GB/T 37227.1-2018 English PDFUS$199.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 37227.1-2018: Evaluation method and testing method for energy performance of refrigerating systems -- Part 1: Energy-storage air conditioning systems Status: Valid
Basic dataStandard ID: GB/T 37227.1-2018 (GB/T37227.1-2018)Description (Translated English): Evaluation method and testing method for energy performance of refrigerating systems -- Part 1: Energy-storage air conditioning systems Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: F01 Classification of International Standard: 27.010 Word Count Estimation: 10,193 Date of Issue: 2018-12-28 Date of Implementation: 2019-07-01 Regulation (derived from): National Standard Announcement No. 17 of 2018 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB/T 37227.1-2018: Evaluation method and testing method for energy performance of refrigerating systems -- Part 1: Energy-storage air conditioning systems---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Evaluation method and testing method for energy performance of refrigerating systems--Part 1. Energy--storage air conditioning systems ICS 27.010 F01 National Standards of People's Republic of China Refrigeration system performance evaluation and calculation test method Part 1. Energy storage air conditioning system refrigeratingsystems-Part 1.Energy-storageairconditioningsystems Published on.2018-12-28 2019-07-01 implementation State market supervision and administration China National Standardization Administration issued ContentForeword I 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Basic requirements 2 5 Performance Evaluation 2 6 test calculation method 4ForewordGB/T 37227 "Refrigeration System Performance Evaluation and Calculation Test Method" is divided into the following five parts. --- Part 1. Energy storage air conditioning system; --- Part 2. Multi-energy complementary heating and air conditioning systems; --- Part 3. supermarket refrigeration system; --- Part 4. Heat pump systems based on low grade thermal energy utilization; --- Part 5. VOCs recycling refrigeration system. This part is the first part of GB/T 37227. This part is drafted according to the rules given in GB/T 1.1-2009. This part is proposed and managed by the National Energy System Standardization Technical Committee (SAC/TC459). This section drafted by. Zhuhai Gree Electric Co., Ltd., China National Institute of Standardization, China Architecture Northwest Design and Research Institute Limited Company, Tsinghua University, Architectural Design and Research Institute of South China University of Technology, Tianjin Architectural Design Institute, Beijing Architectural Design and Research Institute Co., Ltd. Zhuhai Hengqin Energy Development Co., Ltd., Beijing Zhongkengtong Quality Certification Center Co., Ltd., Hangzhou Yuanpai Technology Co., Ltd., York (China) Trading Co., Ltd., Liaoyuan Cold & Heat System (China) Co., Ltd., McQuay Air Conditioning Refrigeration (Wuhan) Co., Ltd. The main drafters of this section. Liu Hua, Cheng Jianhong, Zhou Min, Wei Qingyi, Wang Wei, Wu Xiaoting, Zhang Jie, Chen Jin, Li Yong, Guo Yong, Liu Meng, Ye Shuiquan, Ken Dingli, Zhao Wei, Zhuo Peijun. Refrigeration system performance evaluation and calculation test method Part 1. Energy storage air conditioning system1 ScopeThis part of GB/T 37227 specifies the terms, basic requirements and performance evaluation methods of air conditioning and refrigeration systems using energy storage technology. Laws, tests and calculation methods, etc., in which performance evaluation is carried out in terms of energy efficiency and economy. This section applies to various types of energy storage air conditioning systems, such as ice storage and water storage, which are designed to store and store cold cycles on a daily basis, including cold storage and Refrigeration chiller, cold storage circulating pump, cooling circulation pump, cooling circulation pump, cooling pump and cold running in cold storage, cooling, cooling, etc. But the tower fan and so on. Does not include the end fan of the air conditioning system. This standard is not applicable to air-cooled refrigeration units.2 Normative referencesThe following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 7778-2017 refrigerant numbering method and safety classification GB/T 10870-2014 Vapor compression cycle cold water (heat pump) unit performance test method GB/T 17758-2010 unit air conditioner GB/T 17981-2007 Economical operation of air conditioning systems GB/T 18430.1-2007 Vapor compression cycle cold water (heat pump) units - Part 1 . Cold for industrial or commercial use Water (heat pump) unit GB/T 19412-2003 Test and evaluation method for cold storage air conditioning system GB 25131-2010 Vapor compression cycle cold water (heat pump) unit safety requirements GB/T 26194-2010 Cooling system performance test method JGJ158-2008 Technical Specifications for Cold Storage Air Conditioning Engineering3 Terms and definitionsGB/T 19412-2003, GB/T 17981-2007, GB/T 26194-2010 and JGJ158-2008 as defined by the following Terms and definitions apply to this document. 3.1 Designing the energy performance of the cold storage air conditioning system in the storage and cooling cycle. energy performanceofenergy-storageaircondi- Tioningsystemsduringdesignedcyclicalperiod A design of the storage and cooling cycle (usually 24h), the sum of the input energy (usually electricity) of the cold storage air conditioning system, and the cold storage during the same period The ratio of the total cooling capacity of the air conditioning system. Note. The unit is kWh/kWhc per kWh of electricity. 3.2 Typical day condition usuallyday'scondition In the outdoor weather conditions close to the local summer air-conditioning design, when the cold storage air-conditioning system is normally stored and discharged, it can be tested in the field by cold storage. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 37227.1-2018_English be delivered?Answer: Upon your order, we will start to translate GB/T 37227.1-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 37227.1-2018_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 37227.1-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |