GB/T 32710.5-2016 English PDFUS$619.00 ยท In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 32710.5-2016: Safety requirements for environmental testing and conditioning equipment -- Part 5: Heating baths Status: Valid
Basic dataStandard ID: GB/T 32710.5-2016 (GB/T32710.5-2016)Description (Translated English): Safety requirements for environmental testing and conditioning equipment -- Part 5: Heating baths Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: N61 Classification of International Standard: 19.040 Word Count Estimation: 31,341 Date of Issue: 2016-06-14 Date of Implementation: 2017-01-01 Quoted Standard: GB 4208-2008; GB 4706.1-2005; GB 4706.71-2008; GB 4706.89-2008; GB 4793.1-2007; GB/T 5465.2-2008; GB 17465.1; GB 17465.2; GB 17465.3; GB 17465.4; GB/T 32710.1-2016; ISO 7000-2004; ISO 7010-2011; IEC 61770-2008 Regulation (derived from): National Standard Announcement No. 8 of 2016 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the effects of electrical shock and electrical burns, mechanical hazards, flame spread from inside and outside of the equipment, overtemperature, fluid and fluid pressure, radiation effects (including lasers, sound pressure) in the high temperature thermostat bath for measurement, control and laboratory use And ultrasonic pressure), the release of gases, explosions and implosion, as well as the safety of biological and chemical hazards. (EMC) requirements, protective measures against explosive atmospheres, repairs (repairs), and maintenance (repairs) of persons who do not include the reliability, performance, or other characteristics of the non-safety-related equipment, the effectiveness of the shipping package. This standard applies to the measurement, control and laboratory use of high-temperature thermostat bath. GB/T 32710.5-2016: Safety requirements for environmental testing and conditioning equipment -- Part 5: Heating baths---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Safety requirements for environmental testing and conditioning equipment.Part 5. Heating baths ICS 19.040 N61 National Standards of People's Republic of China Environmental testing equipment and equipment safety regulations Part 5. high temperature thermostat bath Part 5. Heatingbaths 2016-06-14 release 2017-01-01 Implementation General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China China National Standardization Management Committee released Directory Preface I 1 Scope 1 2 normative reference document 1 3 Terms and definitions 1 4 Test 4 5 logo and document 7 6 anti-shock 14 7 Anti-mechanical hazard 18 8 Resistance to mechanical shock and impact9 to prevent the spread of flame 19 10 Equipment temperature limits and heat resistance 20 11 Risk of fluid protection 12 Radiation protection (including laser source), sound pressure and ultrasonic pressure 23 13 Protection against the release of gases, explosions and implosion 14 components 24 15 Protection of interlocking equipment 25 Test and Measurement Equipment Appendix 26 Reference 27ForewordGB/T 32710 based on GB/T 32710.1-2016 "Environmental testing equipment and equipment safety regulations Part 1. General" GB 4793.1-2007 "Safety requirements for electrical equipment for measurement, control and laboratory use Part 1. General requirements" To develop. GB/T 32710 "Environmental testing equipment and equipment safety regulations" is divided into 13 parts. - Part 1. General; - Part 2. cryogenic temperature cycling devices; - Part 3. low temperature thermostat bath; - Part 4. High temperature thermostatic circulation devices; - Part 5. High temperature thermostat bath; - Part 6. Biological artificial climate chamber; - Part 7. Climate and Environmental Test Chamber; - Part 8. Biochemical incubator; - Part 9. Thermostat incubator; Part 10. electric drying oven and electric blast drying oven; - Part 11. Air heat aging test chamber; - Part 12. Salt tank; - Part 13. Oscillators, oscillating thermostat tanks and oscillating incubators. This part is part 5 of GB/T 32710. This part is drafted in accordance with the rules given in GB/T 1.1-2009. GB/T 32710.5 should be used in conjunction with GB/T 32710.1-2016 and GB 4793.1-2007. This section states that "applicable" , The corresponding strip of GB 4793.1-2007 shall be applied to this part; this section states that the words "substitute" or "modification" The provisions of this section "increase" part, indicating that in addition to meet the corresponding provisions of GB 4793.1-2007, but also in line with the Department Increase the number of points. In order to distinguish between GB 4793.1-2007, the number of the added section of this section begins at 101, for example 5.2.101, aa), bb) and so on. This part is made by the China Machinery Industry Federation. This part of the National Laboratory Equipment and Equipment Standardization Technical Committee (SAC/TC526) centralized. This part of the main drafting unit. Hangzhou snow in the temperature Technology Co., Ltd., Wuxi South Jiangsu Experimental Equipment Co., Ltd., Anhui Province, Research Institute, Machinery Industry Instrument Integrated Technology and Economic Research Institute, China Testing Technology Co., Ltd. The main drafters of this part. Xu Yueming, Ni Yiming, Jin Meifeng, Zhang Guiling, He Gangjian, Li Siyuan. Environmental testing equipment and equipment safety regulations Part 5. high temperature thermostat bath1 ScopeThis part of GB/T 32710 specifies the electrical shock and electrical burns in the measurement, control and laboratory use of high temperature thermostats, mechanical hazards, The flame spreads out of the device, over temperature, fluid and fluid pressure effects, radiation effects (including lasers, sound pressure and ultrasonic pressure), release Gas, explosion and implosion, as well as biological and chemical hazards. But does not include the reliability, performance or reliability of devices that are not related to safety Other features, the effectiveness of transport packaging, electromagnetic compatibility (EMC) requirements, protection against explosive atmospheres, maintenance (repair), repair (repair) Personnel protection. Note 1. This part applies when the device consisting of the immersion thermostatic unit and the open container does not have an external circulation function. Note 2. applied to the industrial site, both within the scope of this part of the industrial automation products and should also meet the industrial automation products related standards Claim. This part is suitable for measuring, control and laboratory with high temperature thermostat. Note 3. Such instruments and equipment can also be used outside the laboratory, such as high temperature thermostats for industrial processes.2 normative reference documentsThe following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. GB 4208-2008 enclosure protection class (IP code) Safety of household and similar electrical appliances - Part 1. General requirements GB 4706.1-2005 GB 4706.71-2008 Safety and water supply installations for household and similar electrical appliances - Particular requirements for fixed circulation pumps GB 4706.89-2008 Safety of household and similar electrical appliances Industrial and commercial high pressure cleaners and steam cleaners Claim GB 4793.1-2007 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1. General requirements Graphical symbols for use in electrical equipment - Part 2. Graphical symbols ISO /TS 545 Technical Corrigendum GB 17465 (all parts) Couplers for household and similar use Safety code for environmental testing equipment and equipment - Part 1. General principles GB/T 32710.1-2016 ISO 7000..2004 Graphical symbols for equipment and a list (Graphicalsymbolsforuseonequipment- Indexandsynopsis) ISO 7010..2011 Drawings Symbols Safety colors and safety symbols Workplace and public places use safety symbols (Graphical symbols-Safetycolorsandsafetysigns-safetysignsusedinworkplacesandpublicareas) IEC 61770..2008 Electrical appliances connected to manifolds Avoiding anti-siphon and failure of hose assemblies (Electricappliances connectedtothewatermains-Avoidanceofbacksiphonageandfailureofhose-sets3 terms and definitionsGB 4793.1-2007 Definitions and the following terms and definitions apply to this document. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 32710.5-2016_English be delivered?Answer: Upon your order, we will start to translate GB/T 32710.5-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 32710.5-2016_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 32710.5-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |