GB/T 40915-2021 English PDFUS$189.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 40915-2021: Determination of SiO2, Al2O3, Fe2O3, K2O, Na2O, CaO, MgO content of soda-lime-silica glass by X-ray fluorescence spectrometric method Status: Valid
Basic dataStandard ID: GB/T 40915-2021 (GB/T40915-2021)Description (Translated English): Determination of SiO2, Al2O3, Fe2O3, K2O, Na2O, CaO, MgO content of soda-lime-silica glass by X-ray fluorescence spectrometric method Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: Y22 Word Count Estimation: 10,163 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB/T 40915-2021: Determination of SiO2, Al2O3, Fe2O3, K2O, Na2O, CaO, MgO content of soda-lime-silica glass by X-ray fluorescence spectrometric method---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Determination of SiO2, Al2O3, Fe2O3, K2O, Na2O, CaO, MgO content of soda-lime-silica glass by X-ray fluorescence spectrometric method ICS 81.040.01 CCSY22 National Standards of People's Republic of China Determination of SiO2 in soda lime silica glass by X-ray fluorescence spectrometry Released on 2021-11-26 2022-06-01 implementation State Administration for Market Regulation Issued by the National Standardization Management Committee ForewordThis document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules of Standardization Documents" Drafting. Please note that some of the contents of this document may involve patents. The issuing agency of this document is not responsible for identifying patents. This document was proposed by the China National Light Industry Council. This document is under the jurisdiction of the National Daily Glass Standardization Technical Committee (SAC/TC377). This document was drafted by. Guangdong Huaxing Glass Co., Ltd., Anhui Xinmin Glass Co., Ltd., Shandong Jingyao Glass Group Co., Ltd., Donghua University, Shandong Huapeng Glass Co., Ltd., National Quality Supervision and Inspection Center for Glasses and Enamel Products. The main drafters of this document. Chen Songlin, Liu Fenglian, Ye Jiayi, Wang Helan, Zhang Dapeng, Xu Xiaojian, Wu Jiaxu, Tang Yong, Zhao Yingxian, Zhang Guoxiu, Sun Huanbao, Wang Lianjun, Chen Renhua. Determination of SiO2 in soda lime silica glass by X-ray fluorescence spectrometry Al2O3, Fe2O3, K2O, Na2O, CaO, MgO content1 ScopeThis document describes the X-ray fluorescence spectra of SiO2, Al2O3, Fe2O3, K2O, Na2O, CaO, MgO content in soda lime silica glass test methods. This document is applicable to the determination of SiO2, Al2O3, Fe2O3, K2O, Na2O, CaO, MgO content in soda lime silica glass.2 Normative referencesThe content of the following documents constitutes an indispensable clause of this document through normative references in the text. Among them, dated quotations Only the version corresponding to the date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to This document. GB/T 6005 Test sieve basic size of woven wire mesh, perforated plate and electroformed sheet GB/T 8170 Numerical rounding rules and the expression and determination of limit values3 Terms and definitionsThe following terms and definitions apply to this document. 3.1 Melting method A sample preparation method in which the sample is mixed with a certain proportion of mixed flux and an appropriate amount of release agent, and melted at a certain temperature to form a glass sample. 3.2 Tabletting method The sample is prepared with a boric acid edging substrate, or fixed with a plastic ring, etc., and pressed into a sample in a sample press. 3.3 Standardsample A set of samples with a known composition and content and a certain gradient used to draw the working curve, and the chemical composition and physical properties of the sample to be tested Consistent with other aspects. The composition content of the standard sample can cover the content range of quantitative analysis. [Source. GB/T 30905-2014, 3.4, with modification] 3.4 Driftcorrectionsample The sample used to correct the X-ray intensity drift of the instrument requires that its elemental analysis line has appropriate intensity and can be stable for a long time. [Source. GB/T 30905-2014, 3.3, with modification]4 PrincipleThe sample made by the melting method or the tableting method, through the X-ray tube to generate primary X-rays and irradiate the surface of the sample, resulting in the characteristics After the X-ray is split by the crystal, the detector measures the X-ray fluorescence intensity at the 2θ angle corresponding to the selected characteristic wavelength, according to the calibration curve ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 40915-2021_English be delivered?Answer: Upon your order, we will start to translate GB/T 40915-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 40915-2021_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 40915-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |