GB/T 41073-2021 English PDFUS$414.00 ยท In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 41073-2021: Surface chemical analysis - Electron spectroscopies - Minimum reporting requirements for peak fitting in X-ray photoelectron spectroscopy Status: Valid
Basic dataStandard ID: GB/T 41073-2021 (GB/T41073-2021)Description (Translated English): Surface chemical analysis - Electron spectroscopies - Minimum reporting requirements for peak fitting in X-ray photoelectron spectroscopy Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: G04 Word Count Estimation: 22,265 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB/T 41073-2021: Surface chemical analysis - Electron spectroscopies - Minimum reporting requirements for peak fitting in X-ray photoelectron spectroscopy---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Surface chemical analysis -- Electron spectrocopies -- Minimum reporting requirements for peak fitting in X-ray photoelectron spectroscopy ICS 71:040:40 CCSG04 National Standards of People's Republic of China Surface Chemical Analysis Electron Spectroscopy X-ray Basic Requirements for Peak Fitting Reports for Photoelectron Spectra (ISO 19830:2015, IDT) Published on 2021-12-31 2022-07-01 Implementation State Administration for Market Regulation Released by the National Standardization Administration directory Preface III Introduction IV 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Symbols and Abbreviations 2 5 Relevant data collection parameter report 2 5:1 Overview 2 5:2 Spectrometer 3 5:3 Instrument resolution 3 5:4 Detector 3 5:5 X-ray source 3 5:6 Element Identification 4 5:7 Spectral energy range 4 5:8 Spectral energy step 4 5:9 Charge Compensation 4 6 Single Spectrum Peak Fitting Parameter Report 4 6:1 Overview 4 6:2 Background range 4 6:3 Background integration range 4 6:4 Background Type 4 6:5 Fitting background applications 5 6:6 Setting Peak Parameters 5 6:7 Peak area and peak height 5 6:8 Peak area ratio and peak height ratio 5 6:9 Half peak width5 6:10 Peak shape 5 6:11 Peak asymmetry parameter 6 6:12 Peak Fitting Processing 6 6:13 Residual Spectrum 6 7 Multiplex Fitting 6 7:1 Overview 6 7:2 Peak Fitting Methods for Multiplet Datasets 6 7:3 Constraint propagation 6 7:4 Background propagation 7 8 satellite peak deduction 7 9 Double Peaks Deduction 8 10 Spectral deconvolution8 11 Fit quality and uncertainty 8 11:1 Overview 8 11:2 Fit quality 8 11:3 Uncertainty of binding energy 8 11:4 Uncertainty of Peak Area 8 Appendix A (Informative) Reported Peak Fit Example 9 Appendix B (Informative) Multilayer Dataset Peak Fitting Report 12 Appendix C (Informative) Reported Peak Fitting Parameter Template 14 Appendix D (Informative) Statistical Methods 15 Reference 17 forewordThis document is in accordance with the provisions of GB/T 1:1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules of Standardization Documents" drafted: This document is identical to ISO 19830:2015 "Surface Chemical Analysis Electron Spectroscopy X-ray Photoelectron Spectrum Peak Fitting Report" this requirement": This document adds a chapter "Normative References": Please note that some content of this document may be patented: The issuing agency of this document assumes no responsibility for identifying patents: This document is proposed and managed by the National Microbeam Analysis Standardization Technical Committee (SAC/TC38): This document is drafted by: Institute of Chemistry, Chinese Academy of Sciences, China Petroleum & Chemical Corporation Petrochemical Research Institute: The main drafters of this document: Zhao Zhijuan, Qiu Limei, Liu Fen, Zhang Xiaoyu, Wang Yanhua:IntroductionThe X-ray photoelectron spectroscopy (XPS) spectra obtained on the surface of many materials are complex, and often contain overlapping or indistinguishable peak: Insufficiency of resolution may be due to instrument parameters, X-ray linewidth, the natural linewidth of the transition, or a combination of all factors: therefore, It is often necessary to mathematically fit some or all of the peaks in the XPS spectrum to determine the position of each component peak contained in the envelope of each peak: placement and strength: Generating an overall peak envelope and quantifying the individual chemical states present is often the first step in the identification of chemical states: Therefore, divide The analyst must confirm the position (for chemical state determination) and peak area (for accurate quantification) of each peak reported after the peak fit: The mathematical method applies model peak and background shapes, and the defined parameters are variable in order to obtain the best fit to the experimental data: Most common The peak shape of the model peak is a combination of Gaussian and Lorentzian functions: The parameters that should be reported after peak fitting are mostly those that define those curves: Other factors are selected by the analyst to ensure peak fit processing The results conform to the chemically meaningful description of the peak envelope or minimize the time required for the fitting process: Actions performed by the analyst include: --- select parameter values to be fixed in the fit; --- Determine the range of variable parameter values in the fit; --- Mathematically associate one parameter value with another parameter value: Peak fitting is a purely mathematical process to obtain quantitative and qualitative results that may be related to the chemical properties of the analyzed surface: The fitting result will depend on Depending on the analyst's choice of parameters and constraints, the choice can affect the analyst's interpretive conclusions from the peak fitting results: Therefore, report These parameters and constraints are important: This will allow other analysts to do the following: --- Assess the reliability and validity of conclusions drawn from peak fitting; --- Repeating the peak fitting process on the same data set can get the same results; --- Repeating the peak fitting process on data obtained from similar samples allows for efficient comparison of data sets: Most software packages for XPS data processing include peak fitting routines: These programs allow the operator to select the appropriate parameters to and fitting with the required constraints: It is likely that the software will provide an output that reports this information and facilitates copying for other The output of the spectral fitting process: Such output will facilitate reporting of appropriate parameters: This document does not provide instructions for XPS peak fitting or for correlating peak fitting processing results with the chemical properties of the surfaces being analyzed: fact Above, in the examples in this document, the fit shown does not represent the only method by which a fit can be performed, or even the best method for peak fitting: This These examples are for illustrative purposes only: Surface Chemical Analysis Electron Spectroscopy X-ray Basic Requirements for Peak Fitting Reports for Photoelectron Spectra1 ScopeThis document specifies how to report peak fits of X-ray photoelectron spectroscopy and their results: This document applies to the fitting of a single spectrum or a set of related spectra, such as a set of related spectra acquired in a depth profiling test: This document provides a list of parameters that should be reported in order to achieve reproducible peak fitting or to fit and compare multiple spectra: This document does not provide operating instructions for peak fitting, nor the fitting steps that should be taken:2 Normative referencesThere are no normative references in this document:3 Terms and DefinitionsThe following terms and definitions apply to this document: 3:1 Inelastic background, inelastic Due to single or multiple inelastic scattering processes, particles originally at one energy are now emitted at lower energies and appear more intense in the spectrum degree distribution: [Source: ISO 18115-1, 4:50] 3:2 Shirley background, Shirley The background calculated when fitting the measured spectrum at kinetic energies above and below this peak or meaningful peak, such that the background at a given kinetic energy is the same as The total peak area at higher kinetic energies above background is a fixed proportion of the composition: [Source: ISO 18115-1:2010, 4:54] 3:3 Tougaard background,Tougaard Intensities obtained using a differential inelastic scattering cross-section model with respect to energy loss and a three-dimensional distribution model of emitting atoms in the surface region distributed: [Source: ISO 18115-1:2010, 4:57] 3:4 passenergy The average kinetic energy of the measured particle in the energy dispersive region located in the energy analyzer: [Source: ISO 18115-1:2010, 4:325] 3:5 peak fitting Steps to adjust the spectrum produced by peak synthesis to match the measured spectrum: ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 41073-2021_English be delivered?Answer: Upon your order, we will start to translate GB/T 41073-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 41073-2021_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 41073-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |