Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 4325.6-2013 PDF English

US$130.00 · In stock · Download in 9 seconds
GB/T 4325.6-2013: Methods for chemical analysis of molybdenum - Part 6: Determination of arsenic content - Atomic fluorescence spectrometry
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid

GB/T 4325.6: Historical versions

Standard IDUSDBUY PDFDeliveryStandard Title (Description)Status
GB/T 4325.6-2013130 Add to Cart Auto, 9 seconds. Methods for chemical analysis of molybdenum - Part 6: Determination of arsenic content - Atomic fluorescence spectrometry Valid
GB/T 4325.6-1984199 Add to Cart 2 days Methods for chemical analysis of molybdenum--The ortho-phenanthroline photometric method for the determination of iron content Obsolete

Similar standards

GB/T 4325.7   GB/T 4325.5   GB/T 4325.8   GB/T 4325.1   

GB/T 4325.6-2013: Methods for chemical analysis of molybdenum - Part 6: Determination of arsenic content - Atomic fluorescence spectrometry


---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT4325.6-2013
GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 77.120.99 H 63 Replacing GB/T 4325.5-1984 Methods for chemical analysis of molybdenum - Part 6: Determination of arsenic content - Atomic fluorescence spectrometry ISSUED ON: MAY 09, 2013 IMPLEMENTED ON: FEBRUARY 01, 2014 Issued by: General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of the People's Republic of China.

Table of Contents

Foreword ... 3 1 Scope ... 6 2 Method summary ... 6 3 Reagents ... 6 4 Instruments ... 7 5 Specimen ... 8 6 Analysis steps ... 8 7 Calculation of analysis result ... 9 8 Precision ... 9 9 Test report ... 10

Foreword

GB/T 4325 “Methods for chemical analysis of molybdenum” consists of the following 26 parts: - Part 1: Determination of lead content - Graphite furnace atomic absorption spectrometry; - Part 2: Determination of cadmium content - Flame atomic absorption spectrometry; - Part 3: Determination of bismuth content - Atomic fluorescence spectrometry; - Part 4: Determination of tin content - Atomic fluorescence spectrometry; - Part 5: Determination of antimony content - Atomic fluorescence spectrometry; - Part 6: Determination of arsenic content - Atomic fluorescence spectrometry; - Part 7: Determination of iron content - 1,10-phenanthroline spectrophotometry and inductively coupled plasma atomic emission spectrometry; - Part 8: Determination of cobalt content - 5-Cl-PADAB spectrophotometry and flame atomic absorption spectrometry; - Part 9: Determination of nickel content - Dimethylglyoxime spectrophotometry and flame atomic absorption spectrometry; - Part 10: Determination of copper content - Flame atomic absorption spectrometry; - Part 11: Determination of aluminum content – Chrome azurol S spectrophotometry and inductively coupled plasma atomic emission spectrometry; - Part 12: Determination of silicon content - Inductively coupled plasma atomic emission spectrometry; - Part 13: Determination of calcium content - Flame atomic absorption spectrometry; - Part 14: Determination of magnesium content - Flame atomic absorption spectrometry; Methods for chemical analysis of molybdenum - Part 6: Determination of arsenic content - Atomic fluorescence spectrometry

1 Scope

This Part of GB/T 4325 specifies the method to determine arsenic content in molybdenum. This Part is applicable to the determination of arsenic content in molybdenum powder, molybdenum bar, molybdenum trioxide, ammonium molybdate. The determination range is 0.0002%~0.0050%.

2 Method summary

The test material is decomposed with hydrogen peroxide. In thiourea-ascorbic acid-hydrochloric acid medium, use hydride generation-atomic fluorescence spectrometry to determine arsenic content. Within a certain range, the fluorescence intensity is proportional to the content of the measured element. Adding molybdenum matrix can eliminate interference.

3 Reagents

Unless otherwise specified, the reagents used in this Part are guaranteed reagents; water used is grade two or above. 3.1 Sodium borohydride. 3.2 Sodium hydroxide. 3.3 Molybdenum matrix (wAs≤0.00002%). 3.4 Arsenic trioxide (wAs2O3≥99.99%). 3.5 Nitric acid (ρ=1.42g/mL). 3.6 Hydrochloric acid (ρ=1.19g/mL). 3.7 Sulfuric acid (ρ=1.84g/mL). 3.8 Hydrogen peroxide. 3.9 Sulfuric acid (1+1). 3.10 Sulfuric acid (1+4). 3.11 Sodium hydroxide solution (200g/L). 3.12 Thiourea-ascorbic acid solution: Weigh 10g of thiourea and 10g of ascorbic acid respectively to dissolve in 200mL of water. Mix well. Prepare when it is required. 3.13 Arsenic standard stock solution: Weigh 0.1320g of arsenic trioxide (3.4). Add 20mL of water, 0.2g of sodium hydroxide (3.2). Heat to dissolve. Use sulfuric acid (3.10) to neutralize to slightly acidic. Transfer into a 1000mL volumetric flask. Use water to dilute to the scale. 1mL of this solution contains 100μg of arsenic. 3.14 Arsenic standard solution: Pipette 1.00mL of arsenic standard stock solution (3.13) into a 100mL volumetric flask. Add 10mL of hydrochloric acid (3.6). Use water to dilute to the scale. Mix well. 1mL of this solution contains 1μg of arsenic. 3.15 Sodium borohydride solution: Weigh 1.5g of sodium borohydride (3.1). Add into 100mL of water that 1g of sodium hydroxide (3.2) is pre-dissolved. Shake well after dissolving completely. Prepare when it is required. 3.16 Hydrochloric acid (1+9). 3.17 Argon: the volume fraction is not less than 99.99%.

4 Instruments

Atomic fluorescence spectrometer, with arsenic special hollow cathode lamp. Under the best working conditions of the instrument, anyone who can reach the following indicators can be used. - Detection limit: not more than 1×10-9g/mL; - Precision: use 0.02μg/mL arsenic standard solution to measure fluorescence intensity 10 times; its standard deviation does not exceed 5.0% of the fluorescence intensity; - Linear of working curve: divide the working curve into five equal segments according to the concentration; the ratio of the difference in fluorescence intensity between the highest segment and the lowest segment shall be ......

Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Image 1     Image 2     Image 3     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of English version of GB/T 4325.6-2013 be delivered?Answer: The full copy PDF of English version of GB/T 4325.6-2013 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of GB/T 4325.6-2013_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 4325.6-2013_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 4325.6-2013 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

Question 5: Should I purchase the latest version GB/T 4325.6-2013?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 4325.6-2013 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.

How to buy and download a true PDF of English version of GB/T 4325.6-2013?

A step-by-step guide to download PDF of GB/T 4325.6-2013_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "GB/T 4325.6-2013".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9