GB/T 34067.2-2019 PDF EnglishUS$130.00 · In stock · Download in 9 seconds
GB/T 34067.2-2019: In-home display terminal for smart-utilization power - Part 2: Data exchange Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid
Similar standardsGB/T 34067.2-2019: In-home display terminal for smart-utilization power - Part 2: Data exchange---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT34067.2-2019NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 17.220.20 N 22 In-home display terminal for smart-utilization power - Part 2: Data exchange ISSUED ON: MAY 10, 2019 IMPLEMENTED ON: DECEMBER 01, 2019 Issued by: State Administration for Market Regulation; Standardization Administration of the People’s Republic of China. Table of ContentsForeword ... 3 1 Scope ... 4 2 Normative references ... 4 3 Terms and definitions ... 5 4 Data exchange model ... 6 5 Data exchange based on RS-485 communication interface ... 7 6 Low-voltage power line narrow-band carrier communication technical requirements ... 7 7 Short-range wireless communication technical requirements ... 7 8 Wireless public network communication interface technical requirements ... 7 9 Data transmission requirements ... 8 Appendix A (Informative) Schematic diagram of in-home display terminal for smart-utilization power and smart energy meter data exchange ... 9 In-home display terminal for smart-utilization power - Part 2: Data exchange1 ScopeThis Part of GB/T 34067 specifies the data exchange model of in-home display terminal for smart-utilization power (hereinafter referred to as terminal), and specifications of local connection data exchange, Local Area Network (LAN) data exchange, Wide Area Network (WAN) data exchange which are based on RS485 communication interface, short-range wireless communication interface, low-voltage power line narrow-band carrier communication interface and GPRS public network communication interface. This Part applies to terminal equipment that is used in-home to display power consumption information by communication.2 Normative referencesThe following documents are indispensable for the application of this document. For dated references, only the dated version applies to this document. For undated references, the latest edition (including all amendments) applies to this document. GB/T 9387.1-1998, Information technology. Open Systems Interconnection. Basic Reference Model. Part 1: The Basic Model GB/T 17215.101-2010, Electricity metering. Data exchange for meter reading, tariff and load control. Glossary of terms. Part 1: Terms related to data exchange with metering equipment using DLMS/COSEM GB/T 19882.31-2007, Automatic meter reading system. Part 3-1: Application layer data exchange protocols. Object identification system GB/T 19882.32-2007, Automatic meter reading system. Part 3-2: Application layer data exchange protocols. Interface class GB/T 19882.33-2007, Automatic meter reading system. Part 3-3: Application layer data exchange protocols. COSEM application layer GB/T 19882.222-2017, Automatic meter reading system. Part 222: Physical layer (PHY) specifications. Wireless communication meter reading system GB/T 19882.223-2017, Automatic meter reading system. Part 223: Data link layer (MAC sub-layer). Wireless communication meter reading system GB/T 19897.1-2005, Automatic meter reading system lower layer communication protocol. Part 1: direct local data exchange GB/T 26831.1-2010, Society energy metering for reading system specification. Part 1: Data exchange GB/T 26831.4-2017, Specification for reading system of energy metering in community. Part 4: Wireless meter readout GB/T 26831.5-2017, Specification for reading system of energy metering in community. Part 5: Wireless relaying GB/T 31983.11-2015, Narrow band power line communication over low- voltage mains. Part 11: 3 kHz to 500 kHz frequency bands and classifications, limits of output level and electromagnetic disturbances GB/T 31983.31-2017, Narrow band power line communication over low- voltage mains. Part 31: Narrow band orthogonal frequency division multiplexing power line. Communication physical layer specification GB/T 34067.1-2017, In-home display terminal for smart-utilization power. Part 1: General technical requirements DL/T 645-2007, Multi-function watt-hour meter communication protocol DL/T 698.35-2010, Data acquisition and management system for electrical energy. Part 3-5: Technical specification of electrical energy data acquisition terminal. Special requirement for meter rending terminal of LV customers DL/T 698.45-2017, Data acquisition and management system for electrical energy. Part 4-5: Communication protocol-object oriented data exchange protocol YD/T 1208-2002, 800MHz CDMA digital cellular mobile communication network Wireless Intelligence Network (WIN). Phase 1: Technical specification of interface YD/T 1214-2006, Technical requirement of 900/1800MHz TDMA Digital Cellular Mobile Telecommunication Network General Packet Radio Service (GPRS). Equipment: Mobile Stations3 Terms and definitionsTerms and definitions determined by GB/T 17215.101-2010, GB/T 19897.1- 2005 and GB/T 34067.1-2017, and the following ones are applicable to this document. The application layer supports GB/T 19882.31-2007, GB/T 19882.32-2007, GB/T 19882.33-2007, GB/T 26831.1-2010, DL/T 645-2007 and DL/T 698.45- 2017. Refer to Appendix A for in-home display terminal for smart-utilization power and smart energy meter data exchange.5 Data exchange based on RS-485 communicationinterface The interface is a RS-485 communication interface of the two-wire configuration (A, B); it shall comply with the provisions of 4.6.3 of DL/T 698.35-2010. When it is used for local connection data exchange, the terminal is connected by the main unit. When it is used for Local Area Network (LAN) data exchange, the terminal is connected by the slave unit. 6 Low-voltage power line narrow-band carrier communication technical requirements It shall comply with the provisions of GB/T 31983.11-2015, and GB/T 31983.31- 2017.7 Short-range wireless communication technicalrequirements It shall comply with the provisions of GB/T 26831.4-2017, GB/T 26831.5-2017, GB/T 19882.222-2017, and GB/T 19882.223-2017.8 Wireless public network communication interfacetechnical requirements It shall comply with corresponding national standards or industry standards. The use of CDMA interfaces shall comply with the provisions of YD/T 1208- 2002. The use of TDMA interfaces shall comply with the provisions of YD/T 1214-2006. ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of GB/T 34067.2-2019 be delivered?Answer: The full copy PDF of English version of GB/T 34067.2-2019 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of GB/T 34067.2-2019_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 34067.2-2019_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 34067.2-2019 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.How to buy and download a true PDF of English version of GB/T 34067.2-2019?A step-by-step guide to download PDF of GB/T 34067.2-2019_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "GB/T 34067.2-2019". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |