GB/T 778.5-2018 English PDFUS$264.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 778.5-2018: Meters for cold potable water and hot water -- Part 5: Installation requirements Status: Valid
Basic dataStandard ID: GB/T 778.5-2018 (GB/T778.5-2018)Description (Translated English): Meters for cold potable water and hot water -- Part 5: Installation requirements Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: N12 Classification of International Standard: 91.140.60 Word Count Estimation: 14,119 Date of Issue: 2018-06-07 Date of Implementation: 2019-01-01 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB/T 778.5-2018: Meters for cold potable water and hot water -- Part 5: Installation requirements---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Meters for cold potable water and hot water--Part 5. Installation requirements ICS 91.140.60 N12 National Standards of People's Republic of China Replace GB/T 778.2-2007 Drinking cold water meter and hot water meter Part 5. Installation requirements Part 5. Instalationrequirements (ISO 4064-5.2014, Watermetersforcoldpotablewaterandhotwater- Part 5. Instalationrequirements, IDT) Published on.2018-06-07 2019-01-01 implementation State market supervision and administration China National Standardization Administration issued ForewordGB/T 778 "Drinking cold water meter and hot water meter" is divided into the following five parts. --- Part 1. Measurement requirements and technical requirements; --- Part 2. Test methods; --- Part 3. Test report format; --- Part 4. Non-metering requirements not included in GB/T 778.1; --- Part 5. Installation requirements. This part is the fifth part of GB/T 778. This part is drafted in accordance with the rules given in GB/T 1.1-2009. This part replaces GB/T 778.2-2007 "Measurement of water flow in closed full pipes. Drinking cold water meter and hot water meter. Part 2 Minute. Installation Requirements. The main technical content changes compared with GB/T 778.2-2007 are as follows. ---Modified standard name; --- Revised scope (see Chapter 1, Chapter 1 of GB/T 778.2-2007); --- Added the term "adapter" to "converter" (see 3.3, 3.4); --- Remove other conditions that should be considered when installing the water meter (see 6.2.21 of GB/T 778.2-2007); --- Increased the requirement that the plug-in water meter interface cannot use the adapter (see 7.2.8); --- Removed the contents of the "impact or vibration transmitted or caused by the water supply facility" in the protection of the water meter (see GB/T 778.2-2007) 8.3.3); --- Removed the "stress and imbalance caused by water supply facilities" in the protection of water meters (see 8.3.5 of GB/T 778.2-2007); --- Increased installation requirements for cartridge-mounted water meters (see 8.3.4); --- Increased installation requirements for interchangeable metering water meters (see 8.3.5); --- Removed the requirement of "fixed piping system" in personal safety (see 8.4.2 of GB/T 778.2-2007); --- Revised the requirements for the quality of water meters in the requirements for the passage of large-scale water meters (see 8.5.1, GB/T 778.2-2007) 8.5.1). This section uses the translation method equivalent to ISO 4064-5.2014 "Drinking cold water meters and hot water meters Part 5. Installation requirements". The documents of our country that have a consistent correspondence with the international documents referenced in this part are as follows. ---GB/T 18660-2002 Measurement of the flow rate of conductive liquids in closed pipes - Methods of use of electromagnetic flowmeters (ISO 6817. 1992, IDT) This part was proposed by the China Machinery Industry Federation. This part is under the jurisdiction of the National Industrial Process Measurement Control and Automation Standardization Technical Committee (SAC/TC124). This section drafted by. Shanghai Industrial Automation Instrumentation Research Institute Co., Ltd., Ningbo Water Meter Co., Ltd., Sanchuan Wisdom Technology Company, Ningbo Donghai Instrument Waterway Co., Ltd., Suzhou Waterworks Co., Ltd., Zhejiang Institute of Metrology, Henan Province Department of Metrology Institute of Science and Technology, Ningbo Metrology and Testing Institute, Nanjing Water Group Co., Ltd. Water Meter Factory, Chongqing Smart Water Meter Co., Ltd., Wuxi Water Table limited liability company, Shanghai Water Meter Factory, Shanghai Instrumentation Automatic Control System Inspection and Testing Institute, Hangzhou Water Meter Co., Ltd., Shenzhen Jiexian Digital Technology Co., Ltd., Huizhong Instrument Co., Ltd., Fuzhou Kerong Instrument Co., Ltd., Yangzhou Hengxin Instrument Co., Ltd., Beijing Tap Water Group Jingzhao Water Meter Co., Ltd., Jinan Ruiquan Electronics Co., Ltd., Hangzhou Jingda Electronics Co., Ltd., Jiangyin Lixin Intelligent Equipment Company, Hunan Changde Water Meter Manufacturing Co., Ltd., Ningbo Jingcheng Technology Co., Ltd., Hunan Weiming Energy Technology Co., Ltd., Qing Island Jicheng Electronics Co., Ltd., Tianjin Sain Energy Technology Co., Ltd. The main drafters of this section. Li Minghua, Zhao Shaoman, Song Caihua, Lin Zhiliang, Yao Fujiang, Zhao Jianliang, Cui Yaohua, Ma Jun, Lu Congwen, Wei Qinghua, Zhang Qing, Chen Yu, Xie Jianliang, Chen Jian, Zhang Jichuan, Chen Hanzhang, Zhang Jian, Zhang Wenjiang, Dong Liangcheng, Du Jiquan, Han Lu, Zhu Zhengjian, Tang Tianshun, Liao Jie, Zhang Dexia, Zuo Wei, Wang Jianing, Song Yanyong, Wang Xinxin, Wang Qinli. The previous versions of the standards replaced by this section are. ---GB 778-1984 ---GB/T 778.2-1996, GB/T 778.2-2007. Drinking cold water meter and hot water meter Part 5. Installation requirements1 ScopeThis part of GB/T 778 specifies the selection, installation and special requirements of water meters for single water meters, double water meters, coaxial water meters and connecting pipes. Seek guidelines for the first use of new or improved water meters to ensure accurate and stable measurements and reliable readings. This section applies to water meters that measure the volume of drinking cold water and hot water in a closed full pipe and are equipped with a cumulative flow indicating device. This section applies to both water-based and mechanical-based water meters, as well as based on electrical or electronic principles and based on mechanical principles, A water meter used to measure the volume of cold water and hot water. This section also applies to electronic aids. Usually the electronic aid is an option. However, national or international regulations may determine certain auxiliary devices as necessary for the use of the water meter. The recommendations in this section apply to water meters that are defined as integrated meters and that continuously measure the volume of water flowing through any technique. Note. National regulations are higher than the provisions of this section.2 Normative referencesThe following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 778.1-2018 Drinking cold water meters and hot water meters - Part 1. Quantitative requirements and technical requirements (ISO 4064-1. 2014, IDT) ISO 6817 Measurement of the flow rate of conductive liquids in closed pipes. Method of use of electromagnetic flowmeters (Measurementof Conductiveliquidflowinclosedconduits-Methodusingelectromagneticflowmeters)3 Terms and definitionsThe following terms and definitions as defined in GB/T 778.1-2018 apply to this document. 3.1 Parallel operation in parallel < Water Meter> Two or more water meters are connected to a common water source and a public water supply pipe. 3.2 Multi-table running multiplemeteroperation The water inlets of several water meters are connected to a common water source, or the outlets are connected to a common water supply pipe (two The situation does not exist at the same time). 3.3 Adapter adaptor < Water meter> is used to connect the plug-in water meter with different geometrical and unmodified shapes to the connection interface of another geometric size. A mechanical device mounted on the connection interface. 3.4 Converter converter < Water Meter> A connection interface of a complete unit consisting of several components before being loaded into the water supply system. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 778.5-2018_English be delivered?Answer: Upon your order, we will start to translate GB/T 778.5-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 778.5-2018_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 778.5-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |