu Zhen, Chen Li, in crystal, Zhang Hong, Tan Jinfeng, Chen Yuan, Li Yanhong, Syria Zhou Yuan, Meng and, Gao Huan, Ren Xiaoping. This standard replaces the standards previously issued as follows. --- GB/T 9333.1-1988. Marine Electrical Equipment Shipboard telecommunication cables and radio frequency cables General instrumentation, control and communication cables1 ScopeThis standard specifies the marine non-critical communication telephone cables and general marine instrumentation, control and communication equipment communication cable specifications, knot Configuration, and performance requirements. This standard applies to non-marine cables and telephone communication important marine general instrumentation, control and communication equipment communication cable. Cables in this standard is mainly used in AC or DC 60V and below the system of work, but also in case of failure or AC DC voltage 250V and below during normal operation.2 Normative referencesThe following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 2951.11-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 11. Common test methods - Thick Degree and diameter size measurement - mechanical tests (IEC 60811-1-1.2001, IDT) GB/T 3956-2008 conductor cable (IEC 60228.2004, IDT) GB/T 12269-1990 General specification for radio frequency cable (idt IEC 60096-1) GB/T 18380.12-2008 burning test and optical fiber cables under fire conditions - Part 12. single insulated wire and cable fire Test 1kW pre-mixed flame spread vertical flame test methods (IEC 60332-1-2.2004, IDT) GB/T 18380.22-2008 and optical fiber cables under fire conditions - Test - Part 22. single small insulated wire or cable Test for vertical flame spread diffusion flame test methods (IEC 60332-2-2.2004, IDT) GB/T 18380.33-2008 burning test and optical fiber cables under fire conditions - Part 33. vertically mounted bunched wires Cable vertical flame spread test class A (IEC 60332-3-22.2000, IDT) GB/T 19666-2005 retardant and fire-resistant wire and cable General GB/T 20637-2006 Electrical installations in ships shipboard power cables - General construction and test requirements (IEC 60092-350. 2001, IDT) IEC 60092-351.2004 Electrical installations in ships - Part 351. Marine and offshore platforms with power, control, instrumentation, and digital communications According to the cable insulation material IEC 60092-359.1999 Electrical installations in ships shipboard power and telecommunication cables with sheathing material IEC 60189-1. 1965 PVC insulation and PVC sheath frequency cables and wires - Part 1. General test and measurement Volume method IEC 60189-1.2007 PVC insulation and PVC sheath frequency cables and wires - Part 1. General test and measurement Volume method IEC 60189-2.2007 PVC insulation and PVC sheath frequency cables and wires - Part 2. Internal means double Core, three-core, four-core and five-core cable ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 9333-2009_English be delivered?Answer: Upon your order, we will start to translate GB/T 9333-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 9333-2009_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 9333-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 9333-2009?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 9333-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |