GB/T 6150.9-2009 English PDFUS$139.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 6150.9-2009: Methods for chemical analysis of tungsten concentrates -- Determination of copper content -- Flame atomic absorption spectrometry Status: Valid GB/T 6150.9: Historical versions
Basic dataStandard ID: GB/T 6150.9-2009 (GB/T6150.9-2009)Description (Translated English): Methods for chemical analysis of tungsten concentrates -- Determination of copper content -- Flame atomic absorption spectrometry Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: H63 Classification of International Standard: 77.120.99 Word Count Estimation: 6,648 Date of Issue: 2009-10-30 Date of Implementation: 2010-06-01 Older Standard (superseded by this standard): GB/T 6150.11-1985 Regulation (derived from): National Standard Approval Announcement 2009 No.12 (Total No.152) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the method for determination of copper content of tungsten concentrates. This section applies to the determination of copper content of tungsten concentrates. Measuring range: 0. 005% to 1. 00%. GB/T 6150.9-2009: Methods for chemical analysis of tungsten concentrates -- Determination of copper content -- Flame atomic absorption spectrometry---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Methods for chemical analysis of tungsten concentrates.Determination of copper content.Flame atomic absorption spectrometry ICS 77.120.99 H63 National Standards of People's Republic of China Replacing GB/T 6150.11-1985 Methods for chemical analysis of tungsten concentrates - Determination of copper content Flame Atomic Absorption Spectrometry Posted 2009-10-30 2010-06-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordGB/T 6150 "Methods for chemical analysis of tungsten concentrates" is divided into 17 parts. Determination of GB/T 6150.1 Methods for chemical analysis of tungsten concentrates of tungsten trioxide amount of ammonium tungstate burning gravimetric method GB/T 6150.2 Methods for chemical analysis of tungsten concentrates - Determination of tin content of potassium iodate volumetric method and hydride generation atomic absorption spectrometry GB/T 6150.3 Methods for chemical analysis of tungsten concentrates - Determination of phosphorus content of phosphorus molybdenum yellow spectrophotometry Determination of GB/T 6150.4 Methods for chemical analysis of tungsten concentrates sulfur content of high frequency infrared absorption method Determination of EDTA volumetric method and atomic GB/T 6150.5 Methods for chemical analysis of tungsten concentrates calcium absorption spectrometry GB/T 6150.6 Methods for chemical analysis of tungsten concentrates - Determination of hygroscopic water gravimetric method GB/T 6150.7 Methods for chemical analysis of tungsten concentrates - Determination of the amount of tantalum and niobium plasma emission spectroscopy and spectrophotometry GB/T 6150.8 Methods for chemical analysis of tungsten concentrates - Determination of molybdenum content - Thiocyanate spectrophotometric GB/T 6150.9 Methods for chemical analysis of tungsten concentrates - Determination of copper content - Flame atomic absorption spectrometry GB/T 6150.10 Methods for chemical analysis of tungsten concentrates - Determination of lead content by flame atomic absorption spectrometry GB/T 6150.11 Methods for chemical analysis of tungsten concentrates of zinc content - Flame Atomic Absorption Spectrometry GB/T 6150.12 Methods for chemical analysis of tungsten concentrates - Determination of silicon dioxide content and weight of molybdenum blue spectrophotometric method Hydride atomic GB/T 6150.13 Methods for chemical analysis of tungsten concentrates the amount of arsenic absorption spectroscopy and spectroscopic DDTC-Ag Spectrophotometry GB/T 6150.14 Methods for chemical analysis of tungsten concentrates - Determination of manganese content of ammonium ferrous sulfate volumetric method and flame atomic absorption spectrometry GB/T 6150.15 Methods for chemical analysis of tungsten concentrates bismuth content - Flame Atomic Absorption Spectrometry GB/T 6150.16 Methods for chemical analysis of tungsten concentrates - Determination of iron content sulfonic acid spectrophotometry Hydride atomic GB/T 6150.17 Methods for chemical analysis of tungsten concentrates antimony content absorption spectrometry This section Part 9 GB/T 6150's. This Part replaces GB/T 6150.11-1985 "chemical analysis of tungsten concentrates - The atomic absorption spectrophotometric determination of copper content." Section compared with the GB/T 6150.11-1985 The main changes are as follows. --- Assay medium with hydrochloric acid to nitric acid; --- Expanded measurement range from 0.005 percent to 0.500 percent to 0.005% to 1.00%; --- Standard solution by adding hydrochloric acid, perchloric acid was added to a solution of nitric acid; --- Increased repeatability terms. This part is proposed by the China Nonferrous Metals Industry Association. The non-ferrous metal part by the National Standardization Technical Committee. This section is Ganzhou Nonferrous Metallurgy Research Institute, China Nonferrous Metals Industry Institute of Standards Metrology and Quality is responsible for drafting. This section was drafted by Ganzhou Nonferrous Metallurgy Research Institute. This section is under ridge Jiangxi Tungsten Industry Co., Ltd., Ganzhou Huaxing Tungsten Products Co., Ltd. participated in the drafting. The main drafters of this section. Tao, Lai Jian, Zhong Daoguo, Shijiang Hai. This part certifier. Xu Jingguang, Wang Changji, Ge Weihong. This part of the standard replaces the previous editions are. --- GB/T 6150.11-1985. Methods for chemical analysis of tungsten concentrates - Determination of copper content Flame Atomic Absorption Spectrometry1 ScopeGB/T 6150 This section provides the determination of copper content of tungsten concentrates. This section applies to the determination of copper content of tungsten concentrates. Measurement range. 0.005% to 1.00%.2 Method summarySample in a boiling water bath to decompose hydrochloric acid, nitric acid, perchloric acid is heated to dissolve the thick white smoke to take, remove cooling, nitric acid, the nitrate Acid medium, atomic absorption spectrometer at a wavelength of 324.8nm, air - acetylene flame measured the absorbance of copper, calculated using the working curve method Copper quality scores. Tungsten concentrate of impurities did not interfere.3 ReagentsUnless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or relative purity of water. 3.1 hydrochloride (ρ1.19g/mL). Nitrate 3.2 (ρ1.42g/mL). 3.3 perchloric acid (ρ1.67g/mL). 3.4 nitric acid (1 + 1). 3.5 copper standard stock solution. Weigh 0.2000g pure copper [Cu≥99.99%] in 300mL beaker, add 100mL nitric acid (3.4), dissolved by heating, cooling and 1000mL flask in constant volume, mix, and this solution 1mL containing 200μg copper.4 InstrumentAtomic absorption spectrometer, with copper hollow cathode lamp. Under optimum working conditions for those who can reach the following indicators can be used. --- Characteristic concentration. In line with the measuring solution matrix solution features copper concentration should be less than 0.059μg/mL. --- Precision. standard solution with the highest concentration of 10 times the absorbance measurements, the standard deviation should not exceed 1.5% of the average absorbance; With the lowest concentration of standard solution (not "zero" concentration of the standard) measuring the absorbance of 10 times, the standard deviation should not exceed the maximum The average concentration of 0.5% absorbance. --- Linear curve. The curve is divided into five sections according to concentration, absorbance difference between the absorbance difference between the highest and the lowest segment of the segment Ratio should not be less than 0.7.5 Sample5.1 Sample size of less than 0.074mm. 5.2 sample was pretreated at 105 ℃ ~ 110 ℃ drying 2h, placed in a desiccator to cool to room temperature. Step 6 Analysis 6.1 Sample Table 1 sample was weighed (accurate to 0.0001g). ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 6150.9-2009_English be delivered?Answer: Upon your order, we will start to translate GB/T 6150.9-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 6150.9-2009_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 6150.9-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 6150.9-2009?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 6150.9-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |