GB/T 37319-2019 English PDFUS$439.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 37319-2019: Energy-saving power supply equipment with inverter for lift Status: Valid
Basic dataStandard ID: GB/T 37319-2019 (GB/T37319-2019)Description (Translated English): Energy-saving power supply equipment with inverter for lift Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: K46 Classification of International Standard: 29.200 Word Count Estimation: 22,210 Date of Issue: 2019-03-25 Date of Implementation: 2019-10-01 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB/T 37319-2019: Energy-saving power supply equipment with inverter for lift---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Energy-saving power supply equipment with inverter for lift ICS 29.200 K46 National Standards of People's Republic of China Elevator energy-saving inverter power supply unit Published on.2019-03-25 2019-10-01 implementation State market supervision and administration China National Standardization Administration issued ContentForeword III 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Model specifications and basic parameters 3 4.1 Model Specifications 3 4.2 Basic parameters 3 5 Technical requirements 4 5.1 Environmental conditions 4 5.2 Mains input voltage and frequency 4 5.3 Output voltage and frequency in mains operation mode 4 5.4 Energy storage inverter operation mode and energy storage inverter operation time 5 5.5 Emergency Inverter Operation Mode 5 5.6 Automatic switching function 5 5.7 Protection function 6 5.8 shows 6 5.9 Comprehensive power saving rate 6 5.10 Efficiency 6 5.11 Noise 6 5.12 Security Requirements 6 5.13 Electromagnetic Compatibility 7 5.14 Appearance and Structure 7 6 Test method 8 6.1 Test conditions 8 6.2 Mains input voltage and frequency test 8 6.3 Output voltage and frequency test during mains operation mode 8 6.4 Energy storage inverter operation mode and energy storage inverter operation time test 8 6.5 Emergency Inverter Operation Test 10 6.6 Automatic switching function test 10 6.7 Protection function test 11 6.8 Display Function Check 11 6.9 Comprehensive power saving rate test 12 6.10 Efficiency measurement 13 6.11 Noise Measurement 13 6.12 Safety test 13 6.13 Electromagnetic Compatibility Test 14 6.14 Appearance and structure inspection 14 7 Inspection rules 14 7.1 Test item 14 7.2 Type test 14 7.3 Factory test 14 8 Marking, packaging, transportation and storage 15 8.1 Mark 15 8.2 Packing 16 8.3 Transportation 16 8.4 Storage 16ForewordThis standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard was proposed by the China Electrical Equipment Industry Association. This standard is under the jurisdiction of the National Power Electronics System and Equipment Standardization Technical Committee (SAC/TC60). This standard was drafted. Qingdao Chuangtong Technology Development Co., Ltd., Zhangzhou Kehua Technology Co., Ltd., Foshan City, Berel Electric Division Technology Co., Ltd., Foshan Xinguang Hongrui Power Equipment Co., Ltd., Qingdao Special Equipment Inspection and Testing Institute, Guangdong Zhicheng Champion Group Division, Zhuhai Titan Technology Co., Ltd., Wenzhou University, Foshan University of Science and Technology, Fuji Seiko Elevator (Qingdao) Co., Ltd. The main drafters of this standard. Yan Xueli, Su Xianjin, Yang Zhaohua, Feng Ningbo, Liu Yansheng, Li Minying, Pan Jingyi, Dai Yuxing, Yu Tao, Zhang Zhensheng, Yang Guodong, Zheng Chongwei. Elevator energy-saving inverter power supply unit1 ScopeThis standard specifies the terms and definitions of elevator energy-saving inverter power supply devices, model specifications and basic parameters, technical requirements, test methods, inspection Inspection rules, as well as marking, packaging, transportation and storage. This standard applies to elevator energy-saving inverter power supply devices (hereinafter referred to as power supply devices). This standard does not apply to the power supply unit of the elevator energy-saving inverter feedback grid.2 Normative referencesThe following documents are indispensable for the application of this document. For dated references, only the dated version applies to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 191 packaging storage and transportation icon GB/T 2900.33 Electrotechnical terminology power electronics technology GB/T 3859.1 General requirements for semiconductor converters and Grid-converters - Part 1-1. Basic requirements GB/T 3859.2 General requirements for semiconductor converters and grid converters - Part 1-2. Application guidelines GB/T 4208 enclosure protection grade (IP code) GB/T 7024-2008 Elevator, escalator, moving walkway terminology GB/T 7251.1-2013 Low-voltage switchgear and control equipment - Part 1. General GB 7588 Elevator Manufacturing and Installation Safety Specification GB/T 10058-2009 Elevator technical conditions GB/T 13422-2013 Semiconductor converter electrical test method GB/T 14048.1-2012 Low-voltage switchgear and control equipment - Part 1. General GB/T 21225-2007 Inverter emergency power supply3 Terms and definitionsGB/T 2900.33, GB/T 3859.1, GB/T 3859.2, GB/T 7024-2008, GB 7588 and GB/T 21225-2007 The following terms and definitions apply to this document. For ease of use, some of the GB/T 7024-2008 are listed below. Terms and definitions. 3.1 The regenerative electric energy generated by the elevator operation is recovered and stored, and the stored electric energy is inverted into a three-phase power frequency sine wave alternating current that meets the requirements. A matching device for powering the elevator. Note. The power supply unit can not only reduce the mains consumption (energy saving) of the elevator, but also ensure that the elevator continues to operate safely after the mains supply is interrupted or failed. 3.2 Elevator lift Serving a number of specific floors within a building, the car operating in at least two columns perpendicular to the horizontal plane or at an oblique angle to the lead line is less than Permanent transport equipment for 15° rigid orbital motion. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 37319-2019_English be delivered?Answer: Upon your order, we will start to translate GB/T 37319-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 37319-2019_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 37319-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |