GB/T 4701.10-2008 English PDFUS$229.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 4701.10-2008: Ferrotitanium -- Determination of sulfur content -- Infrared absorption method and combustion-neutralization titration method Status: Valid GB/T 4701.10: Historical versions
Basic dataStandard ID: GB/T 4701.10-2008 (GB/T4701.10-2008)Description (Translated English): Ferrotitanium -- Determination of sulfur content -- Infrared absorption method and combustion-neutralization titration method Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: H11 Classification of International Standard: 77.100 Word Count Estimation: 10,195 Date of Issue: 2008-05-13 Date of Implementation: 2008-11-01 Older Standard (superseded by this standard): GB/T 4701.10-1988; GB/T 4701.11-1988 Quoted Standard: GB/T 4010 Regulation (derived from): National Standard Approval Announcement 2008 No.8 (Total No.121) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the infrared absorption method and titration method and the combustion of sulfur content in ilmenite. This section applies to the determination of the sulfur content of ilmenite. Which measured the infrared method range: from 0. 005% to 0. 045%, combustion and titration range: 0. 005% to 0. 070 %. GB/T 4701.10-2008: Ferrotitanium -- Determination of sulfur content -- Infrared absorption method and combustion-neutralization titration method---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Ferrotitanium. Determination of sulfur content. Infrared absorption method and combustion-neutralization titration method ICS 77.100 H11 National Standards of People's Republic of China Replacing GB/T 4701.10 ~ 4701.11-1988 Determination of sulfur content of ilmenite The infrared absorption method and combustion titration method Posted 2008-05-13 2008-11-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThis part is GB/T 4701.10-1988 "Methods for chemical analysis of ferrotitanium The infrared absorption method for the determination of sulfur content" GB/T 4701.11-1988 "Methods for chemical analysis of ferrotitanium determination of sulfur content and combustion titration" integration amendment. This Part replaces GB/T 4701.10-1988, GB/T 4701.11-1988. This portion of the GB/T 4701.10-1988 and GB/T 4701.11-1988 comparison, the main changes are as follows. --- Infrared absorption method Sample volume is adjusted by the 0.500g 0.25g; --- Infrared absorption method flux increased from 0.50g tin particles, 1.50g to 0.25g tungsten particles tin particles, 1.0g tungsten particles, and add Into 0.50g of pure iron; --- Combustion and titration measurement range from the original ≤0.070% to 0.005% to 0.070%. This part is proposed by the China Iron and Steel Association. This section is under the jurisdiction of Metallurgical Industry Information Standards Institute. This section is drafted. Changshu CIQ. The main drafters of this section. Xu Yuyu, a new kingdom, Wu Cheng, Zhu Yuyan. This part replaces the standards previously issued as follows. --- GB/T 4701.10-1988; --- GB/T 4701.11-1988. Determination of sulfur content of ilmenite The infrared absorption method and combustion titration method Warning. Use of this section shall be a person experiences regular laboratory work. This section does not indicate that all possible security issues. Users have the responsibility to take appropriate safety and health practices and to ensure compliance with the conditions relevant national regulations.1 ScopeThis section provides an infrared absorption method and combustion titration and determination of sulfur content in ferrotitanium. This section applies to the determination of sulfur content of ilmenite. Wherein the measurement range infrared method (mass fraction). 0.005% and 0.045%; combustion And titration range (mass fraction). 0.005% to 0.070%.2 Normative referencesThe following documents contain provisions which, through reference in this text, constitute provisions of this part. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this section, however, encourage the parties to this part of the research agreement Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this section. GB/T 4010 alloy chemical analysis and preparation of samples for. 3 Method One. The infrared absorption method 3.1 Principle The sample is heated in an induction furnace in an oxygen stream of combustion, the oxygen produced by the sulfur dioxide contained in the measuring chamber to the infrared analyzer dioxide A sulfur absorbing specific wavelengths of infrared energy, which is proportional to the absorbed energy and the concentration of sulfur dioxide, according to the change in energy receiving detector may be measured Sulfur content. 3.2 Reagents and materials Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or equivalent purity. 3.2.1 magnesium perchlorate, anhydrous, granular. 3.2.2 asbestos caustic soda, granular. 3.2.3 glass wool. 3.2.4 tungsten particles, sulfur content is less than 0.0002%, particle size 0.8mm ~ 1.4mm. 3.2.5 tin particles, sulfur content is less than 0.0003%, particle size 0.4mm ~ 0.8mm. 3.2.6 pure iron purity of more than 99.80%, a sulfur content of less than 0.0005%, particle size 0.8mm ~ 1.68mm. 3.2.7 oxygen purity of more than 99.95%, if other levels of oxygen to obtain a low and consistent blank value, may also be used. 3.2.8 power source gas, nitrogen or compressed air, which contaminants (oil and water) of less than 0.5%. 3.2.9 ceramic crucible diameter × height, 23mm × 23mm or 25mm × 25mm, and above 1200 ℃ high temperature furnace 4h or by burning oxygen burning to blank the lowest value. 3.2.10 crucible tongs. 3.3 Instrument 3.3.1 Sulphur infrared absorption analyzer (sensitivity of 1.0 × 10-6) which means shown in Figure 1. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 4701.10-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 4701.10-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 4701.10-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 4701.10-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 4701.10-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 4701.10-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |