GB/T 36422-2018 English PDFUS$119.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 36422-2018: Man-made fiber -- Test method for micro morphology and diameter -- Scanning electron microscope method Status: Valid
Basic dataStandard ID: GB/T 36422-2018 (GB/T36422-2018)Description (Translated English): Man-made fiber -- Test method for micro morphology and diameter -- Scanning electron microscope method Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: W50 Classification of International Standard: 59.060.20 Word Count Estimation: 6,623 Date of Issue: 2018-06-07 Date of Implementation: 2019-01-01 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB/T 36422-2018: Man-made fiber -- Test method for micro morphology and diameter -- Scanning electron microscope method---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Man-made fiber--Test method for micro morphology and diameter--Scanning electron microscope method ICS 59.060.20 W50 National Standards of People's Republic of China Determination of microscopic morphology and diameter of chemical fibers Scanning electron microscopy Published on.2018-06-07 2019-01-01 implementation State market supervision and administration China National Standardization Administration issued ForewordThis standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard is proposed and managed by the China National Textile and Apparel Council. This standard was drafted. Guangzhou Fiber Products Testing and Research Institute, Shanghai Textile Industry Technology Supervision Institute, Shanghai Textile Group Testing Standard Co., Ltd., Xiamen Xianglu Chemical Fiber Co., Ltd., Sinopec Yizheng Chemical Fiber Co., Ltd., Shanghai Quality Supervision and Inspection Technology Research Research Institute, Qingdao Zhifa Group Co., Ltd., China Chemical Fiber Industry Association, South China University of Technology. The main drafters of this standard. Nie Fengming, Zhu Ruiqi, Li Hongjie, Zhang Wenzhao, Liu Longmin, Chen Jianmei, Li Ying, Wan Guozhen, Wan Lei, Yan Yurong. Determination of microscopic morphology and diameter of chemical fibers Scanning electron microscopy1 ScopeThis standard specifies the use of scanning electron microscopy to observe the microscopic morphology of chemical fibers and test the fiber diameter. method. This standard is applicable to the determination of the microscopic morphology and diameter of various chemical fibers and their products. The determination of the diameter is only applicable to the fiber transverse Chemical fibers with a circular or nearly circular cross section, other materials may be implemented in accordance with this standard.2 Normative referencesThe following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. Textiles and textiles - Performance and test terms - Part 1. Fibres and yarns GB/T 3291.3 Textiles and textile materials - Performance and test terms - Part 3 GB/T 4146 (all parts) Textile chemical fiber GB/T 8170 Numerical Rounding Rules and Representation and Determination of Limit Values3 Terms and definitionsThe terms and definitions defined in GB/T 3291.1, GB/T 3291.3, GB/T 4146 (all parts) apply to this document.4 PrincipleScanning electron microscopy focused, electron beam with a certain energy is scanned on the surface of the fiber sample to excite it from the surface of the sample Secondary electrons, after the secondary electrons are collected and processed, a scanned image of the surface topography of the sample can be obtained, and the microscopic morphology of the sample can be observed. The diameter of the fiber was measured by measuring the distance between the two edges of the longitudinal side of the individual fibers on the image. 5 instruments, tools and materials Instruments, tools and materials include. a) Scanned electron microscope that has been calibrated or calibrated. the resolution of the secondary electronic image is better than 20 nm, and the magnification is at least 30 times~ 20000 times; b) vacuum spray or sputter; c) Hastelloy slicers or other types of fiber cutters; d) scorpions, scissors, ear balls; e) copper or aluminum sample holders; f) conductive adhesive; g) Gold. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 36422-2018_English be delivered?Answer: Upon your order, we will start to translate GB/T 36422-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 36422-2018_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 36422-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |